45
P11
16 1
C1 C2
33
CFM
on
Heat
d
Current Transducer (CT)
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
K6
K5
CR3 -
CR4 -
F1 and F2 -
WCL -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW1 -
SW2 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Water Coil Limit Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 5 position AXB
TEST MODE ABC Board
DIP package 8 position ABC Board
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
GG
TT
1
3
2
P
1
3
2
P
L1
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4 -
Aux heat stage relays
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
CS -
Compressor Solenoid
Breaker
Current Transducer (CT)
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
K6
K5
CR3 -
CR4 -
F1 and F2 -
WCL -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW1 -
SW2 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Water Coil Limit Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 5 position AXB
TEST MODE ABC Board
DIP package 8 position ABC Board
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
1
3
2
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4 -
Aux heat stage relays
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
CS -
Compressor Solenoid
Breaker
Notes
Notes
3 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
7 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
5 – Brown blower power wire routed through Current Transducer two times.
6 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
4 – Low voltage wiring CLASS 2.
8 - Wiring harness supplied with valve.
Notes
3 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
7 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
5 – Brown blower power wire routed through Current Transducer two times.
6 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
4 – Low voltage wiring CLASS 2.
8 - Wiring harness supplied with valve.
2
3
P9
5
4
1
L2
L1
L2
L1
Green
P11
2 3 4 5
1
Violet
Blue
Brown
Orange
HE1
TS1
TS1
HE1
TS1
HE3
TS3
TS3
HE3
TS3
HE2
TS2
TS2
HE2
TS2
HE4
TS4
TS4
HE4
TS4
Connects to variable
speed ECM motor only
60 AMP
BRK1
60 AMP
BRK2
GG
GG
K1
K2
K3
K4
NO
NO
NO
NO
EA Series
PCB
P1
4
1 2 3
C
G
G
G
G
K5
NO
K6
NO
K7
NO
K8
NO
Gray
Yellow
Gray
Yellow
Black
Pink
Black
Pink
Pink
Pink
Gray
Black
Yellow
Gray
Black
Yellow
4
1 2 3
C
P2
COM
COM
COM
COM
COM
COM
COM
COM
Aux heat staging
FB1
FB2
FB3
FB4
P3 on Aurora ABC Board
P3
EH2
C EH1 C
CO
P3
EH2
C EH1 C
CO
Light emitting diode - Green
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Thermal Limit Switch
Field wire lug
Ground
HE -
PB -
Heater element
Power block
Legend
N.O., N.C.
G
L1
Breaker
1 2 3
P
TS
Electric Heat Relay
K*
Fused Backup
FB
K*
Fused Backup
FB
Light emitting diode - Green
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Thermal Limit Switch
Field wire lug
Ground
HE -
PB -
Heater element
Power block
Legend
N.O., N.C.
G
L1
Breaker
1 2 3
P
TS
Electric Heat Relay
K*
Fused Backup
FB
2 - Use manufacturer’s part number 19P592-01 (jumper
bar assembly) when single source power is required.
1 - Use copper conductors.
3 – Jumpers wires are Factory Installed, and are
required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
2 - Use manufacturer’s part number 19P592-01 (jumper
bar assembly) when single source power is required.
1 - Use copper conductors.
3 – Jumpers wires are Factory Installed, and are
required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
NOTE 3
With optional EA Series 20kW Auxiliary Electric Heat Shown
2
3
P9
5
4
1
L2
L1
L2
L1
Green
P11
2 3 4 5
1
Violet
Blue
Brown
Orange
HE1
TS1
HE3
TS3
HE2
TS2
HE4
TS4
Connects to variable
speed ECM motor only
60 AMP
BRK1
60 AMP
BRK2
G
G
K1
K2
K3
K4
NO
NO
NO
NO
EA Series
PCB
P1
4
1 2 3
C
G
G
G
G
K5
NO
K6
NO
K7
NO
K8
NO
Gray
Yellow
Gray
Yellow
Black
Pink
Black
Pink
Pink
Pink
Gray
Black
Yellow
Gray
Black
Yellow
4
1 2 3
C
P2
COM
COM
COM
COM
COM
COM
COM
COM
Aux heat staging
FB1
FB2
FB3
FB4
P3 on Aurora ABC Board
P3
EH2
C EH1 C
CO
Light emitting diode - Green
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Thermal Limit Switch
Field wire lug
Ground
HE -
PB -
Heater element
Power block
Legend
N.O., N.C.
G
L1
Breaker
1 2 3
P
TS
Electric Heat Relay
K*
Fused Backup
FB
2 - Use manufacturer’s part number 19P592-01 (jumper
bar assembly) when single source power is required.
1 - Use copper conductors.
3 – Jumpers wires are Factory Installed, and are
required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
NOTE 3
With optional EA Series 20kW Auxiliary Electric Heat Shown
9 - On units with the NIDEC ECM motor the P13 harness connects to the
jumper harness on the motor.
Wiring Schematics cont.
Aurora Advanced with ECM and IntelliStart cont.
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
Summary of Contents for YAFT026
Page 2: ......
Page 75: ...75 Notes AFFINITY AFFINITY ADVANCED SINGLE DUAL CAPACITY SERIES INSTALLATION MANUAL...
Page 77: ...77...