Unitary Products Group

installed dirty filter indicator switch, an air-proving switch, 
an Outside Air Humidity sensor, a Return Air Humidity 
sensor, an Inside IAQ sensor, and an Outside Air IAQ 
sensor. Construction mode operation, 365-day real time 
clock with 7 day programming plus holiday scheduling is 
built-in. Two different modes of demand ventilation are 
achieved through the INTELLI-Comfort™ using CO

2

 sen-

sors. It uses an inside CO

2

 sensor to perform Demand 

Ventilation. It can also use an Outside CO

2

 sensor to per-

form Differential Demand Ventilation. It uses a Patented 
Comfort Ventilation algorithm to provide comfortable ven-
tilation air temperature. The patented economizer-loading 
algorithm will protect the equipment when harsh operating 
conditions exist. Humidity in the occupied space or return 
duct can be monitored and controlled via humidity sen-
sors and the on-board connection for hot gas re-heat sys-
tem.  It uses the INTELLI-Start™ algorithm to maximize 
energy savings by recovering the building from the Unoc-
cupied Setpoints to the Occupied Setpoints just in time for 
the Occupied Time Period to begin.  The 

Simplicity

®

 

INTELLI-Comfort™ balances space temperature, ventila-
tion air temperature, CO

2

 and humidity for ultimate com-

fort.

Simplicity

®

 INTELLI-Comfort™ with MOD LINK CON-

TROL -

 The York® 

Simplicity

®

 INTELLI-Comfort™ with 

Mod Link control is factory installed.  It includes all the 
features of the INTELLI-Comfort™ control with an addi-
tional control to translate communications from MOD-
BUS to the BACnet MSTP protocol.

Novar® BAS CONTROL -

 The Novar® ETC-3 building 

automation system controller is factory installed. 
Includes supply air sensor, return air sensor, dirty filter 
indicator switch, and air proving switch.

JOHNSON CONTROLS BAS CONTROL - 

The Johnson 

Control YK-UNT-1126 building automation system con-
troller is factory installed. Includes supply air sensor, 
return air sensor, dirty filter indicator switch, and air prov-
ing switch.

CPC BAS CONTROL - 

The Computer Process Controls 

Model 810-3060 ARTC Advanced Rooftop building auto-
mation system controller is factory installed. Includes 
supply air sensor, return air sensor, dirty filter indicator 
switch and air proving switch.

HONEYWELL BAS CONTROL -

 The Honeywell 

W7750C building automation system controller is factory 
installed. Includes air supply sensor, return air sensor, 
dirty filter indicator switch, and air proving switch.

SMOKE DETECTORS

 - (supply air & return air) The 

smoke detectors stop operation of the unit by interrupting 
power to the control board if smoke is detected within the 
air compartment.

COIL GUARD

 - Customers can purchase a coil guard kit 

to protect the condenser coil from damage. This is not a 
hail guard kit.

STAINLESS STEEL HEAT EXCHANGER

 - For applica-

tions in corrosive environments, this option provides a 
full stainless steel heat exchanger assembly.

STAINLESS STEEL DRAIN PAN - 

An optional rust-

proof stainless steel drain pan is available to provide 
years of trouble-free operation in corrosive environ-
ments.

BOTTOM DRAIN CONNECTION -

 An optional bottom 

drain connection is available for inside the curb connec-
tions for applications in cold environments to reduce 
freezing drain lines.

PHASE MONITORS

 - Designed to prevent unit damage. 

The phase monitor will shut the unit down in an out-of-
phase condition.

DIRTY FILTER SWITCH

 - This kit includes a differential 

pressure switch that energizes the fault light on the unit 
thermostat, indicating that there is an abnormally high 
pressure drop across the filters. Factory installed option 
or field installed accessory.

HINGED FILTER DOOR/“TOOLLESS” BLOWER AND 
ACCESS PANELS 

(not hinged) - This option allows for 

easy access and maintenance.

NOTE:

Knobs are shipped inside the unit to prevent ship-
ping damage. These must be field installed for 
tool-less operation.

Factory installed Smoke Detectors in the return air,
may be subjected to freezing temperatures during
“off” times due to outside air infiltration. These
smoke detectors have an operational limit of 32°F
to 131°F. Smoke detectors installed in areas that
could be outside those limitations will have to be
moved to prevent having false alarms.

Summary of Contents for CSA 48

Page 1: ...or frame All units include Powder Paint finish that meets ASTM B 117 1000 hour salt spray standards Permanently lubricated motors Bottom or side air discharge configuration capability field convertibl...

Page 2: ...6 DH048 COOLING CAPACITIES 4 TON 10 7 DH060 COOLING CAPACITIES 5 TON 11 8 SUPPLY AIR BLOWER PERFORMANCE 3 TON BELT DRIVE SIDE DUCT APPLICATION 12 9 SUPPLY AIR BLOWER PERFORMANCE 4 TON BELT DRIVE SIDE...

Page 3: ...1 4 5 W Options 1 3 4 5 X Options 3 5 Y Options 4 5 Z Options 3 4 5 1 Disconnect 2 Non Pwr d Conv Outlet 3 Smoke Detector S A 4 Smoke Detector R A 5 Pwr d Conv Outlet Options SS Drain Pan Configurati...

Page 4: ...n their configuration of cooling and heat Safety Monitoring The control board monitors the high and low pressure switches the freezestats the gas valve if applicable and the temperature limit switch o...

Page 5: ...LIC COATED EVAPORATOR AND CON DENSER COILS Special coating process that utilizes Technicoat 10 1TM processes Coating is applied by total immersion of the complete coil for maximum protection ELECTRIC...

Page 6: ...C BAS CONTROL The Computer Process Controls Model 810 3060 ARTC Advanced Rooftop building auto mation system controller is factory installed Includes supply air sensor return air sensor dirty filter i...

Page 7: ...propane HIGH ALTITUDE PROPANE Burner orifices and pilot orifices are provided for proper furnace operation at alti tudes up to 6 000 feet This accessory supplements the basic propane conversion kit LO...

Page 8: ...2 CAPACITY RATINGS ARI 210 240 1 1 80 67 F Indoor and 95 F outdoor MODEL MBH EER2 2 EER Energy Efficiency Ratio at full load the cooling capacity in Btu s per hour Btuh divided by the power input in...

Page 9: ...9 5 34 9 3 73 34 9 34 9 34 9 30 5 26 0 21 5 17 0 72 46 5 3 62 29 7 25 8 21 8 17 8 13 8 42 9 3 83 28 0 24 0 20 0 16 0 12 0 67 41 6 3 53 36 0 32 0 28 0 24 0 20 1 16 1 12 1 38 6 3 74 34 8 30 8 26 8 22 8...

Page 10: ...34 29 24 19 62 39 3 6 39 39 40 35 30 25 20 35 3 9 35 35 37 32 27 22 57 38 3 6 38 38 38 33 28 23 18 34 3 8 34 34 34 29 24 19 72 49 3 8 35 31 26 21 17 45 4 1 33 29 24 20 15 67 44 3 7 43 39 34 30 25 20 1...

Page 11: ...1 53 50 44 38 32 26 20 62 55 4 7 55 55 54 48 42 36 30 49 5 0 49 49 49 43 37 31 25 57 54 4 7 54 54 53 47 41 35 29 49 5 0 49 49 49 43 37 31 25 72 65 4 9 44 39 33 28 23 60 5 2 42 36 31 26 20 67 57 4 8 5...

Page 12: ...TIC RESISTANCE Table for resistance values on applications other than gas electric units with side duct airflows TABLE 9 SUPPLY AIR BLOWER PERFORMANCE 4 TON BELT DRIVE SIDE DUCT APPLICATION RPM WATTS...

Page 13: ...t 230 460 Volts with side duct connections 2 Includes allowances for a wet evaporator coil 1 filters and the heat exchangers Refer to STATIC RESISTANCE Table for resistance values on applications othe...

Page 14: ...06 0 07 0 08 0 09 0 11 0 13 0 15 0 17 0 20 0 23 0 26 0 06 0 07 0 08 0 09 0 10 0 11 0 12 0 14 0 16 0 19 0 22 0 08 0 10 0 12 0 14 0 16 0 18 0 20 0 23 0 26 0 29 0 32 COOLING ONLY2 RESISTANCE IWG CFM DES...

