SECTION X: WIRING DIAGRAM

 FIGURE 14:  

Wiring Diagram - Single Phase

C

R

S

S

C

R

FAN

MOTOR

GND

5

2

1

C

HERM

FAN

HIGH VOLTAGE FACTORY WIRING
LOW VOLTAGE FACTORY WIRING
OPTIONAL WIRING
FIELD WIRING, LINE VOLTAGE

DUAL

CAPACITOR

HPS

SR

SC

JUNCTION
BOX

 
TURN OFF ELECTRICAL POWER BEFORE
SERVICING TOPREVENT POSSIBLE DAMAGE
TO THE EQUIPMENT AND POSSIBLE
PERSONAL INJURY.
 
 
 
TO PREVENT ELECTRICAL SHOCK OPEN
REMOTE DISCONNECT SO ELECTRICAL
SUPPLY TO AIR CONDITIONER IS SHUT OFF.
 
     COMPONENTS SHOWN IN DASHED
     LINES ARE OPTIONAL.
 
     DUAL CAPACITOR SHOWN SEPARATE
     CAPACITORS MAY BE USED ON
     ACTUAL UNIT.
 
     WIRING MUST CONFORM TO
     NATIONAL AND LOCAL CODES.
 
     IF ANY OF THE ORIGINAL WIRE
     SUPPLIED WITH THIS UNIT MUST BE
     REPLACED, IT MUST BE REPLACED
     WITH TYPE 105°C. THERMOPLASTIC
     OR ITS EQUIVALENT.
 
     WHERE POWER SUPPLY HAS ONE (1)
     230 VOLT CONDUCTOR AND ONE (1)
     NEUTRAL CONDUCTOR, CONNECT L2
     OF CONTACTOR TO NEUTRAL.
 

GND.

24 VAC

CONTROL

CIRCUIT

(20 VA MIN.)

208-230 VAC 60 Hz 1 PHASE SUPPLY
220-240 VAC 50 Hz 1 PHASE SUPPLY

USE

COPPER

CONDUCTORS

ONLY

CONTACTOR

GND.
LUG

HS

CCH

HPS    - HIGH PRESSURE SWITCH
CCH    - CRANKCASE HEATER
HS     - HEATER SWITCH
SR     - START RELAY
SC     - START CAPACITOR
CC     - CONTACTOR COIL

DANGER - SHOCK HAZARD

CAUTION

1

2

3

4

5

BLK

BLK

BLK

BRN

BLK

RED

RED

BRN

RED

RED

GRN

BRN

BRN

RED

YEL

RED

YEL/PNK

YEL/PNK

BLK

BLK

BLK

T1

T2

L1

L2

CC

COMPRESSOR

MOTOR

BLU

BLU

2

5

1

1

1

167242-UWD-E-0113

Summary of Contents for GCGA SERIES

Page 1: ...ndoor out door unit combinations elevation differences or total line lengths Refer to Application Data covering General Piping Recommendations and Refrigerant Line Length Part Number 247077 SECTION II...

Page 2: ...ion must be observed to ensure a system that will give maximum performance with minimum service 4 The unit should not be operated at outdoor temperatures below 50 F without an approved low ambient ope...

Page 3: ...for approved system combinations as specified in tabular data sheet The initial charge given is applicable for total tubing lengths up to 15 feet 4 6 m See Application Data Part Number 247077 for inst...

Page 4: ...one quarter turn counterclockwise to open Do not overturn or the valve stem may break or become damaged See PRECAU TIONS DURING BRAZING SERVICE VALVE 8 Replace the Schrader core in the liquid and vap...

Page 5: ...s as a reservoir c Bulb should be insulated using thermal insulation provided to protect it from the effect of the surrounding ambient tempera ture Cover completely to insulate from air stream SECTION...

Page 6: ...r than the rec ommended value Remove recover charge if the measured liquid pressure is above the recommended value Condenser subcooling is obtained by calculating the difference of the saturated refri...

Page 7: ...75 49 90 57 105 65 120 72 135 79 150 85 165 90 76 49 91 58 106 66 121 73 136 79 151 85 166 91 77 50 92 58 107 66 122 73 137 80 152 86 167 91 78 50 93 59 108 67 123 74 138 80 153 86 168 91 79 51 94 60...

Page 8: ...lace it on an out side wall or where it is exposed to the radiant effect from exposed glass or appliances drafts from outside doors or supply air grilles 6 Route the 24 volt control wiring NEC Class 2...

Page 9: ...WER WIRING CONTACTOR TERMINALS COIL GND LUG C Y R G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS 2 FURNACE OR AIR HANDLER TERMINAL BLOCK ROO...

Page 10: ...actor R 24 Volt Hot Heat XFMR R 24 Volt Hot Heat XFMR E W1 Emergency Heat E W1 Emergency Heat AUX Auxiliary Heat R 24 Volt Hot Cool XFMR Y2 Second Stage Compressor Connection of the C terminal 24 Volt...

Page 11: ...terminal 24 Volt common is optional when used with batteries Thermostat Installer Setup 0170 System Type must be set to 1 1 Heat 1 Cool Conventional Refer to AH documentation for W1 and W2 electric he...

Page 12: ...ct the owner on proper operation and maintenance of all other system components MAINTENANCE 1 Dirt should not be allowed to accumulate on the outdoor coils or other parts in the air circuit Clean as o...

Page 13: ...TORS MAY BE USED ON ACTUAL UNIT WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED IT MUST BE REPLACED WITH TYPE 105 C THERMOPLASTIC O...

Page 14: ...2 T1 24 VAC CTRL CIRCUIT 20VA MIN BLU BLU RED BLK BRN RED BLK GND LUG GND CONTACTOR OPTIONAL LOW VOLTAGE WIRING 2 3 FIELD WIRING CTRL CIRCUIT BLK YEL PNK YEL PNK HPS COLOR CODE BLK BLACK BLU BLUE BRN...

Page 15: ...LL BE REMOVED IF LOW AMBIENT KIT IS INSTALLED YELLOW WIRE WILL BE REMOVED IF PRESSURE SWITCH KIT IS INSTALLED IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED IT MUST BE REPLACED W...

Page 16: ...548086 XIM C 0814 16 Johnson Controls Unitary Products NOTES...

Page 17: ...f applicable Electrical Line Voltage Outdoor Unit Model Outdoor Unit Serial Filter Thermostat Accessories Filter Location s Connections Per Installation Instructions and Local Codes Gas piping is conn...

Page 18: ...th the owner s manual Explain thermostat use and programming if applicable to owner Cycle Test Operate the unit through several heating cycles if applicable from the thermostat noting and correcting a...

Reviews: