Supply static 

after

 indoor coil (in w.c.")

Return Static (in w.c.") 

before 

filter

Total External Static Pressure

Low

1

2

Medium Low

Medium 

Medium High 

High

5

A

B

D

C

A

B

C

D

Air Side: System Total External Static Pressure

Supply static 

before

 indoor coil (in w.c.")

Return Static (in w.c.") 

after 

filter (furnace side)

  
  

 Cooling  

&  

Heat Pump 

 Indoor 

Blower Set-Up

COOL

ADJUST

ECM

X-13

PSC

A

B

C

D

DELAY

  

Supplementary  

Heating 

 Indoor 

Blower Set-Up

ECM

X-13

PSC

A

1

5

High

2

Low

Medium  

Low

Medium 

Medium  

High 

D

B

C

Outside Air: Dry Bulb  

Temperature Drop

Supply Air: Dry Bulb

Return Air: Dry Bulb

Wet Bulb

Temperature Rise

Return Air: Dry Bulb

Supply Air: Dry Bulb

Wet Bulb

Version Number

Defrost Control Board

Part Number

Demand Defrost

YorkGuard VI

Time and Temperature

Maximum Rated ESP (in w.c.")

Low Temp Cut Out 

Balance Point 

Defrost Curve  

Y2 Lock 

FFUEL 

Switch Point 

Hot Heat Pump

Fill in the information ie.. "ON", "OFF" or the appropriate "Value" for the fields that apply to the defrost control board installed

Run Time: Time and Temperature board only 30, 60 or 90 minutes

Bonnet Sensor Present

HEAT

Refrigerant Charge and Metering Device

TXV

Fixed Orifice

R-22

R-410A

Oz.

# 45s

# Elbows

TXV #

Orifice Size

Liquid Line Temp

Subcooling

Superheat

High Side Pressure

Low Side Pressure

Suction Line Temp

Additional Lineset Length

Adder per foot  -  lbs.

Total Added - lbs.

Oz.

Cycle Test

Operate the unit through several heating cycles from the thermostat, noting and correcting any problems

Operate the unit through continuous fan cycles from the thermostat, noting and correcting any problems

Operate the unit through a cooling cycles, noting and correcting any problems

Operate the unit through an emergency heating cycles, noting and correcting any problems

Installation debris disposed of and indoor and outdoor areas cleaned up?

Clean Up

 

Continued on next Page

Summary of Contents for THJF60

Page 1: ...al line lengths Refer to Appli cation Data covering General Piping Recommendations and Refriger ant Line Length Part Number 247077 SECTION II SAFETY This is a safety alert symbol When you see this sym...

Page 2: ...er of hot air into the outdoor unit Provide adequate structural support ADD ON REPLACEMENT RETROFIT When this unit is being used as a replacement for an R 22 unit it is required that the outdoor unit...

Page 3: ...eet The charge given is applicable for total tubing lengths up to 15 feet See Application Data Part Number 247077 for installing tubing of longer lengths and elevation differences PRECAUTIONS DURING L...

Page 4: ...er grommet from the vapor connection at the indoor coil Braze the vapor line to the evaporator vapor connection After the connection has cooled place the rubber grommet back into the mounting position...

Page 5: ...al 1 3 turn to seal 8 Install the TXV bulb to the suction line near the equalizer line using the bulb clamp s furnished with the TXV assembly kit Ensure the bulb is making maximum contact a Install th...

Page 6: ...coil adjustment if any from Tabular Data Sheet 3 Calculate the additional charge for refrigerant piping using the Tabu lar Data Sheet if line length is greater than 15 feet 4 6 m 4 Total system charge...

Page 7: ...itches and over current protection must be supplied by the installer Wire size should be sized per NEC requirements The complete connection diagram and schematic wiring label is located on the inside...

Page 8: ...he recommended air flow settings for each size condensing unit Set the cooling speed per the instructions for the air handler or furnace by selecting the correct COOL and ADJUST or ADJ taps Verify the...

Page 9: ...4 Volt Hot W3 Third Stage Heat COM 24 Volt Common R 24 Volt Hot W1 First Stage Aux Heat W2 Second Stage Aux Heat Y1 Single Stage Compressor Y Y2 Second or Full Stage Compressor O Reversing Valve Energ...

Page 10: ...uxiliary Heat COM 24 Volt Common R 24 Volt Hot W1 First Stage Aux Heat W2 Second Stage Aux Heat Y1 Single Stage Compressor Y Y2 Second or Full Stage Compressor O Reversing Valve Energized in Cool X L...

Page 11: ...energized only when the unit is not running If the main switch is disconnected for long peri ods of shut down do not attempt to start the unit until 8 hours after the switch has been connected This wi...

Page 12: ...GRN GREEN GRY GREY ORG ORANGE PUR PURPLE RED RED WHT WHITE YEL YELLOW Y B YEL BLK LEGEND AS AMBIENT SENSOR CAP CAPACITOR COMP COMPRESSOR CC CONTACTOR COIL CCH CRANKCASE HEATER DS DISCHARGE SENSOR HPS...

Page 13: ...plicable Electrical Line Voltage Outdoor Unit Model Outdoor Unit Serial Filter Thermostat Accessories Filter Location s Connections Per Installation Instructions and Local Codes Gas piping is connecte...

Page 14: ...p Cut Out Balance Point Defrost Curve Y2 Lock FFUEL Switch Point Hot Heat Pump Fill in the information ie ON OFF or the appropriate Value for the fields that apply to the defrost control board install...

Page 15: ...plain operation of system to equipment owner Explain the importance of regular filter replacement and equipment maintenance Owner Education Provide owner with the owner s manual Explain thermostat use...

Page 16: ...change without notice Published in U S A 835959 UIM D 0814 Copyright 2014 by Johnson Controls Inc All rights reserved Supersedes 835959 UIM C 0614 York International Corp 5005 York Drive Norman OK 73...

Reviews: