16-02-05 Page 4 of 19 Operation Instructions for Electronic InBuilt EIB 2002
INSTALLATION
Considerations
The most desirable and beneficial location for a YUNCA ELECTRONIC INBUILT HEATER is in the
centre of a building, thereby allowing the most efficient use of the heat created.
The location of windows, doors and the traffic flow in the room where the heater is to be located,
should all be considered.
To obtain maximum heat distribution with any heater a ceiling fan can be fitted.
Another important consideration when installing the Yunca ELECTRONIC INBUILT is availability
of power supply to the fan and plumbing of gas line.
When the appropriate position has been selected, the unit can be inserted into the prepared cavity that
includes a level base. The fire shall be attached via bolt holes to the floor to ensure that the unit remains
secure in the event of an earthquake or similar.
If the heater is being attached to a concrete floor dyna bolts should be used, if the floor is wooden the
bolts used should be long enough to go fully through the floorboards and fixed with nuts and washers
from the underside.
The earthquake brackets are located at the front corners of the heater and are exposed by removing the
hearth.