MP Modular Air Handlers use Coil Only Ratings.

COOLING CAPACITY - With Air Handler Coils 

UNIT

MODEL

AIR HANDLER

COIL

MODEL

1

COOLING

MODEL

WIDTH

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

TCHE24S41S

AE30BX21

17.5

800

24.0

18.5

15.50

12.75

TCHE24S41S

AE36BX21

17.5

800

24.0

18.7

15.75

13.00

TCHE24S41S

AE36CX21

21.0

800

24.0

18.7

16.00

13.00

TCHE24S41S

AP30BX21

17.5

800

23.8

18.5

14.00

12.25

TCHE24S41S

AVC30BX21

17.5

825

24.0

18.6

15.75

13.00

TCHE24S41S

AVC36BX21

17.5

800

24.0

18.7

16.00

13.00

TCHE24S41S

AVC36CX21

21.0

800

24.0

18.6

16.00

13.00

TCHE24S41S

ME08BN21

17.5

CF/CM30B

825

24.0

18.6

15.50

12.75

TCHE24S41S

ME08BN21

17.5

CF/CM36B

775

24.0

18.4

15.75

13.00

TCHE24S41S

ME12BN21

17.5

CF/CM30B

825

24.0

18.6

15.50

12.75

TCHE24S41S

ME12BN21

17.5

CF/CM36B

825

24.0

19.1

15.75

13.00

TCHE24S41S

ME14DN21

24.5

CF/CM30D

825

24.0

18.5

15.75

13.00

TCHE24S41S

ME14DN21

24.5

CF/CM36D

825

24.0

19.1

16.00

13.00

TCHE24S41S

ME16CN21

21.0

CF/CM30C

800

24.0

18.5

15.00

12.50

TCHE24S41S

ME16CN21

21.0

CF/CM36C

825

24.0

19.0

15.00

12.50

TCHE24S41S

MVC08BN21

17.5

CF/CM30B

725

24.0

18.0

15.75

13.00

TCHE24S41S

MVC08BN21

17.5

CF/CM36B

750

24.0

18.3

15.25

12.75

TCHE24S41S

MVC12BN21

17.5

CF/CM30B

775

24.0

18.4

15.25

12.75

TCHE24S41S

MVC12BN21

17.5

CF/CM36B

775

24.0

18.5

15.50

12.75

TCHE24S41S

MVC14DN21

24.5

CF/CM30D

750

24.0

18.0

15.50

12.75

TCHE24S41S

MVC14DN21

24.5

CF/CM36D

825

24.0

19.1

16.00

13.00

TCHE24S41S

MVC16CN21

21.0

CF/CM30C

850

24.0

19.0

15.00

12.50

TCHE24S41S

MVC16CN21

21.0

CF/CM36C

850

24.0

19.0

15.25

12.75

TCHE36S41S

ME16CN21

21.0

FC38C

1200

36.0

27.2

16.00

13.00

TCHE36S41S

MVC16CN21

21.0

FC38C

1200

35.8

27.2

15.50

12.75

TCHE48S41S

ME14DN21

24.5

FC49D

1425

46.5

34.6

15.10

12.50

TCHE48S41S

ME20DN21

24.5

FC49D

1425

46.5

34.6

15.50

12.50

TCHE48S41S

MVC14DN21

24.5

FC49D

1175

45.5

31.8

15.50

12.75

TCHE48S41S

MVC20DN21

24.5

FC49D

1375

46.5

34.2

15.50

12.75

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240. 

Cooling MBH based on 80°

F entering air temperature, 50% RH (Relative Humidity), and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°

F outdoor ambient divided by the total electric power in watt-hours at those conditions.

SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total 
electric power input in watt-hours during the same period.

1. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.

Summary of Contents for TCHE24

Page 1: ...the ground roof balcony or mounted to an outside wall When installation footprint is lim ited these units can be stacked two high using the approved stacking kit FEATURES Performance Optimized for th...

Page 2: ...APHIC 14 TYPICAL FIELD WIRING 14 PERFORMANCE DATA 2 TON 15 PERFORMANCE DATA 3 TON 18 PERFORMANCE DATA 4 TON 20 NOMENCLATURE BRAND T T Factory Branded PRODUCT TYPE C C Air Conditioner US Northern or So...

Page 3: ...Hard Start Kit part number for each model No No No Fan Diameter Inches 23 23 23 Fan Motor Rated HP 1 4 1 4 1 4 Rated Load Amps 1 3 1 3 1 3 Nominal RPM 850 850 850 Nominal CFM 3200 3200 3050 Coil Face...

Page 4: ...for line set SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS System Charge for Various Matched Systems Outdoor Unit TCHE24S41S1 TCHE36S41S1 TCHE48S41S1 Required TXV 1 2 BA1 BA2 BA2 Indoor Unit 3 4 5 Additio...

Page 5: ...25 12 75 TCHE24S41S MVC12BN21 17 5 CF CM30B 775 24 0 18 4 15 25 12 75 TCHE24S41S MVC12BN21 17 5 CF CM36B 775 24 0 18 5 15 50 12 75 TCHE24S41S MVC14DN21 24 5 CF CM30D 750 24 0 18 0 15 50 12 75 TCHE24S4...

Page 6: ...S FC49D 21 0 1400 1800 1425 46 0 33 8 14 00 12 15 For rated condition information see the footnotes below the System Capacity Single Piece and Modular Air Handlers table 1 Requires a S1 2FD06700224 Bl...

Page 7: ...2 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU30C 825 23 8 18 3 14 50 12 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU30D 825 24 0 18 5 14 50 12 25 TCHE24S41S TM8Y120C20MP11 21 0 CF CM CU36C 825 23 8 18 9...

Page 8: ...5 CF CM CU30D 825 24 0 18 6 15 25 12 75 TCHE24S41S TM9Y120D20MP11 24 5 CF CM CU36D 825 24 0 19 1 15 25 12 75 TCHE24S41S TMLV060A12MP11 14 5 CF CM36A 775 24 0 18 5 15 25 12 75 TCHE24S41S TMLV080B12MP1...

Page 9: ...2 50 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU30D 900 24 0 19 1 15 00 12 50 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU36C 875 24 0 19 3 15 25 12 75 TCHE24S41S TPLC100C16MP12 21 0 CF CM CU36D 900 24 0 19 5...

Page 10: ...1 21 0 FC38C 1200 35 8 27 2 15 50 12 75 TCHE36S41S TMLX100C16MP11 21 0 FC38C 1200 35 8 27 2 15 50 12 75 TCHE36S41S TMLX100C20MP11 21 0 FC38C 1200 35 6 27 0 15 25 12 75 TCHE36S41S TMLX120C20MP11 21 0 F...

Page 11: ...49D 1400 46 0 34 0 14 75 12 25 TCHE48S41S TMLX100C16MP11 21 0 FC49D 1400 46 0 34 0 14 75 12 25 TCHE48S41S TMLX100C20MP11 21 0 FC49D 1425 46 5 34 6 15 10 12 50 TCHE48S41S TMLX120C20MP11 21 0 FC49D 1425...

Page 12: ...cal Electrical Table See Price Pages or Source1 SmartSearch for the correct kit for each application Compressor Crankcase Heater Kit S1 025 A wrap around electrical resistance heater that warms the co...

Page 13: ...tely wired piped and assem bled Wiring pigtails shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be factory l...

Page 14: ...ALL OUTDOOR WIRING MUST BE WEATHERPROOF CAN BE STACKED TWO HIGH WITH APPROVED STACKING KIT AIRFLOW DIRECTION 28 06 7 50 18 73 LARGE CABINET ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC...

Page 15: ...2 14 2 23 6 22 7 19 4 18 6 15 0 25 2 25 1 21 3 20 0 15 9 K W 1 32 1 32 1 65 1 36 1 31 1 39 1 39 1 55 1 41 1 39 1 46 1 46 1 46 1 46 1 46 65 T C 24 6 23 6 26 5 25 8 27 4 24 6 24 6 25 9 26 5 28 2 24 7 2...

Page 16: ...100C16MP11 CF CM CU30D 1 00 1 06 0 94 TM8X100C16MP11 CF CM CU36C 1 00 1 09 0 94 TM8X100C16MP11 CF CM CU36D 1 00 1 09 0 94 TM8X100C20MP11 CF CM CU30C 0 99 1 04 0 99 TM8X100C20MP11 CF CM CU30D 1 00 1 06...

Page 17: ...94 TMLX100C20MP11 CF CM CU30C 0 99 1 04 0 99 TMLX100C20MP11 CF CM CU30D 1 00 1 06 1 00 TMLX100C20MP11 CF CM CU36C 0 99 1 08 0 99 FURNACE MULTIPLIERS 2 TON Continued Furnaces Coil T C S C KW TMLX100C20...

Page 18: ...21 8 35 6 35 6 30 1 29 4 22 8 37 0 38 4 32 3 31 3 23 7 K W 1 89 1 91 1 88 1 90 1 92 1 97 1 98 1 96 1 98 2 01 2 04 2 06 2 05 2 06 2 09 65 T C 33 2 35 8 35 8 38 8 41 5 34 7 36 9 36 8 39 8 42 3 36 2 37...

Page 19: ...FC38C 1 01 0 99 0 96 TM9V100C16MP11 FC38C 1 01 0 99 0 96 TM9V100C20MP11 FC38C 1 00 0 99 0 96 TM9Y080C16MP11 FC38C 1 00 0 99 0 96 TM9Y100C16MP11 FC38C 1 00 0 99 0 96 TM9Y100C20MP11 FC38C 1 00 0 99 0 9...

Page 20: ...26 4 46 1 42 0 36 0 33 0 27 2 47 4 43 9 37 4 34 1 28 0 K W 2 51 2 54 2 53 2 55 2 61 2 60 2 62 2 62 2 64 2 70 2 68 2 70 2 70 2 73 2 79 65 T C 44 7 47 1 47 4 49 7 52 4 46 2 48 2 48 4 50 5 53 2 47 7 49...

Page 21: ...97 TM9E120D20MP11 FC49D 1 01 1 02 0 98 TM9V100C20MP11 FC49D 1 00 0 99 0 99 TM9V120D20MP11 FC49D 1 00 1 00 0 97 TM9Y080C16MP11 FC49D 1 00 1 02 1 03 TM9Y100C16MP11 FC49D 1 00 1 02 1 03 TM9Y100C20MP11 F...

Page 22: ...ct to change without notice Published in U S A 5371951 YTG A 0517 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069...

Reviews: