background image

835959-UIM-D-0814

12

Johnson Controls Unitary Products

SECTION XI: WIRING DIAGRAM

 FIGURE 10:  

Wiring Diagram - Single Phase - 14.5 SEER - 5 Ton

449672-UWD-C-0213

C

M1

M2

M

HPS

HPS

C

Y1

Y2

O

W

X/L

R

BSG

BS

Y2 OUT

W2 OUT

W1 OUT

RV

RVG

LPS

LPS

L1

ODF

CCH

LLG

LL

AMB

AMBG

DIS

DISG

BLK

YEL

ORG

WHT

PUR

RED

YEL/BLK

YEL/BLK

BLU

GRY

BRN

YEL

BRN/PNK

BRN/PNK

BLK/PNK

BLK/PNK

BLK

BLK

BLU

BLU

WHT

WHT

HPS

LS

BLK

GRY

SEE UNIT INSTALLATION INSTRUCTIONS

FOR LOW VOLTAGE TERMINATIONS

DEFROST CONTROL

BLU/YEL

ORG

LPS

RV

AS

S

C

R

FAN MOTOR

GND

6

3

5

4

2

1

GRN

BRN

RED

BLK

RED

BRN/WHT

CAP

H

C

F

BRN

BLK

RED

L1

L2

T1

T2

USE COPPER

CONDUCTORS

ONLY

208-230 VAC 60 Hz

1 PHASE SUPPLY

CC

COMP

PLUG

CONTACTOR

1

2

4

3

230V

24V

RED

FIELD WIRING, LINE VOLTAGE

OPTIONAL WIRING

LOW VOLTAGE FACTORY WIRING

HIGH VOLTAGE FACTORY WIRING

COLOR CODE
 
BLK - BLACK
BLK/PNK -
BLACK/PINK -
BLU - BLUE
BRN - BROWN
BLU/YEL -
BLUE/YELLOW
BRN/PNK -
BROWN/PINK
BRN/WHT - 
BROWN/WHITE
GRN - GREEN
GRY - GREY
ORG - ORANGE
PUR - PURPLE
RED - RED
WHT - WHITE
YEL - YELLOW
Y/B - YEL/BLK

LEGEND
 
AS   - AMBIENT SENSOR
CAP  - CAPACITOR
COMP - COMPRESSOR
CC   - CONTACTOR COIL
CCH  - CRANKCASE HEATER
DS   - DISCHARGE SENSOR
HPS  - HIGH PRESS SWITCH
IR   - ISOLATION RELAY
LS   - LIQUID SENSOR
LPS  - LOW PRESS SWITCH
OFM  - OUTDOOR FAN MOTOR
RV   - REVERSING VALVE
SC   - START CAPACITOR
SOL  - SOLENOID
SR   - START RELAY
XFRM - TRANSFORMER

BLK

BLK

BLU

BRN

IR

XFMR

R

C

S

BLU

BLU

2 STAGE COMP

SOL COIL

 
TURN OFF ELECTRICAL POWER BEFORE
SERVICING TOPREVENT POSSIBLE DAMAGE
TO THE EQUIPMENT AND POSSIBLE
PERSONAL INJURY.
 
 
 
TO PREVENT ELECTRICAL SHOCK OPEN
REMOTE DISCONNECT SO ELECTRICAL
SUPPLY TO AIR CONDITIONER IS SHUT OFF.
 
     COMPONENTS SHOWN IN DASHED
     LINES ARE OPTIONAL.
 
     DUAL CAPACITOR SHOWN. SEPARATE
     CAPACITORS MAY BE USED ON ACTUAL
     UNIT.
 
     WIRING MUST CONFORM TO
     NATIONAL AND LOCAL CODES.
 
     IF ANY OF THE ORIGINAL WIRE
     SUPPLIED WITH THIS UNIT MUST BE
     REPLACED, IT MUST BE REPLACED
     WITH TYPE 105°C. THERMOPLASTIC
     OR ITS EQUIVALENT.
 
     WHERE POWER SUPPLY HAS ONE (1) 230
     VOLT CONDUCTOR AND ONE (1) 
     NEUTRAL CONDUCTOR. CONNECT L2 OF
     CONTACTOR TO NEUTRAL.
 
     
 

DANGER - SHOCK HAZARD

CAUTION

1

2

3

4

5

RED

Summary of Contents for THJF60

Page 1: ...al line lengths Refer to Appli cation Data covering General Piping Recommendations and Refriger ant Line Length Part Number 247077 SECTION II SAFETY This is a safety alert symbol When you see this sym...

Page 2: ...er of hot air into the outdoor unit Provide adequate structural support ADD ON REPLACEMENT RETROFIT When this unit is being used as a replacement for an R 22 unit it is required that the outdoor unit...

Page 3: ...eet The charge given is applicable for total tubing lengths up to 15 feet See Application Data Part Number 247077 for installing tubing of longer lengths and elevation differences PRECAUTIONS DURING L...

Page 4: ...er grommet from the vapor connection at the indoor coil Braze the vapor line to the evaporator vapor connection After the connection has cooled place the rubber grommet back into the mounting position...

Page 5: ...al 1 3 turn to seal 8 Install the TXV bulb to the suction line near the equalizer line using the bulb clamp s furnished with the TXV assembly kit Ensure the bulb is making maximum contact a Install th...

Page 6: ...coil adjustment if any from Tabular Data Sheet 3 Calculate the additional charge for refrigerant piping using the Tabu lar Data Sheet if line length is greater than 15 feet 4 6 m 4 Total system charge...

Page 7: ...itches and over current protection must be supplied by the installer Wire size should be sized per NEC requirements The complete connection diagram and schematic wiring label is located on the inside...

Page 8: ...he recommended air flow settings for each size condensing unit Set the cooling speed per the instructions for the air handler or furnace by selecting the correct COOL and ADJUST or ADJ taps Verify the...

Page 9: ...4 Volt Hot W3 Third Stage Heat COM 24 Volt Common R 24 Volt Hot W1 First Stage Aux Heat W2 Second Stage Aux Heat Y1 Single Stage Compressor Y Y2 Second or Full Stage Compressor O Reversing Valve Energ...

Page 10: ...uxiliary Heat COM 24 Volt Common R 24 Volt Hot W1 First Stage Aux Heat W2 Second Stage Aux Heat Y1 Single Stage Compressor Y Y2 Second or Full Stage Compressor O Reversing Valve Energized in Cool X L...

Page 11: ...energized only when the unit is not running If the main switch is disconnected for long peri ods of shut down do not attempt to start the unit until 8 hours after the switch has been connected This wi...

Page 12: ...GRN GREEN GRY GREY ORG ORANGE PUR PURPLE RED RED WHT WHITE YEL YELLOW Y B YEL BLK LEGEND AS AMBIENT SENSOR CAP CAPACITOR COMP COMPRESSOR CC CONTACTOR COIL CCH CRANKCASE HEATER DS DISCHARGE SENSOR HPS...

Page 13: ...plicable Electrical Line Voltage Outdoor Unit Model Outdoor Unit Serial Filter Thermostat Accessories Filter Location s Connections Per Installation Instructions and Local Codes Gas piping is connecte...

Page 14: ...p Cut Out Balance Point Defrost Curve Y2 Lock FFUEL Switch Point Hot Heat Pump Fill in the information ie ON OFF or the appropriate Value for the fields that apply to the defrost control board install...

Page 15: ...plain operation of system to equipment owner Explain the importance of regular filter replacement and equipment maintenance Owner Education Provide owner with the owner s manual Explain thermostat use...

Page 16: ...change without notice Published in U S A 835959 UIM D 0814 Copyright 2014 by Johnson Controls Inc All rights reserved Supersedes 835959 UIM C 0614 York International Corp 5005 York Drive Norman OK 73...

Reviews: