background image

036-21060-004-A-1102                                                                                                                                                                                                                             

Unitary Products Group

5

SIDE DUCT FLANGES

 - One-inch flanges replace the 

supply and return air panels on the rear of the unit to 
accommodate horizontal duct connections. These 
flanges can also be used individually for bottom supply/
horizontal return or horizontal supply/bottom return. They 
cannot be used on units with power exhaust.

BAROMETRIC RELIEF DAMPER

 - This damper acces-

sory can be used to relieve internal building air pressure 
on units with an economizer without power exhaust. This 
accessory includes a rain hood, a bird screen and a fully 
assembled damper. With bottom duct connections, the 
damper should be mounted over the opening in the 
return air panel. With horizontal ductwork, the accessory 
should be mounted on the return air duct.

ENTHALPY ACCESSORY CONTROL KIT

 - This kit 

contains the required components to convert a single 
enthalpy economizer to dual enthalpy.

BURGLAR BARS

 - Mount in the supply and return 

openings to prevent entry into the duct work.

FLUE EXHAUST EXTENSION KIT

 - In locations with 

wind or weather conditions which may interfere with 
proper exhausting of furnace combustion products, this 
kit can be installed to prevent the flue exhaust from 
entering nearby fresh air intakes.

WOOD SKID

 - Allows unit to be handled with 90” forks.

CO

2

 SENSOR

 - Senses CO

2

 levels and automatically 

overrides the economizer when levels rise above the 
present limits.

COIL GUARD

 - Customers can purchase a coil guard kit 

to protect the condenser coil from damage. This is not a 
hail guard kit. Model 1CG0415.

PHASE MONITORS 

- Designed to prevent unit damage. 

The phase monitor will shut the unit down in an out-of-
phase condition.

Summary of Contents for Sunline 2000

Page 1: ...verhead rigging Every unit is completely piped wired charged and tested at the fac tory to simplify the field installation and to provide years of depend able operation Powder paint cabinets provide a...

Page 2: ...HOOD 20 6 CENTER OF GRAVITY 20 7 ROOF CURB DIMENSIONS ALL MODELS 21 8 ROOF CURB BENEFITS 21 9 UNIT CURB AND APPLICATIONS 21 10 TYPICAL APPLICATION 22 11 TYPICAL ROOF TOP INSTALLATION 22 LIST OF TABLES...

Page 3: ...alarm on ignition failures compressor lockouts and repeated limit switch trips Nuisance Trip Protection and Strikes To prevent nuisance trouble calls the control board uses a three times you re out p...

Page 4: ...phase monitor will shut the unit down in an out of phase condition DIRTY FILTER SWITCH This kit includes a differential pressure switch that energizes the fault light on the unit thermostat indicating...

Page 5: ...y should be mounted on the return air duct ENTHALPY ACCESSORY CONTROL KIT This kit contains the required components to convert a single enthalpy economizer to dual enthalpy BURGLAR BARS Mount in the s...

Page 6: ...ust N Options 2 3 D Std Mtr Drive Motorized Damper P Options 2 4 Heat Type Nominal Heat Capacity F Std Mtr Drive 4 Filters Q Options 2 3 4 C00 Cooling Only No field installed electric heat G Std Mtr D...

Page 7: ...ontroller DFS APS Technicoat Cond Coil Phase Monitor CG CPC Controller DFS APS Technicoat Cond Coil Coil Guard CH CPC Controller DFS APS Technicoat Cond Coil Phase Monitor Coil Guard CJ CPC Controller...

Page 8: ...oil Phase Monitor Coil Guard Hinged Filter Door Tooless Access Panels EN Johnson UNT Controller DFS APS Technicoat Evap Cond Coils Hinged Filter Door Tooless Access Panels EP Johnson UNT Controller DF...

Page 9: ...Phase Monitor JC Johnson UNT Controller DFS APS Coil Guard JD Johnson UNT Controller DFS APS Phase Monitor Coil Guard JE Johnson UNT Controller DFS APS Technicoat Cond Coil JF Johnson UNT Controller D...

Page 10: ...coat Evap Coil Phase Monitor Hinged Filter Door Tooless Access Panels PL Novar ETC 3 Controller DFS APS Technicoat Evap Coil Coil Guard Hinged Filter Door Tooless Access Panels PM Novar ETC 3 Controll...

Page 11: ...Technicoat Evaporator Coil Phase Monitor Hinged Filter Door Tooless Access Panels UL Technicoat Evaporator Coil Coil Guard Hinged Filter Door Tooless Access Panels UM Technicoat Evaporator Coil Dirty...

Page 12: ...27 3 67 49 32 88 32 0 62 45 28 20 100 24 0 90 71 53 35 94 26 4 89 69 51 34 83 31 2 83 64 47 30 17 94 23 5 94 94 74 55 90 25 9 90 89 72 53 79 30 5 79 77 66 47 14 94 23 5 94 94 88 76 89 25 8 89 89 83 74...

Page 13: ...5 268 265 247 230 9000 73 362 24 6 219 164 110 341 27 1 214 158 105 295 31 8 200 144 93 68 334 23 9 287 228 171 116 315 26 2 282 222 166 111 275 30 7 261 206 151 96 63 311 23 2 311 296 236 178 295 25...

Page 14: ...1040 3 0 443 6 6 5 4 347 8 1 6 7 228 9 7 8 0 1070 2 0 489 6 9 5 7 396 8 5 7 0 280 10 2 8 3 1100 1 0 536 7 3 6 0 445 8 9 7 3 332 10 6 8 7 1130 0 0 583 7 6 6 2 495 9 3 7 6 385 11 0 9 0 DM300 UNIT DOWNF...

Page 15: ...ted in the respective blower performance table except for Horizontal Duct Connections Add these values due to less airflow resistance TABLE 7 BLOWER MOTOR AND DRIVE DATA MODEL SIZE BLOWER RANGE RPM MO...

Page 16: ...or 102mm optional QUANTITY PER UNIT 406 x 508 x 51 mm 2 16 x 20 x 2 in QUANTITY PER UNIT 406 x 635 x 51 mm 4 16 x 25 x 2 in QUANTITY PER UNIT 457 x 610 x 51 mm 3 14 x 20 x 2 in TOTAL FACE AREA m2 Ft 2...

Page 17: ...26 9 2 37 4 76 0 90 E054 40 4 2 56 2 94 0 100 E072 53 8 2 74 9 98 6 110 1 Electric Heat CORRECTION FACTORS 2 Dual element time delay fuse or HACR breaker NOMINAL VOLTAGE VOLTAGE KW CAP MULTIPLIER 415...

Page 18: ...AL BLOCK TERMINALS ON A LIMITED NUMBER OF THERMOSTATS 3 1 2 4 3 1 2 4 Second stage heating not required on single stage heating units Second stage cooling not required on single stage cooling units Ju...

Page 19: ...be installed outdoors Overhanging structures or shrubs should not obstruct condenser air discharge outlet Note Cool Only Models Units and ductwork are approved for zero clearance to combustible materi...

Page 20: ...are closed with sheet metal covers except when the unit includes a power exhaust option The cov ering consists of a black paper composition 3 Replace the side supply and return air compartment panels...

Page 21: ...ONS ALL MODELS Supply and Return air including duct support rails as shown are typical for Downflow duct applications For location of Sideflow duct applica tions on back of unit refer to Unit Dimensio...

Page 22: ...036 21060 004 A 1102 22 Unitary Products Group FIGURE 10 TYPICAL APPLICATION FIGURE 11 TYPICAL ROOF TOP INSTALLATION GAS ELECTRIC UNIT SHOWN...

Page 23: ...036 21060 004 A 1102 Unitary Products Group 23...

Page 24: ...o change without notice Printed in U S A 036 21060 004 A 1102 Copyright by Unitary Products Group 2002 All rights reserved Supersedes 036 21060 003 A 0802 Unitary 5005 Norman Products York OK Group Dr...

Reviews: