![background image](http://html1.mh-extra.com/html/york/yhau-ce/yhau-ce_installation-operation-and-maintenance_3511378032.webp)
JOHNSON CONTROLS
32
FORM 155.35-ICOM2.EN.CE/GB (1018)
DATE: 10/30/2018
SECTION 3 – HANDLING, STORAGE, INSTALLATION AND REASSEMBLY
Do not leave any flammable substance
or easily combustible object near the ma-
chine, flue, smokestack or oil tank.
LD22964
Sole Plate
Plate
Rubber Pad
Base
Rubber Vibration
Isolator
Nut
Washer
Foundation Bolt
Foundation Bolt
Rubber Vibration
Isolator
Sole Plate
Filling with
motrar
Nut
Washer
VIBRATION AND ISOLATION DETAILS
Before installing the unit, fit rubber vibration isolators
to the unit base as shown in
be-
low. Use liners to adjust the levelness of the unit. For
unit dimensions, see
FIGURE 7 -
VIBRATION AND ISOLATION DETAILS