background image

Remote controller
is not available.

Is the remote controller out of effective distance to the indoor unit?

Are there any obstructions between the controller and the

signal receptor?

Is the battery exhausted?

Indoor unit does not operate
immediately when the air
conditioner is restarted.

There is unusual smell
blowing from the outlet
after operation is started.

Cooling (Heating)
efficiency is not
good.

Is the setting temperature suitable?

Are air filter dirty?

Is the air inlet or outlet obstructed?
Is indoor fan speed set at low speed?

Is there any heat source in your room?

Air conditioner can
not operate at all.

Has the power been shut down?

Is the wiring loose?

Is voltage too high or too low ?(measured by professionals)

Does it reach the set time for start up?

Does the circuit protection device trip?

If the air conditioner is turned on immediately after it is
turned off, the protective delay switch will delay the
operation for 3 to 5 minutes.

The air conditioner itself does not have undesirable
odor. If there is odor, it may be due to accumulation
of the odor in the environment. Please clean the air
filter or activate the cleaning function.

There is sound of running
water during the running
of air conditioner.

Sometimes the "hissing" sound of running water
can be heard. This is the sound of the flow of the
refrigerant, not a malfunction.

A slight "click" sound is
heard at the of start-up or
shut-down.

Due to temperature changes, panel and other parts

will swell, causing the sound of friction. This is normal,

not a fault.

During the cooling operation,
the indoor unit outlet
sometimes will blow out mist.

This is because the indoor air is cooled rapidly. After it
runs for some time, the indoor temperature and
humidity will be reduced and the mist will disappear.

Shrill sound is heard or Unpleasant odor is emitted during the operation.

.

There is an abnormal heat in power supply cord and power plug

Accidentally pour impurities or water into the machine or the remote control.

Air switch or protection switch often breaks.

Immediately stop all operations and cut off the power supply ,
contact our Service center locally in following situations.

Troubleshooting

Phenomenon

Troubleshooting

- 11 -

Summary of Contents for Altair Series

Page 1: ...HIGH WALL INVERTER Form UHKEALTAIR 171219 New Released User s Manual ALTAIR HIGH WALL INVERTER R 410A 60Hz 16SEER Issue Date Dec 19 2017...

Page 2: ...fter installation and test operation 1 6 8 10 12 15 16 19 Installation service 9 CONTENTS Operation and maintenance Safety Precautions Notices for use Names of each part Clean and care Troubleshooting...

Page 3: ...ence and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Clean...

Page 4: ...the indoor unit watered or being too wet Otherwise it may cause short circuit NO Don t pull the power cable The damage of pulling power cord will cause serious electric shock NO Don t share the socke...

Page 5: ...be cut in time to prevent the occurrence of danger The appliance shall be installed in accordance with national wiring regulations An earth leakage breaker with rated capacity must be installed to av...

Page 6: ...pliance for disposals at least free of charge Meaning of crossed out wheeled dustbin 4 The specification of the fuse are printed on the circuit board such as 3 15A 250V AC etc Refrigerant leakage cont...

Page 7: ...plug an all pole switch must be installed in the fixed wiring and the distance between contacts should be no less than 3 0 mm The power supply circuit should have leakage protector and air switch of w...

Page 8: ...fan of the indoor unit will not start running immediately after the heating is started to avoid blowing out cool air When it is cold and wet outside the outdoor unit will develop frost over the heat...

Page 9: ...Force switch 1 Use up down swing and left right swing buttons on the remote controller to adjust the airflow direction Refer to the operation manual of the remote controller for detail 2 For models wi...

Page 10: ...his manual are just schematic diagrams the actual is the standard Plug WIFI function Negative ion function and Vertical and horizontal swing function both are optional the actual unit shall prevail AU...

Page 11: ...ter under any circumstances Volatile liquids such as thinner or gasoline will damage the air conditioner housing therefore please clean the housing of air conditioner only with soft dry cloth and damp...

Page 12: ...wrong maintenance may cause electric shock or fire please contact the authorized service center and let the professionals conduct the maintenance and checking the following items prior to contacting...

Page 13: ...ble odor If there is odor it may be due to accumulation of the odor in the environment Please clean the air filter or activate the cleaning function There is sound of running water during the running...

Page 14: ...within the reach of children Shorten the connection between the indoor and outdoor units Select where it is easy to perform service and repair and where the ventilation good The outdoor unit shall no...

Page 15: ...for connection Cable Types Outdoor Power Cable H07RN F or H05RN F H07RN F or H05RN F Interconnection cord Minimum Cross Sectional Area of Power Cable and Interconnection cord Notices for installation...

Page 16: ...e a reliable grounding Do not connect the grounding wire to a gas pipe water pipe lightning rod telephone line or a circuit poorly grounded to the earth The grounding wire is specially designed and sh...

Page 17: ...t Name 1 Indoor Unit Set Quantity 2 Remote Controller Batteries 7 PC PC 1 Instructions Outdoor Unit Connecting pipe 6 4500 Packing list 1 Name ROLL Unit PC 1 1 1 Set Quantity PC 1 1 Unit PACKET Set Pa...

Page 18: ...revent vibration 2 Use the type screw to fasten the peg board horizontally mount the peg board on the wall and ensure the lateral horizontal and longitudinal vertical 3 Pull the peg board by hand afte...

Page 19: ...2 Connect the connecting pipe to the indoor unit Aim at the pipe center tighten the nut with fingers and then tighten the Taper Taper nut with a torque wrench and the direction is shown in diagram on...

Page 20: ...nterconnection cord unit is connected in the factory there is no need of connection If the is not provided connection is needed in accordance with interconnection cord the wiring diagram Constant spee...

Page 21: ...he connection pipe When prolonging the piping extra amount of refrigerant must be added so that the operation and performance of the air conditioner will not be compromised Not needed 5M Piping length...

Page 22: ...k in its original place and fasten it with screws E parts cover 1 2 L N Wiring Connection Outdoor unit installation 20 5 3 N 2 4 1 To power L N To Indoor unit To power To Indoor unit S N Lo L To power...

Page 23: ...ose manifold valve and vacuum pump 3 Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes and check that the compound vacuum gauge reads 0 1MPa 76cmHg 4 After applyi...

Page 24: ...wires 3 If the grounding wire of the air conditioner is securely grounded Installation Safety Check 1 If the installation is secure 2 If the water drain is smooth 3 If the wiring and piping are corre...

Page 25: ...2017 Johnson Controls Inc www johnsoncontrols com Form UHKEALTAIR 171219 Johnson Controls reserve the right to change product features without prior notice...

Reviews: