Charging Pile Instructions-V2.0
5
wire system
7
Rated Input Current
30kW
47
A
Input 400 VAC, each phase
with full load
40kW
62
45kW
70
60kW
93
75kW
117
80kW
124
90kW
140
100kW
156
120kW
187
140kW
218
150kW
233
160kW
249
5.2 Output characteristics
No.
Item
Technical
requirements
Unit
Remark
1
Voltage error
≤±0.5
%
2
Current error
≤±1
%
Output DC current ≥ 30A
≤±1
A
Output DC current
<
30A
3
Stabilized voltage precision
≤±0.5
%
4
Stabilized current precision
≤
±
1
%
5
Ripple factor
Xrms
≤
1
Xpp
≤
1
%
6
Current Ripple
1.5
A
f
≤
10Hz
6
f
≤
5000Hz
9
f
≤
150000Hz
7
Efficiency
≥
93
%
10-30% of output power
≥
94
31-40% of output power
≥
95
41-60% of output power
≥
94
61-100% of output power
8
Current sharing unbalance
≤±5
%
No less than 4 modules
together50% and above load
9
Current control time
≥
20
A/s
10
Current stopping rate
≥
100
A/s