JOHNSON CONTROLS
FORM 201.23-EG1 (1013)
49
Contact your nearest Johnson Controls Sales Office for weight data.
REFRIGERANT R-134A
STANDARD EFFICIENCY
MODEL NUMBER (YCIV____ S/P)
GENERAL UNIT DATA
60Hz
0287
0307
0357
0397
0457
NUMBER OF INDEPENDENT REFRIGERANT CIRCUITS
3
3
3
3
4
REFRIGERANT CHARGE, R-134A, CKT.-1/CKT.-2, LBS
185/170/170
185/185/170
185/185/230
230/230/230
310/310/300/300
OIL CHARGE, CKT.-1/CKT.-2, GAL.
5/4/4
5/4/4
5/5/5
5/5/5
5/5/5/5
GLYCOL CHARGE (43% CONCENTRATION), GAL
5.4
5.5
6.0
6.3
4.3
COMPRESSORS, SEMI-HERMETIC SCREW QTY PER CHILLER
3
3
3
3
4
CONDENSERS, HIGH EFFICIENCY FIN/TUBE WITH INTEGRAL SUBCOOLER
TOTAL CHILLER COIL FACE AREA, FT
2
381
411
469
528
528
NUMBER OF ROWS
3
3
3
3
4
FINS PER INCH
17
17
17
17
17
CONDENSER FANS
NUMBER, CKT.-1/CKT.-2
5/4/4
5/4/4
5/5/6
6/6/6
6/6/3/3
LOW NOISE FANS
FAN MOTOR, HP/KWI
2/1.8
2/1.8
2/1.8
2/1.8
2/1.8
TOTAL CHILLER AIRFLOW, CFM
169000
182000
208000
234000
234000
ULTRA QUIET FANS
FAN MOTOR, HP/KWI
2/1.50
2/1.50
2/1.50
2/1.50
2/1.5
TOTAL CHILLER AIRFLOW, CFM
169000
182000
208000
234000
234000
DUAL SPEED FANS - NORMAL SPEED
FAN MOTOR, HP
2
2
2
2
2
TOTAL CHILLER, CFM
143000
143000
165000
165000
165000
DUAL SPEED FANS - LOWER SPEED
FAN MOTOR, HP
2
2
2
2
2
TOTAL CHILLER, CFM
109200
109200
126000
126000
126000
HIGH STATIC FANS
FAN MOTOR, HP
5
5
5
5
5
TOTAL CHILLER, CFM
169000
182000
208000
234000
234000
EVAPORATOR, DIRECT EXPANSION
WATER VOLUME, GALS.
202.0
236.0
236.0
236.0
318
MAXIMUM WATER SIDE PRESSURE, PSIG
150
150
150
150
150
MAXIMUM REFRIGERANT SIDE PRESSURE, PSIG
235
235
235
235
235
MINIMUM CHILLED WATER FLOW RATE, GPM
250
300
300
300
400
MAXIMUM CHILLED WATER FLOW RATE, GPM
1200
1200
1200
1200
1400
WATER CONNECTIONS, INCHES
10
10
10
10
10
Summary of Contents for YCIV0157E/V
Page 57: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 57...
Page 59: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 59...
Page 61: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 61...
Page 63: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 63...
Page 65: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 65...
Page 67: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 67...
Page 69: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 69...
Page 71: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 71...
Page 73: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 73...
Page 75: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 75...
Page 77: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 77...
Page 89: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 89 INTENTIONALLY LEFT BLANK...
Page 102: ...JOHNSON CONTROLS 102 FORM 201 23 EG1 1013 Typical Control Wiring Two Compressor...
Page 104: ...JOHNSON CONTROLS 104 FORM 201 23 EG1 1013 Typical Control Wiring Three Compressor...
Page 106: ...JOHNSON CONTROLS 106 FORM 201 23 EG1 1013 Typical Control Wiring Four Compressor...
Page 107: ...JOHNSON CONTROLS FORM 201 23 EG1 1013 107...
Page 114: ...Form 201 23 EG1 1013 Supersedes 201 23 EG1 713...