246814-YTG-D-0606
Unitary Products Group
13
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
AY024MA321
INDOOR COIL MODEL NO.
G2FD030S17
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
21.4
24.0
23.7
25.8
28.6
23.5
24.7
24.2
26.2
28.6
25.5
25.3
24.8
26.5
28.7
S.C.
20.6
19.1
16.1
16.3
13.0
22.7
21.8
18.6
18.3
14.3
24.7
24.5
21.0
20.4
15.6
KW
1.6
1.6
1.6
1.6
1.5
1.6
1.5
1.6
1.5
1.5
1.5
1.5
1.6
1.5
1.5
75
T.C.
20.9
23.0
22.6
25.0
27.5
22.6
23.6
23.2
25.2
27.5
24.4
24.2
23.8
25.4
27.4
S.C.
20.1
18.6
15.6
15.9
12.7
21.9
21.0
18.0
17.9
13.9
23.6
23.4
20.4
20.0
15.2
KW
1.8
1.7
1.8
1.7
1.7
1.7
1.7
1.8
1.7
1.7
1.7
1.7
1.7
1.7
1.7
85
T.C.
20.3
21.9
21.6
24.2
26.4
21.8
22.5
22.2
24.3
26.3
23.2
23.0
22.7
24.4
26.2
S.C.
19.7
18.1
15.1
15.4
12.4
21.1
20.2
17.5
17.5
13.6
22.5
22.3
19.8
19.6
14.8
KW
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
95
T.C.
19.7
20.9
20.6
23.4
25.4
20.9
21.4
21.1
23.4
25.2
22.1
21.9
21.7
23.4
25.0
S.C.
19.2
17.6
14.6
15.0
12.1
20.3
19.4
16.9
17.1
13.2
21.4
21.2
19.2
19.2
14.3
KW
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
105
T.C.
18.9
19.8
19.4
22.1
24.1
19.8
20.3
19.9
22.1
23.9
20.8
20.8
20.4
22.0
23.6
S.C.
18.3
17.0
14.1
14.5
11.6
19.2
18.6
16.3
16.6
12.8
20.2
20.1
18.5
18.7
13.9
KW
2.3
2.3
2.3
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
115
T.C.
18.0
18.8
18.3
20.9
22.9
18.8
19.2
18.7
20.8
22.6
19.6
19.7
19.1
20.8
22.3
S.C.
17.5
16.5
13.6
14.1
11.2
18.2
17.8
15.7
16.1
12.3
18.9
19.1
17.8
18.2
13.5
KW
2.5
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
125
T.C.
17.1
17.7
17.3
19.6
21.7
17.7
18.2
17.5
19.5
21.3
18.3
18.6
17.8
19.5
21.0
S.C.
16.6
16.0
13.0
13.6
10.8
17.2
17.0
15.0
15.6
11.9
17.7
18.1
17.0
17.7
13.1
KW
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.9
2.8
2.8
2.8
2.8
2.9
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MV12B
FC/MC24B
1.03
1.04
0.94
MV12B
FC/MC30B
1.03
1.04
0.94
MV12B
FC/MC36B
1.03
1.04
0.94
MV12B
G4FD030H17T2A
1.03
1.04
0.94
MV12B
G4FD036H17T2A
1.03
1.04
0.94
MV16C
FC/MC36C
1.03
1.04
0.94
AHP24
—
1.00
1.00
1.00
F4FP030H06T2A
—
1.00
1.00
1.00
—
FC/MC/PC24
1.00
1.00
1.00
—
FC/MC/PC30
1.00
1.00
1.00
—
FC/MC/PC36
1.00
1.00
1.00
—
G4FA036S17T2A
1.00
1.00
1.00
—
G4FA036S21T2A
1.00
1.00
1.00
—
G4FD030H17T2A
1.00
1.00
1.00
—
G4FD035H14T2A
1.00
1.00
1.00
—
G4FD036H17T2A
1.00
1.00
1.00
—
HC30
1.00
1.00
1.00
—
UC24
1.00
1.00
1.00
—
UC30
1.00
1.00
1.00
—
UC36
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC24A
1.02
1.02
0.97
PV9*A12
FC/MC/PC24A
1.02
1.02
0.97
PV8*B16
FC/MC/PC24B
1.02
1.02
0.97
PV9*B12
FC/MC/PC24B
1.02
1.02
0.97
PV8*A12
FC/MC/PC30A
1.02
1.02
0.97
PV9*A12
FC/MC/PC30A
1.02
1.02
0.97
PV8*B16
FC/MC/PC30B
1.02
1.02
0.97
PV9*B12
FC/MC/PC30B
1.02
1.02
0.97
PV8*A12
FC/MC/PC36A
1.02
1.02
0.97
PV8*B16
FC/MC/PC36B
1.02
1.02
0.97
PV9*A12
FC/MC/PC36A
1.02
1.02
0.97
PV9*B12
FC/MC/PC36B
1.02
1.02
0.97
PV8*B16
G4FA036S17T2A
1.01
1.01
0.96
PV9*B12
G4FA036S17T2A
1.02
1.02
0.97
PV8*B16
G4FD030H17T2A
1.01
1.01
0.96
PV9*B12
G4FD030H17T2A
1.01
1.01
0.96
PV8*A12
G4FD035H14T2A
1.01
1.01
0.96
PV9*A12
G4FD035H14T2A
1.01
1.01
0.96
PV8*B16
G4FD036H17T2A
1.02
1.02
0.97
PV9*B12
G4FD036H17T2A
1.02
1.02
0.97
PV8*A12
HC30
1.02
1.02
0.97
PV9*A12
HC30
1.02
1.02
0.97