9. It is now possible to remove the entire main burner module.
10. This will expose the pilot assembly and make it possible to disconnect the gas supply
to the pilot burner
11. When the brass nut is removed from the base of the pilot burner the pilot jet will drop
out. Insert new pilot jet from conversion kit ensuring the chamfered end is facing
upwards.
12. The gas can now be reconnected to the pilot and the burner module replaced and
reconnected.
13. When changing from N.G. to LPG, the in line restrictor, located in the rear burner
pipe where it attaches to the control, must me removed. When changing from LPG to
NG, this restrictor must be placed in rear burner pipe at the control.
14. The brass reducer that couples the front burner pipe to the control must also be
changed and the reducer supplied with kit fitted.
15. Test all connections for gas tightness and replace logs and door.
16. Update or replace appliance data plate for new specifications and gas type.