background image

397763-YTG-B-0508

Johnson Controls Unitary Products

5

— = Not applicable.

13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED

THGD18S41S1

AV24 17  –

550 

17.0 

13.0 

14.00 

12.00 

THGD24S41S1

AV24 17  –

750 

23.0 

17.2 

14.00 

12.00 

AV36 21  –

750 

23.0 

18.0 

14.00 

12.00 

THGD30S41S1

AV36 21  –

1000 

29.0 

24.4 

14.00 

12.00 

THGD36S41S1

AV36 21  –

1250 

35.0 

28.0 

13.50 

11.50 

THGD42S41S1

AV/SV48 24 

1400 

41.5 

32.0 

14.00 

12.00 

THGD48S41S1

AV/SV48 24 

1600 

47.5 

36.2 

14.00 

11.80 

AV/SV60 24 

1650 

47.5 

36.6 

14.00 

11.80 

F4FV060 24 

1600 

47.5 

36.2 

14.00 

11.80 

13 SEER HP WITH AHP / SHP / F*FP

THGD18S41S1

AHP18 17 

600 

17.0 

12.7 

13.00 

11.00 

F4FP024 17 

600 

17.0 

12.6 

13.00 

11.00 

THGD24S41S1

AHP30 17 

800 

23.0 

17.2 

13.00 

11.00 

F4FP030 17 

800 

23.0 

16.9 

13.00 

11.00 

THGD30S41S1

AHP36 21 

1000 

29.0 

23.2 

13.00 

11.00 

F4FP040 21 

1000 

29.0 

22.6 

13.00 

11.00 

THGD36S41S1

AHP36 21 

1200 

35.0 

26.8 

13.00 

11.00 

F4FP045 24 

1200 

35.0 

26.8 

13.00 

11.00 

THGD42S41S1

AHP/SHP48

21

1400

41.5

31.4

13.00

11.00

F4FP045 24 

1400 

41.0 

31.2 

13.00 

11.00 

F5FP048 24 

1450 

41.0 

32.6 

13.00 

11.00 

THGD48S41S1

AHP/SHP60 24 

1600 47.0 36.0 14.00 

11.50 

F5FP048 24 

1700 

47.5 

36.6 

14.00 

11.50 

F5FP060 24 

1700 

47.5 

36.8 

14.00 

11.50 

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

MODEL

AIR HANDLER

COIL

MODEL

1

COOLING

MODEL

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

Summary of Contents for THGD18 THRU 60

Page 1: ...ating conditions occur A liquid line filter drier further protects the compres sor DURABLE FINISH The cabinet is made of pre painted steel The pre treated galvanized steel provides a better paint to s...

Page 2: ...850 Nominal CFM 2200 2900 3100 3800 3200 3000 3000 Coil Face Area Sq Ft 15 7 18 3 21 0 23 58 23 58 23 58 23 58 Rows Deep 1 1 1 1 1 2 2 Fin Inches 22 22 22 22 22 18 18 Liquid Line Set OD Field Installe...

Page 3: ...0905 1TVM0906 Factory Charge lbs oz 6 5 8 7 9 12 9 15 9 12 13 9 13 6 Indoor Coil3 4 Additional Charge Oz FC MC PC UC18AB 0 FC MC PC UC24AB 4 0 FC MC PC30AB 0 FC MC PC32A 0 0 FC MC PC35BC 0 0 FC MC PC3...

Page 4: ...0 47 0 35 6 13 00 11 00 THGD60S41S1 MA20D 24 MC62D 1800 54 0 42 5 13 00 11 00 13 SEER HP WITH MV VARIABLE SPEED THGD18S41S1 MV12B 17 FC MC PC18B 600 17 0 12 9 14 00 12 00 MV12B 17 FC MC PC24B 600 17 0...

Page 5: ...8 13 00 11 00 THGD42S41S1 AHP SHP48 21 1400 41 5 31 4 13 00 11 00 F4FP045 24 1400 41 0 31 2 13 00 11 00 F5FP048 24 1450 41 0 32 6 13 00 11 00 THGD48S41S1 AHP SHP60 24 1600 47 0 36 0 14 00 11 50 F5FP0...

Page 6: ...0 17 21 FC MC PC43 1000 29 0 23 4 13 00 11 00 800 1200 17 HC36 1000 29 0 23 2 13 00 11 00 800 1200 21 HC42 1000 29 0 23 4 13 00 11 00 800 1200 21 24 HD48 1000 29 0 23 4 13 00 11 00 THGD36S41S1 1000 14...

Page 7: ...V 9 B12 FC MC PC30B 17 800 23 0 17 5 14 00 12 00 PV8 A12 FC MC PC32A 14 750 23 0 17 4 14 00 12 00 PV9 A12 FC MC PC32A 14 800 23 0 17 7 14 00 12 00 P C V 9 B12 FC MC PC35B 17 800 23 0 17 8 14 00 12 00...

Page 8: ...50 P C V 9 C20 HC42C 21 1200 35 0 27 2 13 50 11 50 PV8 C16 HD48C 21 1200 35 0 27 2 13 50 11 50 PV8 C20 HD48C 21 1200 35 0 27 2 13 50 11 50 P C V 9 C16 HD48C 21 1200 35 0 27 2 13 50 11 50 P C V 9 C20 H...

Page 9: ...HD60C 21 1600 47 0 35 4 14 00 11 50 P C V 9 C16 HD60C 21 1600 47 0 35 4 13 00 11 00 P C V 9 C20 HD60C 21 1600 47 0 35 4 14 00 11 50 P C V 9 D20 HD60D 24 1550 47 0 35 6 14 00 11 50 PV8 C20 MC62C 21 16...

Page 10: ...3 83 8 00 MA20D MC62D 50 5 3 38 4 38 30 6 2 28 3 93 8 00 THGD60S41S1 MA20D MC62D 56 5 3 48 4 76 35 4 2 42 4 29 8 00 13 SEER HP WITH MV VARIABLE SPEED THGD18S41S1 MV12B FC MC18B 16 7 3 52 1 39 12 7 3...

Page 11: ...SHP F FP THGD18S41S1 AHP18 17 0 3 38 1 47 8 2 2 16 1 11 7 70 F4FP24 17 0 3 34 1 49 12 5 3 04 1 21 7 70 THGD24S41S1 AHP30 23 2 3 40 2 00 12 6 2 24 1 65 7 70 F4FP030 23 2 3 40 2 00 12 6 2 24 1 65 7 70...

Page 12: ...28 0 3 34 2 46 16 4 2 28 2 11 7 70 FC MC PC35 28 0 3 34 2 46 16 4 2 30 2 09 7 70 FC MC PC37 28 2 3 40 2 43 16 6 2 32 2 10 7 70 FC MC PC43 28 2 3 40 2 43 16 6 2 32 2 10 7 70 HC36 28 2 3 34 2 47 16 4 2...

Page 13: ...1 45 8 00 PV8 A12 FC MC PC32A 22 6 3 72 1 78 12 4 2 50 1 45 8 00 PV9 A12 FC MC PC32A 23 0 3 72 1 81 12 4 2 50 1 45 8 00 P C V 9 B12 FC MC PC35B 22 8 3 72 1 80 12 4 2 50 1 45 8 00 P C V 9 C16 FC MC PC...

Page 14: ...V 9 C20 HC42C 35 0 3 54 2 90 20 8 2 44 2 50 8 00 PV8 C16 HD48C 35 0 3 40 3 02 19 4 2 26 2 52 8 00 PV8 C20 HD48C 35 0 3 40 3 02 19 4 2 28 2 49 8 00 P C V 9 C16 HD48C 35 0 3 40 3 02 19 5 2 24 2 55 8 00...

Page 15: ...V 9 D20 HC60D 50 5 3 58 4 13 30 2 2 38 3 72 8 00 PV8 C16 HD60C 49 5 2 94 4 93 30 4 2 04 4 37 8 00 PV8 C20 HD60C 49 5 3 02 4 80 30 4 2 08 4 28 8 00 P C V 9 C16 HD60C 50 0 2 98 4 92 30 6 2 06 4 35 8 00...

Page 16: ...refer to the price book or consult factory SOUND POWER RATINGS Rated in accordance with ARI 270 95 Standards TYPICAL INSTALLATION TYPICAL FIELD WIRING UNIT MODEL dBA Cooling Heating 018 TBD TBD 024 T...

Page 17: ...4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 105 T C 13 2 13 6 13 4 15 2 17 0 14 7 14 9 14 2 16 0 17 9 16 3 16 3 15 0 16 7 18 7 S C 11 9 11 3 9 6 9 7 7 8 13 3 13 0 11 3 11 5 8 9 14 8 14 8 13 1 13 3 1...

Page 18: ...21 8 21 5 20 8 23 2 25 5 S C 17 6 16 7 14 3 14 4 11 7 19 2 18 6 16 2 16 4 12 8 20 8 20 5 18 1 18 4 13 9 KW 1 9 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 1 115 T C 17 1 17 3 17 4 19 6 21 5...

Page 19: ...5 2 5 115 T C 21 0 21 3 20 9 23 4 26 4 22 3 22 3 21 3 24 0 26 9 23 6 23 4 21 8 24 5 27 4 S C 21 2 20 8 17 7 17 7 13 9 22 5 22 2 19 3 19 7 15 0 23 9 23 6 20 9 21 8 16 1 KW 2 5 2 5 2 5 2 6 2 7 2 6 2 6 2...

Page 20: ...5 2 19 7 32 0 31 8 27 1 27 0 20 7 KW 2 9 3 0 3 0 3 0 3 1 3 0 3 0 3 0 3 0 3 1 3 0 3 0 3 0 3 0 3 1 115 T C 27 8 27 6 27 5 30 7 34 0 29 3 29 1 28 1 31 5 34 9 30 8 30 5 28 7 32 3 35 8 S C 26 9 25 7 22 1 2...

Page 21: ...4 7 33 4 28 0 27 8 21 7 36 1 35 3 30 1 29 8 22 8 37 5 37 1 32 3 31 9 23 8 KW 3 6 3 6 3 6 3 6 3 7 3 6 3 6 3 6 3 6 3 7 3 6 3 6 3 6 3 7 3 7 115 T C 31 1 31 3 30 6 33 8 37 1 32 2 32 3 31 3 34 4 37 5 33 4...

Page 22: ...9 35 3 26 6 KW 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 4 0 115 T C 36 4 35 9 35 9 39 3 43 3 37 5 37 0 36 3 39 8 43 7 38 5 38 1 36 8 40 4 44 1 S C 37 2 35 7 30 7 30 4 23 4 38 3 37 3 32...

Page 23: ...7 52 6 58 0 63 4 S C 51 6 48 6 40 7 40 5 32 2 53 2 51 1 42 8 42 5 33 4 54 9 53 6 44 9 44 6 34 7 KW 3 6 3 6 3 6 3 6 3 7 3 6 3 6 3 6 3 7 3 7 3 6 3 6 3 6 3 7 3 7 95 T C 47 6 48 1 48 1 53 1 58 3 49 0 48...

Page 24: ...8 1 2 2 2 9 2 1 2 2 2 9 7 1 3 2 2 10 60 6 1 1 1 1 6 6 7 1 2 1 6 7 3 1 3 1 7 70 6 2 1 1 1 6 7 1 1 2 1 7 8 0 1 3 1 8 80 6 2 1 1 1 6 7 4 1 2 1 8 8 6 1 3 2 0 NOTE ALL CAPACITIES ARE NET KBTUH WITH INDOOR...

Page 25: ...9 1 6 1 9 10 6 1 6 1 9 80 8 0 1 5 1 6 8 6 1 6 1 6 9 3 1 6 1 7 NOTE ALL CAPACITIES ARE NET KBTUH WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil MBH KW COP FC MC PC24 1 00...

Page 26: ...Handler Coil MBH KW COP FC MC PC32 0 99 0 98 1 01 FC MC PC35 0 99 0 98 1 01 FC MC PC37 1 00 1 00 1 00 FC MC PC43 1 00 1 00 1 00 HC36 0 99 0 98 1 01 HC42 1 00 1 00 1 00 HD48 1 34 1 40 0 96 AHP36 1 00...

Page 27: ...LL CAPACITIES ARE NET KBTUH WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil MBH KW COP FC MC PC37 1 01 1 01 1 00 FC MC PC43 1 01 1 01 1 00 FC MC PC48 1 01 1 01 1 00 HC42 1...

Page 28: ...8 3 0 2 4 26 6 3 0 2 6 28 4 3 0 2 8 NOTE ALL CAPACITIES ARE NET KBTUH WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil MBH KW COP FC MC PC60 1 00 1 06 0 94 HC42 0 99 0 99 1...

Page 29: ...KBTUH WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 1000 CFM Air Handler Coil MBH KW COP FC MC PC48 1 00 0 95 1 04 FC MC PC60 1 00 1 02 0 99 HC60 1 00 1 02 0 99 HD60 0 98 0 85 1 16 MC62 1 00 0 9...

Page 30: ...8 3 4 56 3 4 8 3 5 56 8 4 7 3 5 80 54 7 5 2 3 1 55 2 5 2 3 1 55 6 5 1 3 2 40 60 51 9 4 3 3 5 51 7 4 3 3 5 51 4 4 3 3 5 70 50 6 4 8 3 1 51 1 4 7 3 2 51 7 4 7 3 2 80 49 3 5 2 2 8 50 6 5 1 2 9 51 9 5 0 3...