53
Current Transducer (CT)
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
K5 -
K6 -
CR3 -
CR4 -
F1 and F2 -
WCL -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW1 -
SW2 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Water Coil Limit Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 5 position AXB
TEST MODE ABC Board
DIP package 8 position ABC Board
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
1
3
2
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4 -
Aux heat stage relays
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
CS -
Compressor Solenoid
Breaker
Aurora LED Flash Codes
Status LED (LED3, Green)
Status LED (LED1, Green)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Random Start Delay (Alternating Colors)
Fast Flash
Fast Flash
Fast Flash
1 second on and 1 second off
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Slow Flash
Fast Flash
Flash Code
Normal Mode
Control is Non-Functional
Test Mode
Lockout Active
Dehumidification Mode
Future Use
Future Use
Load Shed
ESD
OFF
ON
Slow Flash
Fast Flash
Flash Code 2
Flash Code 3
Flash Code 6
Flash Code 4
Flash Code 5
Future Use
Flash Code 7
Configuration LED (LED2, Yellow)
No Software Overide
OFF
DIP Switch Overide
Slow Flash
Fault LED (LED1, Red)
Normal Mode
Input Fault Lockout
High Pressure Lockout
Low Pressure Lockout
Future Use
Freeze Detection – FP1
Reserved
Condensate Overflow Lockout
Over/Under Voltage Shutdown
Future Use
Future Use
FP1 Sensor Error
Flash Code 1
OFF
Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5
Flash Code 8
Flash Code 6
Flash Code 7
Flash Code 9
Flash Code 10
Flash Code 11
Communicating Thermostat
Dual Fuel Wiring Diagram
Using Field Installed Relay
24VDC
R from Foss il
Fue l Furnac e
To Foss il Fuel
Furnac e W input
EH1
C
ABC
Board
Note 8: Fiel d i ns ta lled SPST dua l fue l rel ay
(Re quired for dual fuel i ns ta llation)
With optional EA Series 10kW Auxiliary Electric Heat Shown
2 – When Auxiliary Heat is installed the BLK/WHT
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
1 - Use copper or aluminum conductors.
3 – Jumpers wires are Factory Installed, and are
Required for auxiliary heat operation.
4 – Low voltage wiring CLASS 2.
Violet
Blue
2
3
Black
Gray
Black
Gray
Green
P9
K1
K2
NO
NO
Brown
Orange
5
4
EA Series PCB
P2
1
L2
L1
G
208-230/60/1
Green
P11
2 3 4 5
1
C 1 2 3 4
P3 on Aurora ABC Board
P3
EH2
C EH1 C
CO
Condensate
Brown
Orange
P1
4
1 2 3
C
G
G
To PB2
TB
K4
NO
G
K3
NO
G
Gray
Gray
Black
Black
Black
Gray
NOTE 3
Connects to variable
speed ECM motor only
HE1
TS1
HE2
TS2
Light emitting diode - Green
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Thermal Limit Switch
Field wire lug
Ground
HE -
PB -
Heater element
Power block
Legend
N.O., N.C.
G
L1
Breaker
1 2 3
P
TS
Electric Heat Relay
K*
Fused Backup
FB
FB1
FB2
Wiring Schematics cont.
Aurora Base with PSC cont.
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
Summary of Contents for YAFT026
Page 2: ......
Page 75: ...75 Notes AFFINITY AFFINITY ADVANCED SINGLE DUAL CAPACITY SERIES INSTALLATION MANUAL...
Page 77: ...77...