Johnson Controls Unitary Products

APPLICATIONS AND ACCESSORIES

Refer to Price Manual for specific model numbers.

*  For Low Ambient and/or Long Lineset Applications, please see the acces-

sories listed below.

Non-Standard Lineset Applications - 

For installations with

reduced diameter or long linesets, refer to the current version of
the Piping Application Guide P/N 247077, available in the Appli-
cation Bulletins section on 

www.upgnet.com

.

OD Unit Anti Short Cycle Kit (10 Pack) S1-2TD08700124BK:

A time delay that prevents rapid compressor restarting as a
result of power interruption, limit switch operation, or thermostat
resetting. Not required for HP models, or for AC models with
factory electronic controls.

Standard Low Ambient Control Kit S1-2LA06700424:

 Allows

the use of air conditioning at low outdoor ambient temperatures
down to +20°

F (-7°

C). For use with all R-410A single stage AC

& HP models.

Advanced Low Ambient Control Kit S1-2LA04701024:

 Con-

tains the necessary components and controls to allow cooling
operation down to -20ºF (-29ºC). For use with all R-410A single
stage AC & HP models.

Low Pressure Switch Kit S1-2PS06700524:

 Provides field

installed low pressure (loss of charge) protection. Not required
for HP models, or for AC models with factory electronic con-
trols.

High Ambient Condenser Fan Motor S1-FHM****HT:

 Class F

70°

C motor to allow cooling operation up to 160ºF air entering

the condenser. For use with all R-410A single stage AC & HP
models containing R-410A refrigerant only.

Outdoor Communicating Board Kit (S1-33102952310):

 Elec-

tronic control upgrade for standard AC & HP units to provide
compatibility with the Residential Touch Screen Communicating
Control.

Start Assist Kit S1-2SA067*****:

 Provides increased compres-

sor starting torque for areas with low supply voltage. Required
for units with recip compressors when applied with indoor TXV,
and for all units when applied with long linesets or low ambient
kits. May be factory installed on select AC & HP units (see
Physical & Electrical Table). See Price Pages or Source1
SmartSearch for the correct kit for each application.

Compressor Crankcase Heater Kit (S1-025********):

 A wrap-

around electrical resistance heater that warms the compressor
sump, reducing the chance of liquid slugging on startup.
Required on all long lineset and low ambient applications. See
Price Pages or Source1 SmartSearch for the correct part for
each application.

Indoor Blower-Off Delay Kit S1-2FD06700224:

 Provides a 1-

minute blower-off delay at the end of the cooling cycle. May be
required for retrofits with non-Johnson Controls Unitary Prod-
ucts indoor units. This feature is factory-provided on all JCUP
indoor products.

Indoor TXV Kit S1-1TVM***:

 Thermal expansion valves pre-

cisely meter refrigerant for optimum performance over a wide
range of conditions. See System Charge Table, Price Pages, or
Source1 Smart Search for TXV part number for each AC & HP
model.

Cold Weather Charging Tent S1-CHGTENT01:

 Provides

warm environment to accurately service AC & HP systems in
ambient conditions 55ºF (13ºC) or colder.

Touch-up Paint S1-5130153****:

 Color matched aerosol paint

for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.

Compressor Sound Blanket S1-01007xxx000:

 A field

installed dense foam cover that provides 2dBA sound level
reduction. See Price Pages or Source1 SmartSearch for the
correct blanket for each application.

Thermostat - 

Compatible thermostat controls are available

through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with the York Hx™ Touch-
screen Thermostat (S1-THXU280*) available through Source1.
For more information, see the thermostat section of the Product
Equipment Catalog.

SOUND POWER RATINGS

Rated in accordance with ARI Standard 270.

Standard Application Limits*

Maximum Lineset Equivalent Length

200 Ft

Outdoor Ambient Temperature Limits

Cooling Operation

Maximum DB

120°

F

Minimum DB

50°

F

Cooling

Octave Band Sound Power Level (db re. 1-pW)

Model Number

63

125

250

500

1000

2000

4000

8000

dBA

SQI

TCHE24S41S1

73

78

69

67

65

60

57

58

70

19.1

TCHE36S41S1

74

77

68

67

66

61

58

58

71

19.1

TCHE48S41S1

75

81

70

68

66

61

58

58

72

19.0

Summary of Contents for TCHE24

Page 1: ...the ground roof balcony or mounted to an outside wall When installation footprint is lim ited these units can be stacked two high using the approved stacking kit FEATURES Performance Optimized for th...

Page 2: ...APHIC 14 TYPICAL FIELD WIRING 14 PERFORMANCE DATA 2 TON 15 PERFORMANCE DATA 3 TON 18 PERFORMANCE DATA 4 TON 20 NOMENCLATURE BRAND T T Factory Branded PRODUCT TYPE C C Air Conditioner US Northern or So...

Page 3: ...Hard Start Kit part number for each model No No No Fan Diameter Inches 23 23 23 Fan Motor Rated HP 1 4 1 4 1 4 Rated Load Amps 1 3 1 3 1 3 Nominal RPM 850 850 850 Nominal CFM 3200 3200 3050 Coil Face...

Page 4: ...for line set SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS System Charge for Various Matched Systems Outdoor Unit TCHE24S41S1 TCHE36S41S1 TCHE48S41S1 Required TXV 1 2 BA1 BA2 BA2 Indoor Unit 3 4 5 Additio...

Page 5: ...25 12 75 TCHE24S41S MVC12BN21 17 5 CF CM30B 775 24 0 18 4 15 25 12 75 TCHE24S41S MVC12BN21 17 5 CF CM36B 775 24 0 18 5 15 50 12 75 TCHE24S41S MVC14DN21 24 5 CF CM30D 750 24 0 18 0 15 50 12 75 TCHE24S4...

Page 6: ...S FC49D 21 0 1400 1800 1425 46 0 33 8 14 00 12 15 For rated condition information see the footnotes below the System Capacity Single Piece and Modular Air Handlers table 1 Requires a S1 2FD06700224 Bl...

Page 7: ...2 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU30C 825 23 8 18 3 14 50 12 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU30D 825 24 0 18 5 14 50 12 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU36C 825 23 8 18 9...

Page 8: ...5 CF CM CU30D 825 24 0 18 6 15 25 12 75 TCHE24S41S TM9Y120D20MP11 24 5 CF CM CU36D 825 24 0 19 1 15 25 12 75 TCHE24S41S TMLV060A12MP11 14 5 CF CM36A 775 24 0 18 5 15 25 12 75 TCHE24S41S TMLV080B12MP1...

Page 9: ...2 50 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU30D 900 24 0 19 1 15 00 12 50 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU36C 875 24 0 19 3 15 25 12 75 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU36D 900 24 0 19 5...

Page 10: ...1 21 0 FC38C 1200 35 8 27 2 15 50 12 75 TCHE36S41S TMLX100C16MP11 21 0 FC38C 1200 35 8 27 2 15 50 12 75 TCHE36S41S TMLX100C20MP11 21 0 FC38C 1200 35 6 27 0 15 25 12 75 TCHE36S41S TMLX120C20MP11 21 0 F...

Page 11: ...49D 1400 46 0 34 0 14 75 12 25 TCHE48S41S TMLX100C16MP11 21 0 FC49D 1400 46 0 34 0 14 75 12 25 TCHE48S41S TMLX100C20MP11 21 0 FC49D 1425 46 5 34 6 15 10 12 50 TCHE48S41S TMLX120C20MP11 21 0 FC49D 1425...

Page 12: ...cal Electrical Table See Price Pages or Source1 SmartSearch for the correct kit for each application Compressor Crankcase Heater Kit S1 025 A wrap around electrical resistance heater that warms the co...

Page 13: ...tely wired piped and assem bled Wiring pigtails shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be factory l...

Page 14: ...ALL OUTDOOR WIRING MUST BE WEATHERPROOF CAN BE STACKED TWO HIGH WITH APPROVED STACKING KIT AIRFLOW DIRECTION 28 06 7 50 18 73 LARGE CABINET ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC...

Page 15: ...2 14 2 23 6 22 7 19 4 18 6 15 0 25 2 25 1 21 3 20 0 15 9 K W 1 32 1 32 1 65 1 36 1 31 1 39 1 39 1 55 1 41 1 39 1 46 1 46 1 46 1 46 1 46 65 T C 24 6 23 6 26 5 25 8 27 4 24 6 24 6 25 9 26 5 28 2 24 7 2...

Page 16: ...100C16MP11 CF CM CU30D 1 00 1 06 0 94 TM8X100C16MP11 CF CM CU36C 1 00 1 09 0 94 TM8X100C16MP11 CF CM CU36D 1 00 1 09 0 94 TM8X100C20MP11 CF CM CU30C 0 99 1 04 0 99 TM8X100C20MP11 CF CM CU30D 1 00 1 06...

Page 17: ...94 TMLX100C20MP11 CF CM CU30C 0 99 1 04 0 99 TMLX100C20MP11 CF CM CU30D 1 00 1 06 1 00 TMLX100C20MP11 CF CM CU36C 0 99 1 08 0 99 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW TMLX100C20...

Page 18: ...21 8 35 6 35 6 30 1 29 4 22 8 37 0 38 4 32 3 31 3 23 7 K W 1 89 1 91 1 88 1 90 1 92 1 97 1 98 1 96 1 98 2 01 2 04 2 06 2 05 2 06 2 09 65 T C 33 2 35 8 35 8 38 8 41 5 34 7 36 9 36 8 39 8 42 3 36 2 37...

Page 19: ...FC38C 1 01 0 99 0 96 TM9V100C16MP11 FC38C 1 01 0 99 0 96 TM9V100C20MP11 FC38C 1 00 0 99 0 96 TM9Y080C16MP11 FC38C 1 00 0 99 0 96 TM9Y100C16MP11 FC38C 1 00 0 99 0 96 TM9Y100C20MP11 FC38C 1 00 0 99 0 9...

Page 20: ...26 4 46 1 42 0 36 0 33 0 27 2 47 4 43 9 37 4 34 1 28 0 K W 2 51 2 54 2 53 2 55 2 61 2 60 2 62 2 62 2 64 2 70 2 68 2 70 2 70 2 73 2 79 65 T C 44 7 47 1 47 4 49 7 52 4 46 2 48 2 48 4 50 5 53 2 47 7 49...

Page 21: ...97 TM9E120D20MP11 FC49D 1 01 1 02 0 98 TM9V100C20MP11 FC49D 1 00 0 99 0 99 TM9V120D20MP11 FC49D 1 00 1 00 0 97 TM9Y080C16MP11 FC49D 1 00 1 02 1 03 TM9Y100C16MP11 FC49D 1 00 1 02 1 03 TM9Y100C20MP11 F...

Page 22: ...ct to change without notice Published in U S A 5371951 YTG A 0517 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069...

Reviews: