Fault Finding:
SYMPTOM
PROBLEM
CORRECTIVE
Pilot Will Not Light.
No spark at pilot burner.
Check connection between
electrode in pilot assembly
and lead from control. Press
connection hard together.
(Inserted 18mm in to control)
Replace the pilot assembly if
ceramic insulator is cracked or
broken. (Finger tighten nut
that holds ceramic insulator)
Gas not available at the spark
point. A complete ring of gas
around the pilot hood.
Clean the gas ways of soot or
foreign particles
Open up the gas gap where the
spark earth’s on to the pilot.
Spark gap is incorrect.
Spark gap should be 3-4mm
between the electrode tip and
the pilot flame hood.
No gas at pilot burner
Check that isolating valves
are turned on and gas is
available.
Check pilot hood for
blockage
Remove pilot jet and blow
clean. The jet is located
inside the base of the pilot
burner and is removed by
disconnecting the gas to the
pilot and removing the brass
nut from the base of the
burner. Jet will fall out.
Check for any obstructions in
the gas line that may cause
low pressure or restrict flow.
Purge gas lines.
No Supply Gas.
L.P.G. -- Refill tank
Natural -- Check with gas
supplier