OPTIONAL PARTS
3-4
TC-17005-rev.1
3.4 Air Outlet Shutter Plate: PI-160K3
Blockable Portion and Components
Example:
• Near the Wall: 3-Way Outlet
• In a Corner: 2-Way Outlet
• In Rectangular Room: 2-Way Outlet
NOTES:
1. If 3-way outlets are used, air quality will be decreased by about 3 to 5%, and within the operation range
of the unit, there will be no major difference in particular, in comparison with the 4-way outlet. However,
the electromagnetic interference (EMI) will increase by about 1 to 5dB(A).
2. Refer to the “Installation Manual for Air Outlet Shutter Plate” for installation details.
Dimensional Data
Installation State
18-1/2 [470]
20-1/2 [520]
3-5/8 [92]
3/8 [10]
2-1/2 [63]
B
Condensate Pan
Side Plate
Electrical Control Box
Shutter Plate
Sheet
Shutter Plate
Sheet
Side Plate
Condensate Pan
Indoor Unit
Insulation
0.024 [0.6]
Adhesive
Surface
Nonwoven
Fabric
Enlarged View from B
Attach the sheet to
match the corner of unit.
Do not attach the adhesive
surface to the indoor unit
insulation.
If adhered, the condensate
pan cannot be removed.
Shutter Plate
Sheet
Specifications
Model
Item
PI-160K3
Applicable Indoor Unit Model
((H,Y,C)IC4**B21S)
MBH
008 to 048
Quantity per Unit
1
Material
Shutter Plate
Polyethylenes
Sheet
Non-woven Fabric (UL94V-0)
Unit: inch [mm]