background image

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TECHNICAL GUIDE

SPLIT-SYSTEM
AIR CONDITIONERS

10 SEER

AM012M102 THRU AM030M1021
(1 THRU 2.5 NOMINAL TONS, 1 PH)

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at

www.ariprimenet.org.

®  

LISTED

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

Certification applies only

when the complete

system is listed

with ARI.

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

HT

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

NI

N O

I

TI

D

N

O

R

I

A

036-21573-001 Rev. A (0304)

DESCRIPTION

The 10 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, each designed to serve a specific function. Match-
ing air handlers are available for upflow, downflow, or hori-
zontal applications to provide a complete system. Electric
heaters are available if required. Add-on coils are available
for use with upflow, downflow, or horizontal furnaces and air
handlers.

WARRANTY

5-year limited parts warranty.

5-year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS - 

The coil is constructed

of enhanced copper tube and aluminum fins.

COIL PROTECTION -

 Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR - 

Recip compressors are

internally protected against high pressure and tempera-
ture. This is accomplished by the simultaneous operation
of high pressure relief valve and a temperature sensor
which protects the compressor if undesirable operating
conditions occur. A liquid line filter-drier further protects the
compressor.

DURABLE FINISH - 

The cabinet is made of pre-painted

steel. The pre-treated flat galvanized steel provides a bet-
ter paint-to-steel bond, which resists corrosion and rust
creep. Special primer formulas and matted desert sand fin-
ish insure less fading when exposed to sunlight.

LOWER INSTALLED COST - 

Installation time and costs

are reduced by easy power and control wiring connec-
tions. The unit contains enough refrigerant for matching
indoor coils and 15 feet of interconnecting piping. The
small base dimension means less space is required on the
ground or roof.

TOP DISCHARGE - 

The warm air from the top mounted

fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.

LOW OPERATING SOUND LEVEL - 

The upward air flow

carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.

LOW MAINTENANCE - 

Long life permanently lubricated

motor-bearings need no annual servicing.

EASY SERVICE ACCESS - 

Fully exposed refrigerant con-

nections and a single panel covering the electrical controls
make for easy servicing of the unit.

SECURED SERVICE VALVES - 

Secured re-usable ser-

vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.

U.L. AND C.U.L. LISTED -

 Approved for outdoor applica-

tion.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.

Summary of Contents for AM012M1021

Page 1: ...essors are internally protected against high pressure and tempera ture This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the comp...

Page 2: ...1 100 1 075 1 075 Nominal CFM 1 600 1 550 1 750 1 750 Coil Face Area Sq Ft 7 22 7 22 7 22 7 94 Rows Deep 1 1 1 1 Fins Inch 14 16 20 20 Liquid Line OD 3 8 3 8 3 8 3 8 Vapor Line OD 5 8 5 8 5 8 3 4 Uni...

Page 3: ...3 51 1 F2RP F2FP024 61 51 7 59 2 F2RP F2FP030 65 63 2 F2RP F2FP036 75 63 8 MDD30BSD 57 59 2 MDD30MSD 63 63 2 FOOTNOTES 1 These orifices are packed in the customer packet of each outdoor unit 2 These...

Page 4: ...18 6 13 4 10 00 9 50 AM024M1021 N1AHB0806 10 17 G2FD024 S H 17 850 23 4 16 8 10 00 9 15 AM030M1021 N1AHB1206 10 15 18 17 G2FD030 S H 17 1050 28 2 20 3 10 00 9 00 1 PH 10 SEER AC F2RP 4 5 AM012M1021 F2...

Page 5: ...20 14 17 G1UA024S14 17 850 23 0 16 6 10 00 9 05 14 G1UA036S14 850 23 8 17 2 10 00 9 25 14 17 G2FD024 S H 14 17 850 23 4 16 8 10 00 9 15 AM030M1021 925 1175 14 G1FA030S14 1050 28 2 20 2 10 00 8 95 14 G...

Page 6: ...TH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL NOTE ALL OUTDOOR WIRING MUST BE WEATHERPROOF ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE NEC AND OR LOCAL CODES POWER WIRING 208 230...

Page 7: ...14 6 13 6 S C 9 8 9 5 9 0 10 1 10 0 9 5 10 5 10 4 10 1 K W 1 32 1 31 1 31 1 34 1 33 1 33 1 36 1 35 1 35 95 T C 15 1 13 8 12 4 15 2 14 1 12 7 15 3 14 4 13 0 S C 9 9 9 5 8 8 10 3 10 0 9 3 10 7 10 5 9 9...

Page 8: ...11 8 13 4 13 5 13 2 K W 1 70 1 68 1 66 1 77 1 75 1 73 1 84 1 82 1 80 95 T C 18 9 17 3 15 2 19 1 17 7 15 9 19 4 18 0 16 5 S C 11 3 10 8 9 9 12 6 12 4 11 5 14 0 13 9 13 0 K W 1 81 1 79 1 76 1 88 1 86 1...

Page 9: ...8 2 43 2 38 2 57 2 53 2 47 95 T C 25 1 22 8 21 0 25 5 23 6 21 5 25 9 24 4 21 9 S C 15 2 14 4 13 1 17 1 16 5 15 2 19 0 18 6 17 2 K W 2 53 2 46 2 39 2 63 2 57 2 50 2 72 2 68 2 60 105 T C 23 1 20 7 18 5...

Page 10: ...3 95 T C 29 9 27 7 25 3 30 6 28 4 26 0 31 2 29 0 26 7 S C 18 9 18 5 18 0 20 4 19 9 19 4 21 9 21 3 20 7 K W 3 14 3 06 2 98 3 24 3 16 3 09 3 35 3 27 3 20 105 T C 27 9 25 6 22 9 28 6 26 2 23 6 29 3 26 9...

Page 11: ...ION UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE A...

Page 12: ...to change without notice Printed in U S A 036 21573 001 Rev A 0304 Copyright by York International Corp 2004 All rights reserved Supersedes Nothing Unitary 5005 Norman Product York OK Group Drive 7306...