246814-YTG-D-0606
2
Unitary Products Group
1. Dual element fuses or HACR circuit breaker.
2. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15
feet, add or
subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without
notice. certified dimensions will be provided upon request.
1. Including Fan Guard
PHYSICAL AND ELECTRICAL DATA
MODEL
AY012MA321
AY018MA321
AY024MA321
AY030MA321
AY036MA321
Unit Supply Voltage
208 - 230V, 1 Phase, 60Hz
Minimum Circuit Ampacity
8.9
9.5
12.0
14.5
18.2
Maximum Overprotection Device
1
15
15
20
25
30
Rated Load Amps
6.7
7.2
8.9
11
13.5
Compressor
Model
2K20S236T6A 2K22S236SUB 2J29S236A1A
2J35S236B1A H21J30BABCA
Brand
Panasonic
Panasonic
Panasonic
Panasonic
Bristol
Type
Rotary
Rotary
Rotary
Rotary
Recip
LRA
33.0
40.0
60.0
68.0
78.0
Start Kit
Yes
Yes
Yes
Yes
No
CCH
No
No
No
No
No
Dimensions
Length (in)
21-3/4
21-3/4
21-3/4
21-3/4
21-3/4
Width (in)
21-3/4
21-3/4
21-3/4
21-3/4
21-3/4
Height (in)
22-1/2
22-1/2
24-1/4
26-3/4
30-3/4
Weight (lbs)
85
90
105
110
140
Fan & Motor
HP
1/12
1/12
1/8
1/8
1/4
RPM
1100
1100
1075
1075
1100
FLA
0.5
0.5
0.8
0.8
1.4
CFM
1450
1450
1700
1800
2150
Dia (in)
17-1/2
17-1/2
17-1/2
17-1/2
17-1/2
OD Coil
Area (ft^2)
7.26
7.26
7.89
8.77
10.17
Rows
1
1
1
1
1
Fins / Inch
23
23
23
23
23
Connection OD
Liquid (in)
3/8
3/8
3/8
3/8
3/8
Suction (in)
3/4
3/4
3/4
3/4
3/4
Line Set OD
Liquid (in)
3/8
3/8
3/8
3/8
3/8
Suction (in)
5/8
5/8
5/8
3/4
3/4
Refrigerant
R-22
R-22
R-22
R-22
R-22
Unit Charge (lbs - oz)
2
2 - 14
2 - 14
3 - 6
3 - 14
3 - 8
Charge Per Foot - oz
0.66
0.66
0.66
0.68
0.68
A
C
B
Unit
Model
Weight
(Lbs.)
Dimensions (Inches)
Refrigerant
Connection
Service Valve Size
A
1
B
C
Liquid
Vapor
012
85
22-1/2
21-3/4
21-3/4
3/8”
3/4”
018
90
22-1/2
21-3/4
21-3/4
024
105
24-1/4
21-3/4
21-3/4
030
110
26-3/4
21-3/4
21-3/4
036
140
30-3/4
21-3/4