background image

24 

Boss X-series  

Instructions for use 

25

youngmangroup.com 

 

6.1 MachIne laBellIng 

6.1 MachIne laBellIng 

See below for the correct location of  the BoSS 
X-Series machine labels and machine plate

On all four forklift and transit strap points

  

Located on the end of the chassis as 

indicated on the page opposite.

10

  BoSS X3X iS deSigned 

for indoor uSe only. 

it muSt not Be uSed 

outdoorS

  maXimum Wind Speed

:

 

0 metreS/Second

  maXimum manual force

:

 

200 neWtonS

  maXimum alloWaBle 

chaSSiS inclination

:

 

1.25 degreeS

  enSure Both SWivel 

caStor BrakeS 

are locked Before 

elevating the 

platform

 Safe Working load: 240kg 

1 perSon 

(80kg)

+

toolS & 

materialS 

(160kg)

  do not attempt to 

move the platform 

When elevated

  do not attempt to 

overreach.

  paying particular 

attention to the 

Safety ruleS read 

and underStand the 

inStructionS for 

uSe, located in the 

tuBe BeloW, Before 

operating thiS 

machine

  on deScent there iS an 

automated 

intermediate Stop at 

1.87 metreS. check 

around the platform 

and if Safe to continue 

preSS the ‘doWn’ 

Button

01

Battery Charge 

level indiCator

:

led displays 

Battery Charge 

level

Charger 

indiCator Lights

aC

Power 

suPPLy

Charge 

to 80% of 

battery 

CaPaCity

Charge 

remaining 

20% of 

battery 

CaPaCity

Charging 

indiCator

Charging Cables 

tray

To lower The plaTform wiThouT 

power in an emergency

1

 

Turn The valve on The Pressure 

loss valve on The hydraulic ram 

anTiclockwise unTil iT will noT 

Turn any furTher

2

 

Turn The valve adjacenT To This 

label anTiclockwise unTil The 

PlaTform begins To descend.

To sToP The PlaTform aT any 

Time, Turn The valve clockwise.

Prior To The resToraTion of Power Turn boTh 

valves clockwise unTil fully TighT and Then use 

The handseT conTroler in accordance wiTh The 

insTrucTions for use.

Do noT uSe a preSSure waSher on ThiS SiDe 

of The BaSe uniT unleSS BoTh ruBBer plugS 

are in poSiTion

Fork LiFting 

Point

Pass transit 

straPs 

through here

MaxiMuM 

WheeL 

Load 

450kg

InstructIons 

for use 

EnsurE both maintEnancE props arE in position bEforE 

undErtaking maintEnancE on thE raisEd platform.

 

    Pressure loss 

valve

In the event of a loss of power or 

hydraulIc pressure turn the valve 

antIclockwIse untIl It wIll not turn any 

further.

prIor to the restoratIon of power and 

or hydraulIc pressure close thIs valve 

by turnIng clockwIse.

 

Attention 

Press the emergency stoP button 

on the hAndset And remove the 

key Prior to chArging. 

Power suPPly

:

 110 or 240 volts.

select the APProPriAte cAble 

from the trAy under the PlAtform 

Access steP And Plug in below. 

!

eMergency 

stoP

04

05

06

07

08

09

10

11

12

02

01

04

05

11 12 13 14

13

06

09

07/08

X X X

14

02

03

MAXIMUM SAFE WORKING LOAD 240KG – 

ONE PERSON PLUS TOOLS AND MATERIALS

03

Summary of Contents for BOSS X Series

Page 1: ...Picture of machine being used in situ at full height The ultimate range of push around micro powered access platforms Instructions for use Edition January 2010 EN 280 IP24...

Page 2: ...Page 1 1 Introduction 1 1 2 Characteristics and description 2 1 3 Intended use 3 1 4 Selection and minimum attributes of operators 4 1 5 Modifications 5 1 6 Terminology 6 Section 2 Specification 2 1...

Page 3: ...ent Pull out storage drawer for charging cables and guardrail tools Wide forklift entry hoisting and transit strap points Smooth roll castors with non marking tyres Maintenance Manual EC Declaration o...

Page 4: ...y and manoeuvre the machine as required to correctly position and carry out the tasks in a correct and proper manner k be able to identify and avoid foreseeable hazards and recognise unsafe practices...

Page 5: ...8 Step up to platform 9 Fixed castors with auto braking applied as the platform is raised 10 Swivel castors with click on brakes 11 Emergency lowering release valve 12 Guardrails 13 Work Platform 14...

Page 6: ...4m Platform width 0 57m Platform length 1 25m 1 05m 1 05m Platform guardrail height 1 1m Toeboard height 0 15m Overall width 0 76m 0 7m 0 7m Stowed height 1 8m 1 8m 1 7m Stowed length 1 41m 1 21m 1 2...

Page 7: ...ctrical cables Every worksite should be subject to a risk assessment and where vehicle movements are likely to occur close to the BoSS X Series machine measures should be taken to segregate the machin...

Page 8: ...erreach ALWAYS check that there are no obstructions or persons that may be struck by the platform before and during the raising and lowering of the platform ALWAYS carry tools and materials within the...

Page 9: ...t Emergancy stop function activated on the base unit Emergency lowering of platform see page 19 Raise and lower functions including descent delay the raise and lower functions can be tested by removin...

Page 10: ...in use 4 4 Battery Isolation Switch The BoSS X Series machine is provided with a key operated switch which is used to isolate the battery and therefore the electrical system preventing unauthorised us...

Page 11: ...to release the button as shown below There is also an emergency stop button on the base unit Push in to activate and twist clockwise to release In the unlikely event of a power failure of the BoSS X...

Page 12: ...ry is fully charged all four lights will illuminate after approximately 10 hours The BoSS X Series machine should be stored inside in a secure clean and dry environment the emergency stop on the hands...

Page 13: ...machine must be adequately rated The BoSS X Series machine may be lifted by a crane or Hiab by threading adequately rated lifting straps through the forklift access points WARNING A full risk assessme...

Page 14: ...ing Cables tray To lower The plaTform wiThouT power in an emergency 1 Turn The valve on The Pressure loss valve on The hydraulic ram anTiclockwise unTil iT will noT Turn any furTher 2 Turn The valve a...

Page 15: ...ation By 6 3 Repairs record Date Repairs undertaken Location By 6 4 Examination tests record Date Examinations tests undertaken Location By Safe to use Y N Please photocopy these pages for your own us...

Page 16: ...orm scissors and chassis eg damage cracks corrosion abrasions welds connections Visual inspection of the castellated scissor nuts and the split pin retainers Obscured dirty or damaged instruction labe...

Page 17: ...ints to allow access to restricted spaces such as the void above suspended ceilings Bumpers The BoSS X Series Bumpers have been specially designed to fit easily into the machines fork lifting points a...

Page 18: ...32 BoSS X Series Instructions for Use 33 youngmangroup com NOTES Notes...

Page 19: ...products or any other of our other products and services please contact Youngman Group Ltd The Causeway Maldon Essex CM9 4LJ United Kingdom t 44 0 1621 745900 f 44 0 1621 859845 e sales youngmangroup...

Reviews: