Electrical Safety Requirements
●
Be sure to use the rated voltage and air conditioners dedicated
circuit for the power supply, and the power cord diameter must
meet the national requirements.
When the maximum current of air conditioner is
16A, it must use
●
≥
the air switch or leakage protection switch equipped with
protection devices.
The normal operating range is 90%-110% of the local rated voltage.
●
The minimum clearance between the air conditioner and the
●
combustibles is 1.5 m.
The
enables connect the indoor and outdoor
●
interconnection cord
units. You must first choose the right cable size before preparing it
for connection.
Cable Types:
●
Outdoor Power Cable: H07RN-F or H05RN-F;
: H07RN-F or H05RN-F;
Interconnection cord
Minimum Cross-Sectional Area of Power Cable and
●
Interconnection cord
Notices for installation
- 13 -
Rated Current
of Appliance(A)
Nominal Cross-
Sectional Area(mm )
2
>
≤
6 and
10
>
≤
10 and
16
>
≤
16 and
25
>
≤
25 and
32
>
≤
32 and
40
0 75
.
1
1 5
.
2 5
.
4
6
Appliance
Amps(A)
AWG
10
13
18
25
30
18
16
14
12
10
North America
Other Regions
●
The size of the
, power cable, fuse, and
interconnection cord
switch needed is determined by the maximum current of the unit.
The maximum current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate to choose the
right cable, fuse, or switch.
Note: Core number of cable refer to the detailed wiring diagram
●
adhered on the unit which you purchased.
40
8
>
≤
3 and
6