INSTALLATION
Install barometric draft regulator
using a 24 or 26 gauge 8” X 8” X 8”
black sheet metal Tee.
DO NOT ATTACH DRAFT
REGULATOR TO TOP OR
BOTTOM OF FLUE PIPE,
NOR IN ROOM SEPARATED
FROM APPLIANCE.
BEST LOCATION IS AS
CLOSE TO APPLIANCE AS
POSSIBLE.
IMPORTANT
:
MAKE THESE ADJUSTMENTS WHEN INSTALLING.
VERTICAL FLUE
:
Adjustment weight must be in RIGHT HAND SLOT
(Marked “V”) in bracket on gate.
The arrow on flap at bottom of gate must line up with letter “V”
on lower right part of gate. If it does not,
remove flap, turn over and snap on to gate again.
Flap can be removed by inserting small screw driver at the
back side of the gate between the gate and the flap, then pull-
ing downward on flap.
HORIZONTAL FLUE
:
Adjustment weight must be in LEFT HAND SLOT
(Marked “H”) in bracket on gate.
The arrow on flap at bottom of gate must line up with letter “H”
on lower left part of gate. If it does not, remove flap, turn over
and snap on to gate again.
IMPORTANT
A MANOMETER MUST BE USED TO
ACCURATELY ADJUST FLUE DRAFT
35
Weight on Right Side
of Bracket (“V”)
Weight on Left Side
of Bracket (“H”)
Use Spirit Level to make sure that the control does not lean
forward or backward but instead is plumb in both directions,
regardless of whether the flue is horizontal, vertical or sloping.
Installation
DRAFT REGULATOR
Summary of Contents for LWO-112
Page 9: ...9 Furnace Features Eagle I Husky...
Page 11: ...11 Furnace Features Eagle II Polar...
Page 31: ...OIL AND WOOD COAL HEATING WITH A C 31 Wiring Diagrams DS 103 DAMPER CONTROL...
Page 32: ...GAS AND WOOD COAL HEATING ONLY 32 Wiring Diagrams DS 103 DAMPER CONTROL...
Page 33: ...GAS AND WOOD COAL HEATING WITH A C 33 Wiring Diagrams DS 103 DAMPER CONTROL...
Page 56: ...EAGLE I HUSKY MODELS LWO 112 LWG 112 56 Exploded Views Parts Lists...
Page 58: ...EAGLE II POLAR MODELS LWO 168 LWG 168 58 Exploded Views Parts Lists...
Page 62: ...WAYNE MODEL P250AF DIN GAS BURNER 62 Exploded Views Parts Lists...