5.2 Soak mode(PAF : B=1)
Suitable for the process which does not need to establish the temperature slope, can simplify the programming and
more effective. Each step also can set parameter “SPr” to define temperature raise slope, if “SPr=0” raising speed will
set to maximum. Because cannot know the actual time which spend on temperature raising, user can enable “rdy”
function to ensure the correct soak time.
Time setting
Set “t-xx” = 0.1
~
3200 (min)
Set the time of xx StEP. (Time units can be change to Hour by parameter “PAF”.)
Set “t-xx” = 0.0
The program hold on StEP xx, program will hold running and hold counting time.
Set “t-xx” = -121.0
The program stops, and switches to stop status.
Set “t-xx” = -0.1
~
-122.0
Negative value of this range represents a jump operation which will jump to step xx and event output. Range -1~-120
is for step jumping application. The step jumping cannot greater than “Pno”(No. of Program step).
Decimal point use for control the event output from AL1 and AL2. (Modular), Note, if parameter AOP was assigned
alarm action will trigger from AL1 and AL2, the event output also will cause alarm from AL1 and AL2.