ELECTRIC WIRING
All electrical wiring must be done in accordance with the
National Electrical Code. The code needs to be legally
authorized in the area where the installation is being
made. The circuit protector device must be located in a
convenient place near the furnace. No lighter than
14 AWG wire should be used in the furnace power
supply circuit. All furnaces covered by this manual and
installed in the United States of America operate on
115 Volts, 60 Cycle, 1-Phase Alternating Current with a
20 amp circuit protector device.
WARNING
:
Turn off electric power at
circuit protector device before making
any line voltage connections.
WIRING THE FURNACE
The furnace wiring is provided in harness form.
Mount the 4 x 4 junction box on 7/8” diameter opening
on front of blower compartment
.
Secure with conduit
connector and locknut. For the blower motor, secure
with lead conduit and at least one screw. Connect
components as shown in wiring diagrams.
See Fig 23.
CAUTION
:
This furnace is not approved
for use with aluminum wire.
NOTE
:
24 volt wires from the transformer to DS-103
damper control, from burner to DS-103
damper control, and from thermostat to
DS-103 damper control need not be
enclosed in conduit unless required by local
codes.
DS-103 DAMPER CONTROL
The T&T terminals are connected to the T&T terminals
on the gas or oil burner. The R terminal is not used.
The C terminal is connected to the C terminal on the
24-volt transformer. Terminal 1 is connected to the
wood/coal thermostat (smaller stat). Terminal 2 is
connected to the burner thermostat (larger stat). When
Terminal 1 is energized by the wood/coal thermostat, a
relay on the circuit board energizes a solenoid that
opens a damper door that supplies air to the wood/coal
fire. When terminal 2 is energized, it closes this
damper door and energizes the T&T terminals, which in
turn energizes the burner.
NOTE
:
Refer to the electrical drawings in the
Exploded View/Parts List Section for details.
FIG. 23
FIG. 24
Questions? Visit www.yukon-eagle.com or call 1-800-358-0060
To T & T terminals
Gas or Oil burner
To “W” on Programmable
Thermostat
To “W” on Digital Thermostat
To “C” on 24 volt Transformer
DS-103 Damper
Control
Electrical
Junction
Box
24 volt
Transformer
WOOD
GAS / OIL
27
Installation
DS-103 DAMPER
CONTROL
Summary of Contents for LWO-112
Page 9: ...9 Furnace Features Eagle I Husky...
Page 11: ...11 Furnace Features Eagle II Polar...
Page 31: ...OIL AND WOOD COAL HEATING WITH A C 31 Wiring Diagrams DS 103 DAMPER CONTROL...
Page 32: ...GAS AND WOOD COAL HEATING ONLY 32 Wiring Diagrams DS 103 DAMPER CONTROL...
Page 33: ...GAS AND WOOD COAL HEATING WITH A C 33 Wiring Diagrams DS 103 DAMPER CONTROL...
Page 56: ...EAGLE I HUSKY MODELS LWO 112 LWG 112 56 Exploded Views Parts Lists...
Page 58: ...EAGLE II POLAR MODELS LWO 168 LWG 168 58 Exploded Views Parts Lists...
Page 62: ...WAYNE MODEL P250AF DIN GAS BURNER 62 Exploded Views Parts Lists...