Page 15: ...3 40 2CE045107252 5 6 15 5 32 7 40 2CE04511025 8 0 22 2 41 0 45 2CE04511525 11 9 33 0 54 5 60 2CE04512025 15 9 44 1 68 4 70 230 3 60 13 1 110 0 2 3 10 6 0 0 None 29 3 40 2CE045105252 5 3 12 7 29 3 40...

Page 16: ...6 25 5 38 4 40 2CE04511525 15 9 38 2 54 3 60 2CE04512025 21 2 51 0 70 2 80 460 3 60 6 7 54 0 1 3 2 6 0 0 None 12 3 15 2CE045107462 6 8 8 2 13 5 15 2CE045110462 10 1 12 1 18 4 20 2CE045115462 13 6 16 4...

Page 17: ...50 2CE045107252 5 6 15 5 45 2 50 2CE04511025 8 0 22 2 53 5 60 2CE04511525 11 9 33 0 67 0 70 2CE04512025 15 9 44 1 80 9 90 230 3 60 13 1 110 0 2 3 10 6 10 0 None 39 3 50 2CE045105252 5 3 12 7 41 7 50...

Page 18: ...25 5 50 9 60 2CE04511525 15 9 38 2 66 8 70 2CE04512025 21 2 51 0 82 7 90 460 3 60 6 7 54 0 1 3 2 6 5 0 None 17 3 20 2CE045107462 6 8 8 2 19 7 20 2CE045110462 10 1 12 1 24 7 25 2CE045115462 13 6 16 4 2...

Page 19: ...CONDENSER COILS Rows Deep 2 2 2 Fins Per Inch 18 18 18 Face Area Sq Ft 17 1 17 1 17 1 COMPRESSOR Qty Per Unit Recip Type 1 1 1 AIR FILTERS Quantity Per Unit 15 X 20 X 1 or 2 2 2 2 Quantity Per Unit 1...

Page 20: ...BACK POSITION COOLING HEATING ELECTRONIC THERMOSTAT MULTI STAGE RH RC Y W G R Y1 W1 C G ADD JUMPER THERMOSTAT1 TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER 1ELECTRONIC PROGRAMMABLE THERMOSTA...

Page 21: ...254597 YTG B 0507 Unitary Products Group 21 FIGURE 3 UNIT DIMENSIONS 3 5 TON COOLING ONLY ELECTRIC HEAT FRONT VIEW FIGURE 4 UNIT DIMENSIONS 3 5 TON COOLING GAS HEAT FRONT VIEW...

Page 22: ...254597 YTG B 0507 22 Unitary Products Group FIGURE 5 UNIT WITH ECONOMIZER RAINHOOD FIGURE 6 UNIT WITH FIXED OUTDOOR AIR MOTORIZED DAMPER RAINHOOD DETAIL A DETAIL B...

Page 23: ...RY See Detail B MOUNTING BRACKET FOR DICONNECT SWITCH Shipped attached to the blower housing inside the blower compartment FIELD SUPPLIED DISCONNECT SWITCH LOCATION BLOWER MOTOR ACCESS FILTER ACCESS D...

Page 24: ...254597 YTG B 0507 24 Unitary Products Group FIGURE 9 TYPICAL APPLICATIONS...

Page 25: ...82 104 105 107 DH036N04 605 134 132 168 171 90 89 88 112 113 114 DH036D06 615 137 134 171 174 91 90 89 113 115 116 DH036N08 625 139 136 173 177 93 92 91 115 117 118 DH036D10 635 141 138 176 179 94 93...

Page 26: ...DH Cooling Only 565 610 645 DH Gas Electric N04 605 N06 660 N08 625 705 N10 680 715 D06 615 660 695 D10 635 680 715 OPTIONS Economizer 50 26 18 23 28 92 10 5 Motorized Damper Electric Heater 5 7 kW 10...

Page 27: ...ped charged with R 22 refrigerant and factory tested prior to shipment All unit wiring shall be both numbered and color coded All units the cooling performance shall be rated in accordance with DOE an...

Page 28: ...ge logic energy saving direct spark ignition and redun dant main gas valve Venter wheel shall be constructed of stainless steel for corrosion resistance The heat exchanger shall be of the tubular type...

Page 29: ...5 IWG A unit mounted potentiome ter shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space duri...