036-21318-002 Rev. A (0106)
Unitary Products Group
23
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EABA-F030S
EVAPORATOR COIL MODEL NO
F2RP/F2FP036
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
850
1050
1250
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
35.4
2.72
3.82
35.7
2.71
3.87
35.9
2.69
3.91
70
33.9
2.82
3.53
35.1
2.83
3.64
35.7
2.84
3.69
80
32.5
2.90
3.29
34.7
2.93
3.48
35.6
2.95
3.54
47
60
29.6
2.63
3.31
29.9
2.63
3.34
30.1
2.63
3.35
70
28.0
2.72
3.02
29.0
2.74
3.10
29.5
2.76
3.14
80
26.5
2.80
2.77
28.2
2.84
2.92
29.0
2.87
2.96
40
60
24.7
2.50
2.90
25.4
2.54
2.94
25.6
2.56
2.93
70
23.3
2.60
2.63
24.1
2.63
2.69
24.4
2.66
2.69
80
22.0
2.71
2.38
22.9
2.73
2.46
23.2
2.76
2.47
30
60
21.5
2.38
2.65
22.3
2.41
2.72
22.7
2.44
2.73
70
19.7
2.43
2.37
20.6
2.47
2.45
21.1
2.51
2.47
80
17.9
2.51
2.09
18.9
2.56
2.16
19.5
2.61
2.19
17
60
17.5
2.36
2.17
17.7
2.40
2.17
18.0
2.47
2.14
70
15.8
2.42
1.91
16.3
2.47
1.94
16.7
2.53
1.94
80
14.1
2.49
1.67
14.8
2.53
1.72
15.4
2.59
1.74
10
60
14.4
2.18
1.94
15.2
2.23
2.00
15.7
2.29
2.01
70
13.0
2.22
1.72
13.6
2.27
1.77
14.2
2.33
1.79
80
11.6
2.25
1.51
12.0
2.30
1.53
12.6
2.36
1.57
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
N1AHB1206
G2FD030(S,H)17
1.01
1.01
0.99
F2RP/F2FP030
0.99
0.99
1.00
G2FD030(S,H)17
1.01
1.01
0.99
G2FD035(S,H)14
1.01
1.01
0.99
G2FD036(S,H)17
1.01
1.02
1.00
G2FD036(S,H)21
1.02
1.02
1.00
G1HD036
1.02
1.02
1.00
G1NA030S17H
1.01
1.02
0.99
G1NA030S21B
1.01
1.02
0.99
G1UA03614
1.01
1.02
1.00
G1FA03614
1.01
1.02
1.00
G1UA036S17,21
1.01
1.01
0.99
G1FA036S17,21
1.01
1.01
0.99