background image

TECHNICAL GUIDE

HORIZONTAL DISCHARGE 
SPLIT SYSTEM 
AIR CONDITIONERS

14 SEER – R-410A – 1 PHASE
2, 3, 4 NOMINAL TONS

MODELS: TCHE24, 36, 48

Due to continuous product improvement, specifications 
are subject to change without notice.
Visit us on the web at 

www.upgnet.com and www.york.com

Additional rating information can be found at 

www.ahridirectory.org

WARRANTY SUMMARY*

Extended 10-Years limited parts warranty.

Standard 10-Years limited compressor warranty.

Extended 10-Years limited parts warranty

 when product is

registered online within 90 days of purchase for replacement
or closing for new home construction.

*Does not apply to 3-Phase models, or Internet sales.

See Limited Warranty certificate in User's Information Manual for details.

FOR INSTALLATION IN ALL US REGIONS AND CANADA

Installation Allowed

®

5371951-YTG-A-0517

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The 14 SEER TCHE Series condensing unit is the outdoor part
of a versatile system of air conditioning. Optimized for the new
14 SEER Regional Minimum Efficiency and the high EER
required in the Southwest US, these outdoor units are specifi-
cally designed to be matched with York indoor coils, furnaces,
and air handlers to provide a complete system solution.

These remarkably compact units require only minimal service
and airflow clearances, allowing them to be positioned as close
as six inches (6") from the wall. This design allows the unit to be
located virtually anywhere – on the ground, roof, balcony, or
mounted to an outside wall. When installation footprint is lim-
ited, these units can be stacked two-high using the approved
stacking kit.

FEATURES

Performance -

 Optimized for the US DOE Southwest

Region and valid for installation in all US DOE Regions. 

Small Footprint -

 Compact “slim-line” design allows for easy

installation in tight spaces. Units can be stacked two-high
with approved stacking kit. 

QuietDrive™ System -

 The combination of a swept-wing

fan, rigid base pan, isolated compressor compartment, and
quiet scroll compressor reduce sound to as low as 70 dBA. 

Low Operating Sound Levels -

 The swept-wing condenser

fan in blow-through configuration provides for whisper-quiet
operation by allowing air to flow smoothly and efficiently
across the fan blades. 

Quality Condenser Coils -

 The coil is constructed of alumi-

num microchannel tubing and enhanced aluminum fins for
compact size and increased efficiency. 

Environmentally Friendly Refrigerant -

 The next genera-

tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion. 

Durable Cabinet -

 Heavy-gauge steel cabinet and tubular

base rails provide added support. 

Aesthetic Appearance -

 Powder paint “Champagne” color

provides an attractive retail finish. 

Agency Listed -

 Safety certified by CSA to UL 1995 / CSA

22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.

• Other Features:

– Factory installed spun copper filter drier

– High pressure and low pressure switches

– Accumulator and crankcase heater in all sizes

– Up to 200’ line set out of the box

– Zero lot line - only 6” minimum clearance from structure

Summary of Contents for TCHE24

Page 1: ...the ground roof balcony or mounted to an outside wall When installation footprint is lim ited these units can be stacked two high using the approved stacking kit FEATURES Performance Optimized for th...

Page 2: ...APHIC 14 TYPICAL FIELD WIRING 14 PERFORMANCE DATA 2 TON 15 PERFORMANCE DATA 3 TON 18 PERFORMANCE DATA 4 TON 20 NOMENCLATURE BRAND T T Factory Branded PRODUCT TYPE C C Air Conditioner US Northern or So...

Page 3: ...Hard Start Kit part number for each model No No No Fan Diameter Inches 23 23 23 Fan Motor Rated HP 1 4 1 4 1 4 Rated Load Amps 1 3 1 3 1 3 Nominal RPM 850 850 850 Nominal CFM 3200 3200 3050 Coil Face...

Page 4: ...for line set SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS System Charge for Various Matched Systems Outdoor Unit TCHE24S41S1 TCHE36S41S1 TCHE48S41S1 Required TXV 1 2 BA1 BA2 BA2 Indoor Unit 3 4 5 Additio...

Page 5: ...25 12 75 TCHE24S41S MVC12BN21 17 5 CF CM30B 775 24 0 18 4 15 25 12 75 TCHE24S41S MVC12BN21 17 5 CF CM36B 775 24 0 18 5 15 50 12 75 TCHE24S41S MVC14DN21 24 5 CF CM30D 750 24 0 18 0 15 50 12 75 TCHE24S4...

Page 6: ...S FC49D 21 0 1400 1800 1425 46 0 33 8 14 00 12 15 For rated condition information see the footnotes below the System Capacity Single Piece and Modular Air Handlers table 1 Requires a S1 2FD06700224 Bl...

Page 7: ...2 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU30C 825 23 8 18 3 14 50 12 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU30D 825 24 0 18 5 14 50 12 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU36C 825 23 8 18 9...

Page 8: ...5 CF CM CU30D 825 24 0 18 6 15 25 12 75 TCHE24S41S TM9Y120D20MP11 24 5 CF CM CU36D 825 24 0 19 1 15 25 12 75 TCHE24S41S TMLV060A12MP11 14 5 CF CM36A 775 24 0 18 5 15 25 12 75 TCHE24S41S TMLV080B12MP1...

Page 9: ...2 50 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU30D 900 24 0 19 1 15 00 12 50 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU36C 875 24 0 19 3 15 25 12 75 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU36D 900 24 0 19 5...

Page 10: ...1 21 0 FC38C 1200 35 8 27 2 15 50 12 75 TCHE36S41S TMLX100C16MP11 21 0 FC38C 1200 35 8 27 2 15 50 12 75 TCHE36S41S TMLX100C20MP11 21 0 FC38C 1200 35 6 27 0 15 25 12 75 TCHE36S41S TMLX120C20MP11 21 0 F...

Page 11: ...49D 1400 46 0 34 0 14 75 12 25 TCHE48S41S TMLX100C16MP11 21 0 FC49D 1400 46 0 34 0 14 75 12 25 TCHE48S41S TMLX100C20MP11 21 0 FC49D 1425 46 5 34 6 15 10 12 50 TCHE48S41S TMLX120C20MP11 21 0 FC49D 1425...

Page 12: ...cal Electrical Table See Price Pages or Source1 SmartSearch for the correct kit for each application Compressor Crankcase Heater Kit S1 025 A wrap around electrical resistance heater that warms the co...

Page 13: ...tely wired piped and assem bled Wiring pigtails shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be factory l...

Page 14: ...ALL OUTDOOR WIRING MUST BE WEATHERPROOF CAN BE STACKED TWO HIGH WITH APPROVED STACKING KIT AIRFLOW DIRECTION 28 06 7 50 18 73 LARGE CABINET ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC...

Page 15: ...2 14 2 23 6 22 7 19 4 18 6 15 0 25 2 25 1 21 3 20 0 15 9 K W 1 32 1 32 1 65 1 36 1 31 1 39 1 39 1 55 1 41 1 39 1 46 1 46 1 46 1 46 1 46 65 T C 24 6 23 6 26 5 25 8 27 4 24 6 24 6 25 9 26 5 28 2 24 7 2...

Page 16: ...100C16MP11 CF CM CU30D 1 00 1 06 0 94 TM8X100C16MP11 CF CM CU36C 1 00 1 09 0 94 TM8X100C16MP11 CF CM CU36D 1 00 1 09 0 94 TM8X100C20MP11 CF CM CU30C 0 99 1 04 0 99 TM8X100C20MP11 CF CM CU30D 1 00 1 06...

Page 17: ...94 TMLX100C20MP11 CF CM CU30C 0 99 1 04 0 99 TMLX100C20MP11 CF CM CU30D 1 00 1 06 1 00 TMLX100C20MP11 CF CM CU36C 0 99 1 08 0 99 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW TMLX100C20...

Page 18: ...21 8 35 6 35 6 30 1 29 4 22 8 37 0 38 4 32 3 31 3 23 7 K W 1 89 1 91 1 88 1 90 1 92 1 97 1 98 1 96 1 98 2 01 2 04 2 06 2 05 2 06 2 09 65 T C 33 2 35 8 35 8 38 8 41 5 34 7 36 9 36 8 39 8 42 3 36 2 37...

Page 19: ...FC38C 1 01 0 99 0 96 TM9V100C16MP11 FC38C 1 01 0 99 0 96 TM9V100C20MP11 FC38C 1 00 0 99 0 96 TM9Y080C16MP11 FC38C 1 00 0 99 0 96 TM9Y100C16MP11 FC38C 1 00 0 99 0 96 TM9Y100C20MP11 FC38C 1 00 0 99 0 9...

Page 20: ...26 4 46 1 42 0 36 0 33 0 27 2 47 4 43 9 37 4 34 1 28 0 K W 2 51 2 54 2 53 2 55 2 61 2 60 2 62 2 62 2 64 2 70 2 68 2 70 2 70 2 73 2 79 65 T C 44 7 47 1 47 4 49 7 52 4 46 2 48 2 48 4 50 5 53 2 47 7 49...

Page 21: ...97 TM9E120D20MP11 FC49D 1 01 1 02 0 98 TM9V100C20MP11 FC49D 1 00 0 99 0 99 TM9V120D20MP11 FC49D 1 00 1 00 0 97 TM9Y080C16MP11 FC49D 1 00 1 02 1 03 TM9Y100C16MP11 FC49D 1 00 1 02 1 03 TM9Y100C20MP11 F...

Page 22: ...ct to change without notice Published in U S A 5371951 YTG A 0517 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069...