Physical and electrical data
Table 2: Physical and electrical data
Model
HMH72B241S
HMH72B361S
HMH72B481S
HMH72B601S
Unit supply voltage
208/230 V, 1
phase, 60 Hz
208/230 V, 1
phase, 60 Hz
208/230 V, 1
phase, 60 Hz
208/230 V, 1
phase, 60 Hz
Normal voltage range (V)
198 to 253
198 to 253
198 to 253
198 to 253
Minimum circuit ampacity (A)
15
23
36
37
Maximum overcurrent device (A)
25
35
50
50
Minimum overcurrent device (A)
15
23
36
37
Compressor type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Compressor rated load (A)
11.0
16.1
26.0
26.5
Compressor locked rotor (A)
n/a
n/a
n/a
n/a
Crankcase heater (base heater)
Yes
Yes
Yes
Yes
Factory discharge muffler
Yes
Yes
Yes
No
HS kit required with TXV
N/A
N/A
N/A
N/A
Fan motor type
ECM
ECM
ECM
ECM
Fan motor quantity
1
1
2
2
Fan motor rated HP
1/12
1/6
1/6
1/6
Fan motor nominal RPM
880
810
850
850
Fan motor nominal CFM
1,825
2,350
3,525
3,525
Coil face area (sq. ft)
6.1
8.3
14.0
14.0
Coil rows deep
2
2
2
2
Coil fins per inch
18
19
17
18
Liquid lineset outdoor (field installed)
3/8
3/8
3/8
3/8
Vapor lineset outdoor (field installed)
5/8
3/4
7/8
7/8
Unit charge (lb-oz)
4-7
6-3
8-15
8-9
Charge (oz/ft)
0.38
0.38
0.60
0.60
Operating weight (lb)
112
157
227
251
Note:
• The normal voltage range is rated in accordance with AHRI Standard 110-2012, utilization
range A.
• Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
• Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent
protection.
• The unit charge provided is less than the system total charge required. Select the
appropriate indoor section and lineset length charge additions to calculate additional
charge required and total system charge.
• For applications with non-standard vapor line sizes, see
.
YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump
8
Johnson Controls Ducted Systems