036-21318-002 Rev. A (0106)
Unitary Products Group
13
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
EBBA-F024S
INDOOR COIL MODEL NO.
F2RP/F2FP030
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
650
850
1050
ID DB (°F)
85
80
75
70
85
80
75
70
85
80
75
70
ID WB (°F)
72
67
62
57
72
67
62
57
72
67
62
57
75
T.C.
26.6
24.3
22.4
20.0
27.0
24.7
22.7
20.3
27.1
24.8
22.8
20.9
S.C.
15.7
15.7
15.0
15.8
16.4
16.4
15.8
16.6
16.8
16.8
16.2
17.4
KW
2.20
2.12
2.06
1.97
2.21
2.13
2.07
1.99
2.21
2.14
2.08
2.01
85
T.C.
25.7
23.5
21.5
19.4
26.1
23.8
21.9
19.8
26.2
23.9
22.0
20.0
S.C.
15.8
15.8
15.1
16.1
16.7
16.7
16.0
17.0
17.1
17.1
16.5
17.4
KW
2.35
2.25
2.18
2.11
2.37
2.27
2.19
2.12
2.37
2.27
2.20
2.12
95
T.C.
23.9
21.7
20.1
17.9
24.2
22.0
20.4
18.2
24.3
22.1
20.5
18.6
S.C.
15.5
15.4
15.0
15.5
16.5
16.5
15.9
16.6
17.0
17.0
16.4
17.1
KW
2.50
2.40
2.30
2.21
2.51
2.41
2.33
2.22
2.52
2.42
2.34
2.25
105
T.C.
21.7
19.7
18.2
16.4
21.9
20.1
18.5
16.8
22.1
20.2
18.6
17.0
S.C.
15.0
15.0
14.3
15.1
16.1
16.2
15.2
15.5
16.7
16.6
15.6
15.7
KW
2.64
2.51
2.42
2.32
2.65
2.53
2.44
2.35
2.66
2.53
2.45
2.37
115
T.C.
19.5
17.8
16.3
14.8
19.8
18.1
16.7
15.2
19.9
18.1
17.0
15.4
S.C.
14.4
14.3
13.6
13.7
15.5
15.4
14.5
14.1
15.9
15.8
14.7
14.2
KW
2.74
2.61
2.51
2.41
2.76
2.62
2.54
2.45
2.77
2.64
2.56
2.46
125
T.C.
17.3
15.9
14.5
13.2
17.7
16.1
15.0
13.6
17.7
16.0
15.3
13.8
S.C.
13.8
13.6
12.9
12.2
14.9
14.6
13.7
12.7
15.1
15.0
13.7
12.7
KW
2.84
2.72
2.61
2.50
2.87
2.72
2.65
2.55
2.88
2.74
2.68
2.55
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
N1AHB0806
G2FD030(S,H)17
1.00
0.96
1.01
F2RP/F2FP024
0.97
0.98
0.98
G1FA030S14
0.98
0.98
1.00
G1FA036S17,21
1.00
0.96
1.01
G1HD024
0.98
0.98
0.99
G1NA030S17H
1.02
0.96
1.01
G1NA030S21B
1.02
0.96
1.01
G1UA030S14
0.98
0.98
1.00
G1UA036S17,21
1.00
0.96
1.01
G2FD024(S,H)14,17
0.97
0.94
0.98
G2FD030(S,H)17
1.00
0.96
1.01
G2FD035(S,H)14
1.00
0.96
1.01