TABLE 11: HEATING CAPACITIES - 3 TON (BHP036)

CFM

RETURN

AIR °F

CAP

1

& KW

OUTDOOR AIR TEMPERATURE, °F (72% RH)

-10

0

10

20

30

40

50

60

900

55

MBH

10.597

12.792

15.448

18.660

22.545

27.244

32.929

39.804

KW

1.791

1.898

2.005

2.112

2.219

2.326

2.433

2.540

70

MBH

9.420

11.615

14.271

17.483

21.368

26.067

31.752

38.627

KW

2.198

2.305

2.412

2.519

2.626

2.733

2.840

2.947

80

MBH

7.543

9.738

12.394

15.606

19.491

24.190

29.875

36.750

KW

2.476

2.583

2.690

2.797

2.904

3.011

3.118

3.225

1200

55

MBH

11.652

13.847

16.503

19.715

23.600

28.299

33.984

40.859

KW

1.825

1.932

2.039

2.146

2.253

2.360

2.467

2.574

70

MBH

10.475

12.670

15.326

18.538

22.423

27.122

32.807

39.682

KW

2.232

2.339

2.446

2.553

2.660

2.767

2.874

2.981

80

MBH

8.598

10.793

13.449

16.661

20.546

25.245

30.930

37.805

KW

2.510

2.617

2.724

2.831

2.938

3.045

3.152

3.259

1500

55

MBH

12.282

14.477

17.133

20.345

24.230

28.929

34.614

41.489

KW

1.779

1.886

1.993

2.100

2.207

2.314

2.421

2.528

70

MBH

11.105

13.300

15.956

19.168

23.053

27.752

33.437

40.312

KW

2.186

2.293

2.400

2.507

2.614

2.721

2.828

2.935

80

MBH

9.228

11.423

14.079

17.291

21.176

25.875

31.560

38.435

KW

2.464

2.571

2.678

2.785

2.892

2.999

3.106

3.213

1.

These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have 
been added.

TABLE 12: HEATING CAPACITIES - 3-1/2 TON (BHP042)

CFM

RETURN

AIR °F

CAP

1

& KW

OUTDOOR AIR TEMPERATURE, °F (72% RH)

-10

0

10

20

30

40

50

60

1050

55

MBH

15.404

17.988

20.968

24.404

28.369

32.941

38.215

44.298

KW

2.410

2.505

2.599

2.694

2.789

2.883

2.978

3.073

70

MBH

14.342

16.926

19.906

23.342

27.307

31.879

37.153

43.236

KW

2.835

2.930

3.024

3.119

3.214

3.308

3.403

3.498

80

MBH

13.669

16.253

19.233

22.669

26.634

31.206

36.480

42.563

KW

3.143

3.238

3.332

3.427

3.522

3.616

3.711

3.806

1400

55

MBH

17.901

20.485

23.465

26.901

30.866

35.438

40.712

46.795

KW

2.419

2.514

2.608

2.703

2.798

2.892

2.987

3.082

70

MBH

16.839

19.423

22.403

25.839

29.804

34.376

39.650

45.733

KW

2.844

2.939

3.033

3.128

3.223

3.317

3.412

3.507

80

MBH

16.166

18.750

21.730

25.166

29.131

33.703

38.977

45.060

KW

3.152

3.247

3.341

3.436

3.531

3.625

3.720

3.815

1750

55

MBH

18.901

21.485

24.465

27.901

31.866

36.438

41.712

47.795

KW

2.463

2.558

2.652

2.747

2.842

2.936

3.031

3.126

70

MBH

17.839

20.423

23.403

26.839

30.804

35.376

40.650

46.733

KW

2.888

2.983

3.077

3.172

3.267

3.361

3.456

3.551

80

MBH

17.166

19.750

22.730

26.166

30.131

34.703

39.977

46.060

KW

3.196

3.291

3.385

3.480

3.575

3.669

3.764

3.859

1.

These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have 
been added.

Summary of Contents for AFFINITY BHP024

Page 1: ...the installer can fit this unit between the wheel wells of full size pick up truck All models are under 500 pounds All units are completely wired charged with R 22 and tested prior to shipment Unique...

Page 2: ...er water integrity Rounded corners with water drip edges add to the attractive appearance The cabi net panels have a non fibrous insulation that reduces insulation fibers into conditioned area TOP DIS...

Page 3: ...1 leak rate Includes hood and mesh bird screen filter integrated into the hood dry bulb sensor and relief damper Sepa rate field accessories of single enthalpy and dual enthalpy are also available SIN...

Page 4: ...e designed for single point and dual con nection TABLE OF CONTENTS Description 1 Standard Features Benefits 1 Field installed Accessories 3 Unit Cut Away 5 Ratings 5 Physical Data 5 Cooling Capacities...

Page 5: ...E PHASE THREE PHASE 024 24 4 13 0 11 3 7 7 79 21 8 3 40 11 0 2 00 5 0 7 5 10 0 N A 030 30 0 13 0 11 3 7 7 77 28 2 3 40 16 5 2 20 5 0 7 5 10 0 15 0 10 0 15 0 036 35 0 13 0 11 3 7 7 77 32 0 3 30 18 9 2...

Page 6: ...R INPUT kW 2 20 2 21 2 17 2 16 2 24 2 24 2 20 2 19 Sensible Capacity MBH 1 Entering Dry Bulb F 86 19 5 21 5 20 5 20 6 20 4 22 3 20 8 20 9 83 17 2 19 2 20 5 20 6 18 5 20 7 20 8 20 9 80 14 9 16 9 19 7 2...

Page 7: ...ER INPUT kW 3 14 3 12 3 04 3 06 3 24 3 22 3 14 3 16 Sensible Capacity MBH 1 Entering Dry Bulb F 86 21 7 26 6 25 0 26 7 23 9 27 9 26 0 27 7 83 18 8 24 1 25 0 26 7 20 6 26 3 26 0 27 7 80 15 9 21 1 25 4...

Page 8: ...PUT kW 3 61 3 52 3 44 3 45 3 70 3 61 3 53 3 54 Sensible Capacity MBH 1 Entering Dry Bulb F 86 23 9 29 4 29 5 30 4 26 2 31 9 30 2 31 1 83 20 9 26 6 29 2 30 0 22 7 28 9 30 2 31 1 80 17 9 23 6 27 8 28 6...

Page 9: ...PUT kW 4 01 3 98 3 89 3 88 4 06 4 03 3 94 3 93 Sensible Capacity MBH 1 Entering Dry Bulb F 86 28 1 34 5 35 2 35 6 29 4 35 8 35 4 35 7 83 24 5 31 6 34 8 35 1 25 6 33 0 35 2 35 5 80 21 0 28 1 33 7 33 8...

Page 10: ...T kW 4 71 4 62 4 52 4 47 4 81 4 71 4 61 4 56 Sensible Capacity MBH 1 Entering Dry Bulb F 86 32 0 40 2 40 1 43 2 33 5 41 8 40 3 43 5 83 28 0 36 5 39 7 41 8 29 2 38 0 40 1 42 7 80 23 9 32 4 39 6 39 3 24...

Page 11: ...WER INPUT kW 5 64 5 52 5 37 5 28 6 17 6 04 5 88 5 77 Sensible Capacity MBH 1 Entering Dry Bulb F 86 36 7 45 7 46 8 47 2 41 9 49 9 46 3 46 7 83 32 0 41 1 46 8 47 2 35 9 45 9 46 3 46 7 80 27 3 36 4 46 7...

Page 12: ...e indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added TABLE 10 HEATING CAPACITIES 2 1 2 TON BHP030 CFM RETURN AIR F CAP1 KW OUTDOOR AIR TE...

Page 13: ...the indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added TABLE 12 HEATING CAPACITIES 3 1 2 TON BHP042 CFM RETURN AIR F CAP1 KW OUTDOOR AIR...

Page 14: ...66 3 793 4 020 4 247 4 474 80 MBH 13 394 16 579 20 504 25 342 31 304 38 653 47 709 58 871 KW 3 227 3 453 3 680 3 907 4 134 4 361 4 588 4 815 1 These capacities are net capacities the indoor motor heat...

Page 15: ...1 412 494 577 B1HP042 Cooling TB2 A Heating TB2 A 1300 CFM 338 395 470 551 640 B1HP042 Cooling TB2 B Heating TB2 B 1400 CFM 393 466 544 642 734 B1HP048 Heating TB2 A 1400 CFM 377 427 504 597 683 B1HP0...

Page 16: ...used for all field installed 24 volt wire Only required on units with supplemental electric heat PROGRAMMABLE THERMOSTAT ONLY 24 VOLT TRANSFORMER Label all wires prior to disconnection when servicing...

Page 17: ...7 31 0 6 6 8 12 7 20 20 0 96 75 042 208 230 1 60 187 253 20 0 104 0 1 1 7 3 33 4 40 40 0 96 40 208 230 3 60 187 253 13 9 88 0 1 1 7 3 25 8 30 30 0 96 75 460 3 60 414 504 6 4 44 0 0 6 7 3 16 1 20 20 0...

Page 18: ...48 7 45 50 45 50 2NH04501525 11 3 15 0 31 3 36 1 47 7 63 7 60 70 60 70 036 208 230 3 60 11 4 78 0 1 1 7 3 2NH04501025 7 5 10 0 20 8 24 1 48 7 52 7 60 60 60 60 2NH04501525 11 3 15 0 31 3 36 1 76 7 67 8...

Page 19: ...T OF UNIT CENTER OF GRAVITY B1HP UNIT SIZE SHIPPING WEIGHT OPERATING WEIGHT CORNER WEIGHTS A B C D 024 356 351 97 93 81 84 030 353 348 96 93 81 84 036 388 383 106 102 89 92 042 440 435 120 115 101 104...

Page 20: ...7 A 1205 20 Unitary Products Group FIGURE 5 UNIT DIMENSIONS 5217 5217 OO GLPHQVLRQV DUH LQ LQFKHV 7KH DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH HUWLILHG GLPHQVLRQV ZLOO EH SURYLGHG XSRQ UHTXHVW 29 5 81 7 6...

Page 21: ...036 21528 007 A 1205 Unitary Products Group 21 FIGURE 6 TYPICAL APPLICATIONS...

Page 22: ...036 21528 007 A 1205 22 Unitary Products Group FIGURE 7 ROOF CURB DIMENSIONS...

Page 23: ...036 21528 007 A 1205 Unitary Products Group 23 FIGURE 8 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY...

Page 24: ...036 21528 007 A 1205 24 Unitary Products Group FIGURE 9 TYPICAL WIRING DIAGRAM 230 3 60 POWER SUPPLY...

Page 25: ...036 21528 007 A 1205 Unitary Products Group 25 FIGURE 10 TYPICAL WIRING DIAGRAM 460 575 3 60 POWER SUPPLY...

Page 26: ...be provided to assure reliable transit of equipment overhead rig ging fork truck access and proper sealing on roof curb applications Base rails shall be removable when required to lower unit height 8...

Page 27: ...ing the normal system operation pressures C Unit shall contain a reliable demand defrost control to provide defrost The defrost control shall also have an X terminal to provide a 24 volt signal for r...

Page 28: ...Printed in U S A 036 21528 007 A 1205 Copyright by Unitary Products Group 2005 All rights reserved Supersedes 036 21528 006 A 1005 Unitary 5005 Norman Products York OK Group Drive 73069 ISO 9001 Cert...

Reviews: