![Yunca Gas EROS User Manual Download Page 18](http://html.mh-extra.com/html/yunca-gas/eros/eros_user-manual_915832018.webp)
25-07-01
Page 18 of 23 Operation Instructions for Eros Free Standing Gas Fire July 2001.doc
top 8mm of the thermocouple.
Thermocouple not properly
connected.
Check back of main control
where thermocouples copper
tube enters the control.
Tighten brass collar nut.
Defective thermocouple.
Replace thermocouple
A new thermocouple may be
ordered through your
YUNCA agent.
Faulty control valve.
A replacement may be fitted
by a suitably qualified
service person.
Pilot burning, no gas to
burners
Control turned to Pilot only
Turn the control knob to on
position
Thermostat turned down
below the room temperature
Turn the thermostat up to a
setting above room
temperature.
Move the thermostat bulb to
a position that accurately
senses the room temperature
Burner injectors may be
blocked.
Disconnect gas supply at
burners and unscrew brass
injectors from end of burner.
Use compressed air to clean
out orifice.
Back burner stays on when
switched to off position.
Faulty control
Control requires replacement.
Build up on the control
valve.
Disassemble the control
valve by removing the two
screws below the cover.
Extract the control valve,
note the position. Clean the
control valve clean and re-
assemble. Test operation.