Johnson Controls Unitary Products

ACCESSORIES

Economizer for Downflow Applications 
(S1-2EE04710024, S1-2EE04710124) -

 Modulating inte-

grated economizer provides simultaneous operation between
mechanical cooling and economizer operation. Independent
blade design insures proper control and less than 1% leak
rate. Includes hood and mesh bird screen filter integrated into
the hood, dry bulb sensor and relief damper. Separate field
accessories of single/dual enthalpy kits are also available.

Economizer for Horizontal Applications 
(S1-2EE04710224, S1-2EE04710324) -

 Modulating inte-

grated economizer provides simultaneous operation between
the mechanical cooling and economizer operation. Indepen-
dent blade design insures proper control and less than 1%
leak rate. Includes hood and mesh bird screen filter inte-
grated into hood, dry bulb sensor and relief damper. Separate
field accessories of single enthalpy and dual enthalpy are
available.

Single/Dual Enthalpy Sensor (S1-HE-6863-0N00WS) -

Sensor replaces supply air temperature dry bulb sensor
standard in economizer kit. Provides improved economizer
operation by sensing the dry bulb temperature of indoor sup-
ply air plus the enthalpy content of the outdoor air.

Duct/Unit Mount CO2 Kit (S1-2AQ04700924) -

 Sensor kit

detects CO2 levels automatically and overrides the econo-
mizer when CO2 levels rise above the preset limits.

Wall Mount CO2 Kit (S1-2AQ04701024) -

 Sensor kit detects

CO2 levels automatically and overrides the economizer when
CO2 levels rise above the preset limits.

• Supply Air Temperature Sensor Kit (S1-TE-63616E-2D) -

Outdoor supply air temperature sensor kit used with econo-
mizers. 

Filter/Frame Kit (Kit provided) 
(S1-1FF0602, S1-1FF0601) - 

Kit contains the necessary

hardware to field install return air filters into the base unit. The
filter rack is suitable for either 1" or 2" filters.

Filter (S1-02647812000) - 

Washable 1” filter. Three filters

are required for B base units. Washable filters are included
inside shipped units for field installation.

Motorized Fresh Air Damper 
(S1-2MD04705224, S1-2MD04705124) -

 Designed for duct

mounted side supply/return and unit mounted down supply/
return applications. Damper capable of providing 0% through
50% of outdoor air (field supplied). Closes on power loss,
includes hood and screen assembly.

Rectangle to Round (Horizontal) Adapter 
(S1-1AK0110, S1-1AK0111) -

 Kit includes one supply and

one return air rectangle to round duct adapter. Adapters are
preformed and designed to fit over current horizontal duct
openings on the base unit. Transition is from rectangle to 12"
round for the 1AK0110 kit and from rectangle to 14" round for
the 1AK0111 kit.

Rectangle to Round (Downflow) Adapter 
(S1-1AK0108, S1-1AK0109) -

 Kit includes one supply and

one return air rectangle to round duct adapter. Adapters are
preformed and designed to fit into current downflow duct
openings on the roof curb. Transition is from rectangle to 16"
round for the 1AK0108 kit and from rectangle to 18" round for
the 1AK0109 kit.

Roof Curbs (S1-1RC0503, S1-1RC0501) -

 NRCA approved

curbs provide proper fit to base unit for rooftop installations.
Curbs are designed to be assembled through hinge pins in
each corner. Kit also provides seal strip to assure an air tight
seal. These are 8 inch high roof curbs.

Roof Curbs (S1-1RC0504, S1-1RC0502) - 

NRCA approved

curbs provide proper fit to base unit for rooftop installations.
Curbs are designed for assembly through hinge pins in each
corner. Kit also provides seal strip to assure air tight seal.
These are 14 inch high roof curbs.

Transition Curb Kits (S1-1TC01*) -

 Adapter  kits  to  allow

field use of pre-existing installed roof curbs to match PCE6
footprint to Affinity roof curbs, Carrier, Trane, or Goodman
curb footprints. Curb adapters are optional for current genera-
tion Carrier replacements but are recommended for previous
generation applications. Refer to the PCE6 price pages for
more details.

Electric Heat (Optional) -

 All PCE models use 6HK electric

heat kits, which are available in 230V/3/60 from 10 kW to 25
kW. Single point field wiring kits are available for all applica-
tions.

Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) -

 Pro-

vides 0% through 50% outdoor air capability (field adjust-
able). Designed for duct mounted side supply/return
applications and unit mounted down supply/return applica-
tions. Includes hood and screen assembly.

Transformer Kit (S1-2EC06700124) -

 Kit provides neces-

sary hardware to provide single phase models from factory
furnished 40 VA transformer capability to 75 VA transformer
capability. (Required on installations with economizer or
motorized damper).

Loss of Charge Switch (S1-2LC00024) -

 Kit provides Loss

of Charge switch and wiring to provide safe shutdown of com-
pressor.

Low Ambient Temperature Kit (S1-2LA04701024) -

 Kit pro-

vides necessary hardware to convert unit to operate in cool-
ing cycle down to 0º F. Standard unit operation 45º F.

Base Rail Hole Cover Kit (S1-1HC0101) -

 Kit provides nec-

essary hardware to close off openings in base rails to block
off openings, i.e. prevent animal entrance.

Single Point Wiring Kits for 6HK Electric Heat Applica-
tions (S1-SPWK*) -

 Kits provide field option for connecting

electrical power supplies to the field installed 6HK heat kits to
allow single point connections for single phase electric heat
applications with the exception of 25 kW kits.

Thermostat (S1-THXU280*)

 

Compatible thermostat con-

trols are available through accessory sourcing. For optimum
performance, these outdoor units are fully compatible with the
York Hx™ Touchscreen Thermostat (S1-THXU280*) avail-
able through Source1. For more information, see the thermo-
stat section of the Product Equipment Catalog.

Wall Thermostat -

 The units are designed to operate with

standard, 24-volt electronic non power stealing and electro-
mechanical thermostats. All units require the use of a multi-
stage conventional thermostat.

*

 

For additional kit numbers refer to the price pages.

Summary of Contents for PCE6B3631

Page 1: ...0A and tested prior to shipment Test stations using a state of the art computerized process system are used to insure product quality Refrigerant charge and component part numbers are verified via computers during assembly Vital run test statistics such as system pressure motor cur rents air velocity and temperature unit vibration and gas system safeties are monitored and recorded by the system to...

Page 2: ...ust be set to YES and a humidistat is connected from the low volt age R and HUM color coded leads During cooling operation if the humidity level is above the humidistat set point the indoor blower speed is reduced by approximately 15 Simple Control Circuit Field thermostat wiring connect to color coded leads using twist on wire connections Cooling controls use a contactor and a 2nd stage 24 VAC to...

Page 3: ...ot low Nox 3 Cabinet Size A small 35 x 51 B large 45 x 51 8 Generation Level 1 first generation 4 Nominal Air Conditioning Cooling Capacity BTUx1000 24 24 000 BTU etc 9 Revision Level A original release B second release Examples PCE6B4221A is a packaged A C with electric heat 16 SEER 3 1 2 ton large cabinet 230 volt single phase low NOx model first generation first release COMPONENT LOCATION 287 2...

Page 4: ...duct openings on the roof curb Transition is from rectangle to 16 round for the 1AK0108 kit and from rectangle to 18 round for the 1AK0109 kit Roof Curbs S1 1RC0503 S1 1RC0501 NRCA approved curbs provide proper fit to base unit for rooftop installations Curbs are designed to be assembled through hinge pins in each corner Kit also provides seal strip to assure an air tight seal These are 8 inch hig...

Page 5: ...reated galvanized steel shall provide a better paint to steel bond which resists corrosion and rust creep Powder paint finish shall provide superior corrosion resistance 1000 hour salt spray tested On Site Flexibility All model sizes shall use a compact design cabinet Field convertible duct connections from side shot to down shot allows the installer to have greater flexibil ity with less inventor...

Page 6: ...s to control refrigerant flow CONTROLS Simple Control Circuit Field thermostat wiring connects to color coded leads using twist on wire connections Cooling controls use contactor and relays for simple application and troubleshooting Mate n lock plug connectors are used Enhanced ECM indoor blower control is managed by a multi stage indoor blower control board that includes field adjust able speed t...

Page 7: ...pe Interlaced Interlaced Interlaced Evaporator Coil Data Face area Sq Ft 6 3 6 3 6 3 Rows 3 3 4 Fins per inch 16 16 16 Tube diameter 3 8 3 8 3 8 Circuitry Type Interlaced Interlaced Interlaced Refrigerant control TXV TXV TXV Condenser Fan Data Fan diameter Inch 26 26 26 Type Prop Prop Prop Drive type Direct Direct Direct No speeds 1 1 1 Motor HP each 1 3 1 3 1 3 RPM 850 850 850 Nominal total CFM 3...

Page 8: ...7 6 18 1 15 4 16 6 11 0 18 7 19 4 17 7 18 5 11 7 K W 4 23 4 22 4 19 4 19 4 13 4 17 4 18 4 18 4 15 4 10 4 11 4 14 4 17 4 12 4 07 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PCE6B36 CONDENSER ENTERING AIR TEMPERATURE ID CFM 2050 1800 1550 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 38 5 41 0 40 0 43 2 46 6 41 2 42...

Page 9: ...7 4 17 5 12 5 20 4 11 4 17 9 17 6 11 8 22 3 12 1 K W 3 98 4 10 3 98 3 91 3 89 3 99 4 05 4 00 3 92 3 93 4 00 4 01 4 02 3 93 3 97 COOLING PERFORMANCE DATA 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PCE6B48 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1400 1600 1800 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 46 5 54 3 55 5 56 6 59 6 47 9 54...

Page 10: ...2 24 3 27 5 24 6 25 9 18 4 25 1 26 7 25 2 27 5 19 6 K W 4 57 4 38 4 39 4 35 4 32 4 58 4 47 4 49 4 46 4 43 4 58 4 57 4 59 4 56 4 54 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCE6B60 CONDENSER ENTERING AIR TEMPERATURE ID CFM 600 800 1000 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 59 2 68 9 66 5 71 8 77 1 61 3 7...

Page 11: ...of duct 2 Units must be installed outdoors Overhanging structures or shrubs should not obscure outdoor air discharge outlet 3 Units may be installed on combustible floors made from wood or class A B or C roof covering materials Note For units applied with a roof curb the minimum clearance may be reduced from 1 inch to 1 2 inch between combustible roof curb material and this supply air duct INDOOR ...

Page 12: ...n Breakers for heaters are included in the 20kW and 25kW heater kits 1 MCA Minimum Circuit Ampacity 2 Maximum Over Current Protection per standard UL 1995 3 Fuse or HACR circuit breaker to be field installed 4 Single Point Connection Required ELECTRICAL DATA FOR 208 3 60 MULTI SOURCE POWER Model Compressor OD Fan Motor ID Blower Motor Electric Heat Option Multi Source Heater Kit Heater kW Stages H...

Page 13: ...29 0 45 69 0 NOTES Single source power MCA and MOP requirements are given here for reference if the unit is to be installed with a field installed single point power modification Breakers for heaters are included in the 20kW and 25kW heater kits ELECTRICAL DATA FOR 230 3 60 MULTI SOURCE POWER Model Compressor OD Fan Motor ID Blower Motor Electric Heat Option Multi Source Heater Kit Heater kW Stage...

Page 14: ...int Wiring Kit Unit Fuse Size A Heater Fuse Size A PCE6B3631 230 3 60 6HK06501025 S1 2SPWK031 30 30 6HK06501525 S1 2SPWK033 30 45 PCE6B4831 230 3 60 6HK06501025 S1 2SPWK032 35 30 6HK06501525 S1 2SPWK034 35 45 6HK06501825 S1 2SPWK034 35 50 6HK16502025 S1 2SPWK035 35 N A PCE6B6031 230 3 60 6HK06501025 S1 2SPWK032 45 30 6HK06501525 S1 2SPWK034 45 45 6HK06501825 S1 2SPWK034 45 50 6HK16502025 S1 2SPWK0...

Page 15: ...4 635 582 523 459 Low Cool A 1153 1095 1036 979 899 810 751 697 643 588 B 1015 952 884 802 709 646 582 528 467 402 C 882 805 741 625 556 501 415 359 297 228 D 805 718 642 523 436 376 294 247 193 118 Electric Heat A 1190 1133 1079 1026 953 861 798 742 689 638 B 1112 1054 991 928 840 760 701 648 591 532 C 955 886 821 721 642 584 508 453 391 324 D 856 776 708 591 516 459 375 321 262 191 48 High Cool ...

Page 16: ...2 0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 48 4 0 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08 1800 0 08 0 04 0 09 1900 0 09 0 05 0 10 2000 0 09 0 05 0 11 60 5 0 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08...

Page 17: ...OOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324 001 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0390 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT CONDENSATE DRAIN ...

Page 18: ...s Inc All rights reserved Supersedes 5291656 YTG D 0817 York International Corp 5005 York Drive Norman OK 73069 UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT ROOF CURB ROOF CONDENSATE DRAIN A0389 001 ...

Reviews: