1. Make a hole with an electric hammer or a
water drill at the predetermined position on
the wall for piping, which shall slant outwardly
by 5°-10°.
2. To protect the piping and the cables from
being damaged running through the wall,
and from the rodents that may inhabit in
the hollow wall, a pipe protecting ring shall
be installed and sealed with putty.
1. The wall for installation of the indoor unit shall
be hard and firm, so as to prevent vibration.
2. Use the "+" type screw to fasten the peg board,
horizontally mount the peg board on the wall, and
ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation,
to confirm whether it is solid.
Space to the ceiling
Space to the wall
20cm above
Mounting plate
Wall-through Hole
15cm above
200cm above
Space to the floor
Pipe protection ring
Putty
Dimension drawing of indoor unit installation
Space to the wall
20cm above
Note: Usually, the wall hole is Φ60mm~Φ80mm.
Avoid pre-buried power wire and hard wall
when making the hole.
- 16 -
Indoor unit installation
Outside
Wall
Inside