SIMPLE CONTROL CIRCUIT - A low voltage printed circuit
board contains a low voltage terminal strip. An additional set of
pin connectors is also provided so that field interface of external
controls will be simplified. Mate-n-lock plug connectors are
used where line and low voltage wires pass thru internal
bulkheads. This allows for easier troubleshooting and
component replacement. The electrical control box is not
located in the compressor compartment so the access cover
can be removed for troubleshooting without affecting the
normal system operating pressures.

AIR FILTERS - Units come standard with 2" throwaway filters.
The unit filter racks can accommodate 1" or 2" filters without
any modifications.

SYSTEM PROTECTION - Crankcase heaters and internal
compressor protection are standard on all compressors. Each
unit has suction line freezestats, low pressure switches, high
pressure switches and high temperature switches to protect all
system components. All units have bi-directional liquid line
filter-driers--except 575 volt units which has a discharge line
filter-drier. The units will operate on cooling down to 45

°

F

without any additional low ambient controls.

® 

SUNLINE 2000

 Dual Fuel Heat Pump

FEATURES

 - CONT’D.

Electrical Data...................................................................... 9
Field Wiring .......................................................................... 9
Unit Dimensions................................................................. 10
Corner Weights .................................................................. 12
Roof Curb Dimensions....................................................... 13
Field-Installed Accessories ................................................ 14
Roof-Top Installation .......................................................... 14

Description ........................................................................... 1
Features ............................................................................... 1
Ratings ................................................................................. 3
Physical Data ....................................................................... 4
Component Weights ............................................................ 4
Accessory Static Resistances ............................................. 4
Cooling Capacities ............................................................... 5
Heating Capacities............................................................... 7
Blower Performance ............................................................ 8
Blower Motor and Drive Data............................................... 8

TABLE OF CONTENTS

511.17-TG2Y 

2

Unitary Products Group

Summary of Contents for SUNLINE 2000 B1HN090

Page 1: ...unit and discard them If a bottom supply return is desired you simply remove the two bottom duct covers and discard them No panel cutting or swapping is required Convertible airflow design allows max...

Page 2: ...M PROTECTION Crankcase heaters and internal compressor protection are standard on all compressors Each unit has suction line freezestats low pressure switches high pressure switches and high temperatu...

Page 3: ...e refrigeration system including circulating fan heat BTU s per hour divided by the total electric input watts x 3 412 AFUE Annual Fuel Utilization Efficiency determined in accordance with DOE test pr...

Page 4: ...4 0 CHARGE REFRIGERANT 22 lbs oz SYSTEM NO 1 9 0 11 8 SYSTEM NO 2 9 0 13 8 NOTE Filter racks are adapted for 1 or 2 thick filters PHYSICAL DATA COMPONENT WEIGHTS BASIC COMPONENT MODEL BHN 090 120 Basi...

Page 5: ...W Sensible Capacity 1 MBH Total Cap 1 MBH Power Input2 KW Sensible Capacity 1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 3750 72 99 8 6 80 69 58 46...

Page 6: ...Total Cap 1 MBH Power Input2 KW Sensible Capacity 1 MBH Total Cap 1 MBH Power Input2 KW Sensible Capacity 1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71...

Page 7: ...56 6 8 68 6 9 79 7 5 93 8 3 CFM RET AIR F CAP KW OUTDOOR AIR TEMPERATURE F 72 RH 10 0 10 20 30 40 50 60 3000 55 MBH KW 30 7 1 41 7 2 52 7 4 64 7 6 77 7 9 93 8 3 109 8 7 127 9 6 70 MBH KW 29 7 4 39 7...

Page 8: ...0 1 61 1 66 1 55 1 44 1 81 1 69 1 10 2 10 1 96 MODEL BHN090 BOTTOM DUCT APPLICATIONS BLOWER PERFORMANCE 7 1 2 10 TON SUPPLY AIR BLOWER SPEED RPM CFM 3000 3500 4000 4500 5000 ESP BHP KW ESP BHP KW ESP...

Page 9: ...16 7 9 6 8 3 150 73 59 3 5 2 5 2 54 10 6 4 8 3 9 55 9 31 4 27 6 70 40 35 Dual numbers shown as 17 3 16 7 indicates compressor 1 2 respectively NOTES 1 Dual element time delay type 2 Maximum HACR break...

Page 10: ...must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined spac...

Page 11: ...3 Replace the side duct covers DETAIL X SIDE SUPPLY AND RETURN AIR DUCT OPENINGS CENTER OF GRAVITY B A R O M E T R I C R E L I E F R A I N H O O D R E A R V I E W L H E N D V I E W 2 3 3 8 2 3 3 4 A...

Page 12: ...310 378 302 120 1 612 322 416 492 382 BHN UNIT 6 POINT LOADS LBS TOTAL A B C D E F 090 1 237 155 186 217 264 226 189 120 1 612 199 246 293 347 291 236 NOTE These weights are with economizer and 24kW e...

Page 13: ...the curb from the roof All electrical connections can be made inside the curb ROOF CURB BENEFITS UNIT AND CURB APPLICATION ROOF CURB DIMENSIONS BHN 7 1 2 10 TON Supply and Return Air including duct s...

Page 14: ...rainhood and filters The outdoor air dampers open when the indoor fan motor is energized Damper capable of providing 0 thru 100 of outdoor return air opening MANUAL OUTDOOR DAMPER Provides 0 thru 35 o...

Page 15: ...511 17 TG2Y Unitary Products Group 15...

Page 16: ...up P O Box 1592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in U S A Copyright by York International Corporation 1998 All Rights Reserved Code EBY EGY 511 17 TG2Y Superse...

Reviews: