14
Johnson Controls Unitary Products
505591-YTG-A-0909
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total
electric power input during the same period.
— = Not Applicable.
** Refer to Quick Selection Chart for specific furnace match-up.
18 SEER HP WITH AV/SV - VARIABLE SPEED
YZH02411(C)
AV*36 –
21
1 600
19.2 –
–
3.80
2 765 24.0 16.9 9.60 4.00
2 600 24.0 15.1 9.30 3.20
YZH03611(C)
AV*36 –
21
1 830
26.5 –
–
4.20
2 1270 36.0 26.6 9.60 4.20
2 830 36.0 24.4 9.30 4.20
AV/SV*48 –
24
1 910
27.0 –
–
4.60
2 1190
36.0
26.2
10.00
4.60
2 910 36.0 24.4 9.70 3.60
YZH04811(C)
AV/SV*48 –
24
1 1135
36.2 –
–
4.00
2 1610 48.0 32.4 9.80 4.00
2 1135 38.5 25.6 9.50 3.40
AV/SV*60 –
24
1 1085
36.0 –
–
4.00
2 1655 48.0 32.6 9.80 4.00
2 1085 39.0 25.8 9.50 3.40
YZH06011(C)
AV/SV*60 –
24
1 1145
43.0 –
–
3.60
2 1765 58.0 39.4 9.30 3.80
2 1145 46.5 27.2 9.00
3.00
18 SEER HP WITH AHX
YZH02411(C)
AHX36
–
21
1
505
18.1
–
–
3.52
2
820
23.0
19.3
9.00
3.80
2
505
22.2
19.0
8.50
3.00
YZH03611(C)
AHX36
–
21
1
770
26.4
–
–
4.06
2
1225
35.8
26.6
9.60
4.20
2
770
35.4
25.2
9.30
3.20
AHX48
–
24
1
885
27.0
–
–
4.32
2
1255
36.0
26.4
10.00
4.60
2
885
36.1
24.9
9.70
3.60
YZH04811(C)
AHX48
–
24
1
1070
36.2
–
–
3.76
2
1660
48.0
32.6
9.80
4.00
2
1070
38.0
32.3
9.50
3.40
AHX60
–
24
1
1075
36.0
–
–
3.76
2
1680
48.0
32.4
9.80
4.00
2
1075
38.3
32.1
9.50
3.20
YZH06011(C)
AHX60
–
24
1
1075
43.0
–
–
3.30
2
1905
57.0
39.5
9.30
3.80
2
1075
45.8
27.0
9.00
3.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
HEATING CAPACITY - With Air Handler (Continued)
UNIT MODEL
AIR HANDLER
MODEL
COIL
1
MODEL
W
ARI HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @ 47°
47° OD
17° OD