036-21318-002 Rev. A (0106)
Unitary Products Group
21
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. EBBA-F018S
EVAPORATOR COIL MODEL NO. F2RP/F2FP018
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
500
650
800
MBTUH
KW
C.O.P.
MBTUH
K
C.O.P.
MBTUH
KW
C.O.P.
60
60
21.1
1.70
3.66
21.8
1.70
3.76
22.0
1.57
4.11
70
20.1
1.73
3.42
21.0
1.74
3.53
21.3
1.62
3.86
80
19.0
1.76
3.16
20.0
1.79
3.28
20.6
1.68
3.60
47
60
17.8
1.62
3.22
18.0
1.64
3.21
18.1
1.54
3.43
70
16.5
1.67
2.91
17.0
1.69
2.96
17.3
1.58
3.21
80
15.2
1.72
2.60
16.0
1.74
2.70
16.4
1.63
2.97
40
60
13.6
1.30
3.05
15.5
1.60
2.84
16.1
1.50
3.15
70
12.6
1.49
2.49
14.5
1.64
2.59
14.4
1.54
2.73
80
11.6
1.98
1.73
13.5
1.70
2.34
12.7
1.87
2.00
30
60
13.1
1.54
2.50
13.5
1.55
2.55
13.2
1.42
2.72
70
12.0
1.58
2.22
12.4
1.60
2.28
12.5
1.49
2.46
80
10.8
1.62
1.94
11.4
1.66
2.01
11.8
1.57
2.21
17
60
9.7
1.43
1.99
10.2
1.45
2.06
10.4
1.37
2.21
70
8.6
1.51
1.66
9.1
1.50
1.78
9.3
1.46
1.88
80
7.5
1.61
1.36
8.0
1.56
1.50
8.3
1.55
1.58
10
60
8.1
1.35
1.77
8.6
1.38
1.82
8.9
1.30
2.01
70
6.9
1.39
1.46
7.5
1.43
1.53
7.9
1.35
1.71
80
5.6
1.43
1.16
6.3
1.48
1.25
6.9
1.41
1.43
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
N1AHB0806
G2FD024(S,H)14,17
1.00
0.98
1.02
F2RP/F2FP024
1.00
0.98
1.01
G2FD024(S,H)14,17
1.00
0.98
1.02
G1HD024
1.01
0.98
1.03
G1NA030S17H
1.01
1.01
1.00
G1NA030S21B
1.01
1.01
1.00
G1UA024S14,17
0.99
0.99
1.00
G1FA024S14,17
0.99
0.99
1.00
G1UA030S14
1.00
0.98
1.02
G1FA030S14
1.00
0.98
1.02