background image

036-21578-002 Rev. B (0205)

Unitary Products Group

7

NOTES

Summary of Contents for PS9A12N040UP11

Page 1: ... warranty FEATURES Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit amp requirement for easy replacement applica tion Integrated control module for reliable economical opera tion High velocity filter and side return filter rack provided for easy fi...

Page 2: ...LE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PS9A12N040UP11 1200 A 14 1 2 13 1 4 12 1 8 6 1 4 PS9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PS9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PS9C16N080UP11 1600 C 21 19 3 4 18 1 2 8 7 8 PS9C20N080UP11 2000 C 21 19 3 4 18 1 2 8 7 8 PS9C16N100UP11 1600 C 21 19 3 4 ...

Page 3: ...0 45 75 PS9C16N080UP11 80 75 11 x 10 3 4 10 2 20 45 75 PS9C20N080UP11 80 75 11 x 11 1 12 7 20 40 70 PS9C16N100UP11 100 93 11 x 10 3 4 10 2 20 45 75 PS9C20N100UP11 100 93 11 x 11 1 12 7 20 40 70 PS9D20N120UP11 120 112 11 x 11 1 12 7 20 40 70 PS9D20N135UP11 135 127 11 x 11 1 12 7 20 45 75 Model Max Outlet Air Temp Nominal Airflow Cabinet Width Total Unit AFUE Min Wire Size awg 75 ft One Way Approxim...

Page 4: ... 1410 1350 1275 1170 1060 M HI 1165 1185 1175 1165 1150 1140 1100 1050 970 875 M LO 895 915 935 940 940 920 905 860 815 750 LOW 710 725 725 725 720 700 685 660 625 560 PS9C20N080UP11 PS9C20N100UP11 HIGH 2300 2210 2120 2020 1930 1830 1715 1595 1480 1350 M HI 1950 1900 1830 1755 1680 1595 1500 1390 1270 1155 M LO 1610 1545 1490 1440 1390 1315 1230 1155 1050 920 LOW 1325 1270 1225 1175 1105 1045 990 ...

Page 5: ... the following example Example For a 120 000 Btuh furnace with 2 return openings and operating on high speed blower it is found that total sys tem static is 0 58 w c To determine the system airflow com plete the following steps 1 Obtain the airflow values at 0 50 0 60 ESP Airflow 0 50 2285 CFM Airflow 0 60 2175 CFM 2 Subtract the airflow 0 50 from the airflow 0 60 to obtain airflow difference 2175...

Page 6: ...14 1 2 cabinets 1BR0317 For 17 1 2 cabinets 1BR0321 For 21 cabinets 1BR0324 For 24 1 2 cabinets EXTERNAL SIDE RETURN FILTER RACK 1SF0101 Fits all cabinet sizes Attaches to side of furnace cabinet in side return applications Holds any 16x25x1 permanent or disposable filter HIGH ALTITUDE PRESSURE SWITCHES These accessory kits may be used to convert units for high altitude operation Conversion must b...

Page 7: ...036 21578 002 Rev B 0205 Unitary Products Group 7 NOTES ...

Page 8: ...e without notice Printed in U S A 036 21578 002 Rev B 0205 Copyright by York International Corp 2005 All rights reserved Supersedes 036 21578 002 Rev A 0904 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

Reviews: