SAFETY INFORMATION 

General: 

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety. 

 

For the protection of young children, install an effective fire safety screen around your fire. Always keep 
children well away from the wood burner when it is alight. 

 

Supervise young children to ensure they do not play with the appliance. 

 

During initial burns of the appliance, ventilate the rooms well. It is recommended that babies, small 
children, pregnant women and pets should not be present in the area during initial burns as this is the 
firebox paint curing period. 

 

Do not make any modifications to the unit, and use it only in the manner described in the manual. Using it 
in any manner not recommended by the manufacturer may result in injury or death. 

For units including electrical connections: 

 

If the wood burner is permanently connected to an electrical source, an isolating switch (wall switch) must 
be installed. 

 

New circuits or modifications, if required, but be made using the services of a certified electrician only. 

 

Ensure that the outlets you use are grounded properly, polarised and provided with fuse units. 

 

Ensure that the electrical plug is accessible after installation. The wood burner must not be located 
immediately below an electrical socket. 

 

Never operate the appliance with a damaged plug or cord, or if you observe the fan unit is malfunctioning 
or the heater has been damaged in any way. Call the authorised service person immediately for repairs or 
making electrical or mechanical adjustments. 

– Isolate the electrical supply in order to alleviate any 

potential risk. 

 

If the supply cord is damaged, the manufacturer, its service agent or a suitably qualified person must 
replace it in order to avoid electrical hazard. Any cord similar to the original can be used. 

IMPORTANT INFORMATION 

 

I. 

It is imperative that you familiarise yourself with this entire document, and also ensure you have 
sufficient knowledge of relevant building regulations prior to proceeding with an installation. 

II. 

The appliance and flue system shall be installed in compliance with AS/NZS 2918:2001 and the 
appropriate requirements of the relevant building code or codes. 

III. 

Appliances installed in accordance with this standard shall comply with the requirements of 
AS/NZS 4013 where required by the regulatory authority i.e. the appliance shall be identifiable by 
a compliance plate with the marking 

“tested to AS/NZS 4013” 

IV. 

Any modification of the appliance that has not been approved in writing by the testing authority 
is considered to be in breach of the approval granted for compliance with AS/NZS 4013 

V. 

Mixing of appliance or flue system components from different sources or modifying the 
dimensional specification of components may result in hazardous conditions. Where such action 
is considered, the manufacturer should be consulted in the first instance. 

VI. 

Cracked and broken components e.g. glass panels or fire bricks, may render the installation 
unsafe. 

 

 

 

 

Summary of Contents for XANDER INSERT

Page 1: ... division of Terry Young Ltd New Zealand INSTALLATION INSTRUCTIONS for XANDER INSERT WOOD BURNER Clean Air Sub 1 0 Non Clean Air Rural 26 JUNE 2017 These instructions are for MASONRY installations only For Built In ZC installations please refer to the separate instruction book ...

Page 2: ...elow an electrical socket Never operate the appliance with a damaged plug or cord or if you observe the fan unit is malfunctioning or the heater has been damaged in any way Call the authorised service person immediately for repairs or making electrical or mechanical adjustments Isolate the electrical supply in order to alleviate any potential risk If the supply cord is damaged the manufacturer its...

Page 3: ...scia 207mm either side of the outer casing of the firebox Fig 5 E2 No heat sensitive material is permitted to contact the fascia forming or surrounding the front of the installation E3 Inside the cavity no combustible material is to be placed any closer to the outer casing of the firebox than 600mm from the top 20mm from either side or 20mm from the rear E4 Where a nogging or lintel is required a ...

Page 4: ... I Cavity Venting I1 A 10 000mm vent must be installed at least 600mm from the base of the enclosure This can be any configuration as long as it equates to at least 10 000mm For example 2 holes at 50 x 50mm or 1 hole at 100 x 100mm I2 Similar vent s can also be added to the top of the masonry enclosure however the venting already provided via the flue cone and liner will be sufficient without this...

Page 5: ...Please Note All flue joints must be sealed with flue sealing compound Use stainless steel screws or rivets to join the flue pipe three equally spaced places at each joint The first length of flue must be fixed to the flue spigot with at least one stainless steel screw or rivet The required minimum flue termination height is 4 6 metres above the floor protector K Typical Masonry Flue Installation F...

Page 6: ...crease from 1000 min until clear within 3000 of flue top L Conditions for Flues Fig 4 L1 The FLUE shall extend to Not less than 600mm above the highest point on the roof if within 3 0m of that point or Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3 0m In any case the length of the flue shall not be less than 4 6m from the ash floor...

Page 7: ...Install Xander_Insert_MASONRY 2017 06 26 doc www yunca co nz Page 7 of 12 M Xander Masonry Installation Thermal Clearances THERMAL CLEARANCES FRONT VIEW THERMAL CLEARANCES CROSS SECTIONS Fig 5 Fig 6 ...

Page 8: ...00 300 O Xander Insert Seismic Fixings Follow local Council s specifications Prior to installation ensure the cavity floor is levelled Also ensure the mantel face is perpendicular in relationship to the cavity floor Ensure the unit is securely fixed using sleeve anchors or similar at the locations shown in the images on this page Fig 7 P Xander Flue Spigot Fixing Fig 8 Note Access to affix the flu...

Page 9: ... any way Q3 Blanket should be fastened to the outer casing in such a way that secure long term fitment is assured For example using a high temperature multipurpose adhesive or screws and panel washers CAUTION Before installing the fascia ensure the thermal blanket completely surrounds the top sides and back of the firebox with the exception of the rear air intake and that there will be no gaps bet...

Page 10: ...re taken within the cavity to allow for this R2 Although the fan is controlled automatically by a thermostat it is recommended that an isolator switch is installed in conjunction WARNING Ensure the fan is wired by a registered electrician in compliance with all local regulations INSTALLATION TYPE FAN SWITCH CABLE POWER CORD ENTRY A B TO BE ADDED TO ELEVATION MASONRY 103 48 Fig 10 ...

Page 11: ...ether S4 Mount the Fan unit and hearth to the fascia Fig 14 by securing the two screws as shown WARNING When mounting the panel and fan assembly any excess cabling including the 4 pole connector should be situated in the cavity outside of the firebox outer casing and not in the high temperature area under the firebox S5 Ensure all electrical connections are secure and suitably tested to applicable...

Page 12: ... yunca co nz Page 12 of 12 END Fig 15 Factory wired fascia circuit box Fig 16 Hard wired fascia circuit box These instructions spare parts information operation and maintenance guides may be downloaded from http www yunca co nz installation operation ...

Reviews: