TYPICAL ROOF-TOP INSTALLATION

FIELD-INSTALLED ACCESSORIES

SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER -
Includes a slide-in / plug-in damper assembly with fully
modulating spring return motor actuator capable of introducing
up to 100% outdoor air, one outdoor air electronic enthalpy
sensor and a rainhood with filters. The rainhood is painted to
match the basic unit and must be field-assembled before
installation. Economizer dampers are 2% low leakage type. The
fixed outdoor air damper (shipped as standard equipment with
every unit) can be used for barometric relief on units with an
economizer.

DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER -
Includes the same damper system and rainhood with filters as
described for a single enthalpy economizer above except this
accessory contains two enthalpy sensors. It uses a differential
enthalpy control that compares the outdoor air versus the return
air. The logic module then optimizes the economizer operation
for additional savings over the single input economizer. The
fixed outdoor air damper (shipped as standard equipment with
every unit) can be used for barometric relief on units with an
economizer.

MOTORIZED AIR DAMPER - Includes slide-in / plug-in damper
assembly with rainhood and filters. The outdoor air dampers open
when the indoor fan motor is energized. Damper capable of
providing 0% thru 100% of outdoor return air opening.

MANUAL OUTDOOR DAMPER - Provides 0% thru 35% or 0%
thru 100% of outdoor return air opening (field adjustable).
Designed for duct mounted side or bottom supply / return
applications. Includes both hood assembly and filters.

ROOF CURB

 

This 14" high full perimeter roof curb is shipped

knocked down for field assembly and contains duct supports
and an insulated deck in the area under the unit’s outdoor
section.

ANTI-RECYCLE TIMER

 

- A timer to prevent unit compressors

from short cycling. It assures 5 minutes off time between
compressor cycles.

PROPANE CONVERSION KIT - Converts a gas-fired heater
from natural gas to propane. It contains main burner orifices, a
pilot orifice and a gas valve.

GAS PIPING - This kit contains 3/4" pipe nipples, fittings and
gas cock (including panel access gaskets) required for bottom
gas supply connection with external shut-off.

HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE)
- Provides orifices for proper furnace operation at altitudes up
to 6,000 ft. For propane applications, the propane conversion
kit will also be required.

WALL THERMOSTAT - The units are designed to operate with
24-volt electronic thermostats. All units operate with two stage
heat / two stage cool thermostats (with or without an
economizer).

511.17-TG2Y 

14

Unitary Products Group

Summary of Contents for SUNLINE 2000 B1HN090

Page 1: ...unit and discard them If a bottom supply return is desired you simply remove the two bottom duct covers and discard them No panel cutting or swapping is required Convertible airflow design allows max...

Page 2: ...M PROTECTION Crankcase heaters and internal compressor protection are standard on all compressors Each unit has suction line freezestats low pressure switches high pressure switches and high temperatu...

Page 3: ...e refrigeration system including circulating fan heat BTU s per hour divided by the total electric input watts x 3 412 AFUE Annual Fuel Utilization Efficiency determined in accordance with DOE test pr...

Page 4: ...4 0 CHARGE REFRIGERANT 22 lbs oz SYSTEM NO 1 9 0 11 8 SYSTEM NO 2 9 0 13 8 NOTE Filter racks are adapted for 1 or 2 thick filters PHYSICAL DATA COMPONENT WEIGHTS BASIC COMPONENT MODEL BHN 090 120 Basi...

Page 5: ...W Sensible Capacity 1 MBH Total Cap 1 MBH Power Input2 KW Sensible Capacity 1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 3750 72 99 8 6 80 69 58 46...

Page 6: ...Total Cap 1 MBH Power Input2 KW Sensible Capacity 1 MBH Total Cap 1 MBH Power Input2 KW Sensible Capacity 1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71...

Page 7: ...56 6 8 68 6 9 79 7 5 93 8 3 CFM RET AIR F CAP KW OUTDOOR AIR TEMPERATURE F 72 RH 10 0 10 20 30 40 50 60 3000 55 MBH KW 30 7 1 41 7 2 52 7 4 64 7 6 77 7 9 93 8 3 109 8 7 127 9 6 70 MBH KW 29 7 4 39 7...

Page 8: ...0 1 61 1 66 1 55 1 44 1 81 1 69 1 10 2 10 1 96 MODEL BHN090 BOTTOM DUCT APPLICATIONS BLOWER PERFORMANCE 7 1 2 10 TON SUPPLY AIR BLOWER SPEED RPM CFM 3000 3500 4000 4500 5000 ESP BHP KW ESP BHP KW ESP...

Page 9: ...16 7 9 6 8 3 150 73 59 3 5 2 5 2 54 10 6 4 8 3 9 55 9 31 4 27 6 70 40 35 Dual numbers shown as 17 3 16 7 indicates compressor 1 2 respectively NOTES 1 Dual element time delay type 2 Maximum HACR break...

Page 10: ...must be provided between any combustible material and the supply air ductwork for a distance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined spac...

Page 11: ...3 Replace the side duct covers DETAIL X SIDE SUPPLY AND RETURN AIR DUCT OPENINGS CENTER OF GRAVITY B A R O M E T R I C R E L I E F R A I N H O O D R E A R V I E W L H E N D V I E W 2 3 3 8 2 3 3 4 A...

Page 12: ...310 378 302 120 1 612 322 416 492 382 BHN UNIT 6 POINT LOADS LBS TOTAL A B C D E F 090 1 237 155 186 217 264 226 189 120 1 612 199 246 293 347 291 236 NOTE These weights are with economizer and 24kW e...

Page 13: ...the curb from the roof All electrical connections can be made inside the curb ROOF CURB BENEFITS UNIT AND CURB APPLICATION ROOF CURB DIMENSIONS BHN 7 1 2 10 TON Supply and Return Air including duct s...

Page 14: ...rainhood and filters The outdoor air dampers open when the indoor fan motor is energized Damper capable of providing 0 thru 100 of outdoor return air opening MANUAL OUTDOOR DAMPER Provides 0 thru 35 o...

Page 15: ...511 17 TG2Y Unitary Products Group 15...

Page 16: ...up P O Box 1592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in U S A Copyright by York International Corporation 1998 All Rights Reserved Code EBY EGY 511 17 TG2Y Superse...