Table 16: Heating performance data - 5 ton - air temperature (°F) entering outdoor unit
Outdoor unit model: HMH72B601S
ID CFM
Air temperature (°F)
1500
1750
2000
Entering
outdoor unit
Entering
indoor coil
MBH
COP
kW
MBH
COP
kW
MBH
COP
kW
60
37.6
2.65
4.16
39.0
2.73
4.18
40.4
2.82
4.20
70
34.9
2.34
4.38
35.7
2.37
4.41
38.7
2.56
4.43
17
80
31.5
2.00
4.62
34.3
2.14
4.69
37.0
2.28
4.76
60
33.6
2.44
4.04
35.1
2.52
4.07
36.6
2.61
4.11
70
30.9
2.14
4.23
31.6
2.17
4.27
34.6
2.35
4.31
10
80
27.1
1.79
4.45
29.9
1.93
4.53
32.6
2.07
4.62
60
27.8
2.12
3.85
29.5
2.21
3.91
31.1
2.30
3.97
70
25.2
1.84
4.02
25.7
1.85
4.08
28.7
2.03
4.14
0
80
20.8
1.45
4.20
23.6
1.60
4.31
26.3
1.75
4.42
Note:
• All capacities include indoor fan heat. kW values are for the system (o indoor).
21
YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump