TABLE 2: 

Field Installed Accessories - Non Electrical

MODEL NO.

DESCRIPTION

USED WITH

1NP0347

PROPANE (LP) CONVERSION KIT

ALL MODELS

1PS0313

HIGH ALTITUDE PRESSURE SWITCH KIT 

(DOES NOT INCLUDE ORIFICES)

57, 80, 100 

MBH

1PS0314

120 

MBH

1SR0302

SIDE RETURN FILTER KIT 1” FILTER

ALL MODELS

1SR0200

SIDE RETURN FILTER KIT 1-4” FILTER

ALL MODELS

1BR0114

BOTTOM RETURN FILTER KIT 1” FILTER

14-1/2” CABINETS

1BR0214

BOTTOM RETURN FILTER KIT 1-4” FILTER

14-1/2” CABINETS

1BR0117

BOTTOM RETURN FILTER KIT 1” FILTER

17-1/2” CABINETS

1BR0217

BOTTOM RETURN FILTER KIT 1-4” FILTER

17-1/2” CABINETS

1BR0121

BOTTOM RETURN FILTER KIT 1” FILTER

21” CABINETS

1BR0221

BOTTOM RETURN FILTER KIT 1-4” FILTER

21” CABINETS

1BR0124

BOTTOM RETURN FILTER KIT 1” FILTER

24-1/2” CABINETS

1BR0224

BOTTOM RETURN FILTER KIT 1-4” FILTER

24-1/2” CABINETS

1HF0801

INTERNAL FILTER KIT WITH 1” FIBER FILTER

ALL MODELS

REPLACEMENT PART CONTACT INFORMATION

This is a generic parts list. To request a complete parts list, refer to the contact information below:

• Visit our website at www.source1parts.com for the following information:

1. Search for a part or browse the catalog.

2. Find a dealer or distributor.

3. Customer Service contact information.

a. Click on the “Brand Links” button

b. Click on the “Customer Service” button

• You can contact us by mail. Just send a written request to:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

Summary of Contents for AHV8 UH Series

Page 1: ...t or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or prop erty damage Do not store or use gasoline or other f...

Page 2: ...he ducts ter minate outside the space containing the furnace 4 Examine the furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure...

Page 3: ...s 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove burner door 5 Move gas control switch to the OFF position...

Page 4: ...with cleanable filter s at this time Cleanable filter s may be cleaned as described in the manufacturer instructions or as described below and then re installed To replace the filter after cleaning y...

Page 5: ...et Remove this screw before proceeding 3 Unplug the vent motor wires and ground wire Remove the pres sure switch tubing at the tap on the vent motor housing NOTE It is recommended that replacement gas...

Page 6: ...e Y2 circuit for high cooling CONTROL BOARD Variable speed motors will adjust the motor speed in order to maintain the indoor fan CFM The control board is used to control the blower speed thus the CFM...

Page 7: ...higher speed will take 30 seconds and any ramp down to a lower speed or off will take 60 seconds Tap D is the normal profile best suited for most of the country where neither excessive humidity nor ex...

Page 8: ...out Low gas pressure faulty gas valve faulty hot surface ignitor or burner problem may cause this The furnace will lock out for one hour and then restart 8 RED FLASHES This fault is indicated if the f...

Page 9: ...DUCER LOW STAGE PRESSURE SWITCH HSI 1ST STAGE MAIN VALVE FLAME SENSE LOW CIRCULATOR HEAT SPEED 1ST STAGE LOW PRESSURE SWITCH CLOSE RECOGNITION HSI WARM UP 17 SEC IGNITION ACTIVATION PERIOD 4 SEC TRIAL...

Page 10: ...271002 UUM A 0407 10 Unitary Products Group SECTION III REPLACEMENT PARTS LIST 39 29 38 43 21 25 35 31 27 23 22 20 24 30 44 26 53 42 28 18 2 4 11 6 9 5 17 16 12 7 8 3 12A 7 36 25 37 12 20 11...

Page 11: ...ITER 22 DECK BLOWER Rear 23 DECK FRONT 24 HEAT EXCHANGER ASS Y 25 MANIFOLD GAS 26 PANEL UPPER ACCESS Burner Magnet FABRICATED PARTS Continued 27 PAN BASE 28 PANEL BLOWER ACCESS Magnet 29 PANEL TOP 30...

Page 12: ...1BR0121 BOTTOM RETURN FILTER KIT 1 FILTER 21 CABINETS 1BR0221 BOTTOM RETURN FILTER KIT 1 4 FILTER 21 CABINETS 1BR0124 BOTTOM RETURN FILTER KIT 1 FILTER 24 1 2 CABINETS 1BR0224 BOTTOM RETURN FILTER KIT...

Page 13: ...271002 UUM A 0407 Unitary Products Group 13 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Page 14: ...271002 UUM A 0407 14 Unitary Products Group NOTES...

Page 15: ...271002 UUM A 0407 Unitary Products Group 15 NOTES...

Page 16: ...to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servicing...

Reviews: