Johnson Controls Unitary Products
45
505591-YTG-A-0909
Multipliers for determining the performance with other indoor sections.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
Continued on next page.
HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
YZH03611(C)
INDOOR COIL MODEL NO.
FC/MC62D + MV12D
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1088
1188
1288
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
48.8 2.5 5.7 49.1 2.5 5.9 49.5 2.4 6.1
70
47.7 2.8 5.0 48.0 2.7 5.1 48.3 2.6 5.3
80
46.5 3.1 4.4 46.8 3.0 4.6 47.1 2.9 4.7
47
60
39.9 2.4 4.9 40.0 2.3 5.1 40.1 2.2 5.3
70
39.3 2.6 4.3 39.4 2.6 4.5 39.5 2.5 4.6
80
38.6 2.9 3.9 38.7 2.8 4.0 38.9 2.8 4.1
40
60
35.6 2.3 4.6 35.8 2.2 4.7 35.9 2.2 4.9
70
35.0 2.5 4.0 35.1 2.5 4.1 35.3 2.4 4.3
80
34.3 2.8 3.6 34.5 2.7 3.7 34.7 2.7 3.8
30
60
29.7 2.2 4.0 29.9 2.1 4.1 30.0 2.1 4.3
70
29.2 2.4 3.5 29.4 2.4 3.6 29.6 2.3 3.7
80
28.7 2.7 3.2 28.9 2.6 3.2 29.1 2.6 3.3
17
60
22.6 2.0 3.3 22.8 2.0 3.4 22.9 1.9 3.5
70
22.4 2.2 2.9 22.5 2.2 3.0 22.7 2.2 3.1
80
22.2 2.5 2.6 22.3 2.4 2.7 22.4 2.4 2.7
10
60
19.3 1.9 3.0 19.4 1.9 3.0 19.5 1.9 3.1
70
19.3 2.1 2.6 19.3 2.1 2.7 19.3 2.1 2.7
80
19.2 2.4 2.4 19.2 2.3 2.4 19.2 2.3 2.4
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
AHX36
–
0.97
0.97
0.94
AHX48
–
0.97
1.00
0.92
AV*36 –
1.00
0.98
1.02
AV/SV*48 –
1.00
1.00
1.00
MV16C FC/MC43C
1.00
1.00
1.00
MV16C FC/MC48C
1.00
1.00
1.00
MV12D FC/MC48D
1.00
1.00
1.00
MV12D FC/MC60D
1.00
1.00
1.00
MV12D
FC64D
0.99
1.01
0.98
–
FC64
1.00
0.95
1.05