16-02-05 Page 12 of 19 Operation Instructions for Electronic InBuilt EIB 2002
MAINTENANCE
A qualified service person recommended by your YUNCA dealer should conduct an annual inspection
and undertake any maintenance required on your YUNCA ELECTRONIC INBUILT. Its venting and
installation must be checked to keep it running safely and efficiently. The following procedures should
be performed only by a qualified service person. The gas supply and electrical power should be isolated
whenever any maintenance procedures are undertaken.
Note: the front glass can only be removed after the heater has been turned off for long enough
that the door has cooled to touching temperature.
REMOVING THE FRONT DOOR.
Cleaning The Log Set And Firebox.
During the annual inspection and maintenance appointment, the service person should clean dust, lint
and any light soot accumulation from the logs and the fire box area. An extra soft brush should be used
on the logs as they are extremely fragile. If at any time the logs cannot be removed or installed without
force, the cause must be found. The logs must never be forced.
Procedure,
1. Remove front door as described previously
2. Remove the front log set from the firebox by lifting it up and out. Brush it gently over a newspaper
and carefully place it out of the way.
3. Remove the back log and clean it in the same way.
4. The bark tray can be removed by lifting and pulling it straight out, with the bark still on it.
5. The bark consists of a mixture of vermiculite and composite chips and it can be dusted by sieving.
If needed a replacement bag can be ordered through your YUNCA dealer.
(See parts list for reference number)