background image

036-21528-007-A-1205

14

Unitary Products Group

TABLE 13: HEATING CAPACITIES - 4 TON (BHP048)

CFM

RETURN

AIR °F

CAP

1

& KW

OUTDOOR AIR TEMPERATURE, °F (72% RH)

-10

0

10

20

30

40

50

60

1200

55

MBH

13.911

17.096

21.021

25.859

31.821

39.170

48.226

59.388

KW

2.342

2.568

2.795

3.022

3.249

3.476

3.703

3.930

70

MBH

11.264

14.449

18.374

23.212

29.174

36.523

45.579

56.741

KW

2.726

2.952

3.179

3.406

3.633

3.860

4.087

4.314

80

MBH

9.676

12.861

16.786

21.624

27.586

34.935

43.991

55.153

KW

3.067

3.293

3.520

3.747

3.974

4.201

4.428

4.655

1600

55

MBH

16.349

19.534

23.459

28.297

34.259

41.608

50.664

61.826

KW

2.408

2.634

2.861

3.088

3.315

3.542

3.769

3.996

70

MBH

13.702

16.887

20.812

25.650

31.612

38.961

48.017

59.179

KW

2.792

3.018

3.245

3.472

3.699

3.926

4.153

4.380

80

MBH

12.114

15.299

19.224

24.062

30.024

37.373

46.429

57.591

KW

3.133

3.359

3.586

3.813

4.040

4.267

4.494

4.721

2000

55

MBH

17.629

20.814

24.739

29.577

35.539

42.888

51.944

63.106

KW

2.502

2.728

2.955

3.182

3.409

3.636

3.863

4.090

70

MBH

14.982

18.167

22.092

26.930

32.892

40.241

49.297

60.459

KW

2.886

3.112

3.339

3.566

3.793

4.020

4.247

4.474

80

MBH

13.394

16.579

20.504

25.342

31.304

38.653

47.709

58.871

KW

3.227

3.453

3.680

3.907

4.134

4.361

4.588

4.815

1.

These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have 
been added.

TABLE 14: HEATING CAPACITIES - 5 TON (BHP060)

CFM

RETURN

AIR °F

CAP

1

& KW

OUTDOOR AIR TEMPERATURE, °F (72% RH)

-10

0

10

20

30

40

50

60

1950

55

MBH

16.136

19.904

24.617

30.513

37.889

47.115

58.657

73.095

KW

2.403

2.771

3.140

3.509

3.877

4.246

4.615

4.983

70

MBH

15.014

18.782

23.495

29.391

36.767

45.993

57.535

71.973

KW

2.967

3.335

3.704

4.073

4.441

4.810

5.179

5.547

80

MBH

11.066

14.834

19.547

25.443

32.819

42.045

53.587

68.025

KW

3.368

3.736

4.105

4.474

4.842

5.211

5.580

5.948

2000

55

MBH

16.054

19.822

24.535

30.431

37.807

47.033

58.575

73.013

KW

2.411

2.779

3.148

3.517

3.885

4.254

4.623

4.991

70

MBH

14.932

18.700

23.413

29.309

36.685

45.911

57.453

71.891

KW

2.975

3.343

3.712

4.081

4.449

4.818

5.187

5.555

80

MBH

10.984

14.752

19.465

25.361

32.737

41.963

53.505

67.943

KW

3.376

3.744

4.113

4.482

4.850

5.219

5.588

5.956

1.

These capacities are net capacities - the indoor motor heat has been added. These power inputs are total power inputs - the indoor motor watts have 
been added.

Summary of Contents for AFFINITY BHP024

Page 1: ...the installer can fit this unit between the wheel wells of full size pick up truck All models are under 500 pounds All units are completely wired charged with R 22 and tested prior to shipment Unique...

Page 2: ...er water integrity Rounded corners with water drip edges add to the attractive appearance The cabi net panels have a non fibrous insulation that reduces insulation fibers into conditioned area TOP DIS...

Page 3: ...1 leak rate Includes hood and mesh bird screen filter integrated into the hood dry bulb sensor and relief damper Sepa rate field accessories of single enthalpy and dual enthalpy are also available SIN...

Page 4: ...e designed for single point and dual con nection TABLE OF CONTENTS Description 1 Standard Features Benefits 1 Field installed Accessories 3 Unit Cut Away 5 Ratings 5 Physical Data 5 Cooling Capacities...

Page 5: ...E PHASE THREE PHASE 024 24 4 13 0 11 3 7 7 79 21 8 3 40 11 0 2 00 5 0 7 5 10 0 N A 030 30 0 13 0 11 3 7 7 77 28 2 3 40 16 5 2 20 5 0 7 5 10 0 15 0 10 0 15 0 036 35 0 13 0 11 3 7 7 77 32 0 3 30 18 9 2...

Page 6: ...R INPUT kW 2 20 2 21 2 17 2 16 2 24 2 24 2 20 2 19 Sensible Capacity MBH 1 Entering Dry Bulb F 86 19 5 21 5 20 5 20 6 20 4 22 3 20 8 20 9 83 17 2 19 2 20 5 20 6 18 5 20 7 20 8 20 9 80 14 9 16 9 19 7 2...

Page 7: ...ER INPUT kW 3 14 3 12 3 04 3 06 3 24 3 22 3 14 3 16 Sensible Capacity MBH 1 Entering Dry Bulb F 86 21 7 26 6 25 0 26 7 23 9 27 9 26 0 27 7 83 18 8 24 1 25 0 26 7 20 6 26 3 26 0 27 7 80 15 9 21 1 25 4...

Page 8: ...PUT kW 3 61 3 52 3 44 3 45 3 70 3 61 3 53 3 54 Sensible Capacity MBH 1 Entering Dry Bulb F 86 23 9 29 4 29 5 30 4 26 2 31 9 30 2 31 1 83 20 9 26 6 29 2 30 0 22 7 28 9 30 2 31 1 80 17 9 23 6 27 8 28 6...

Page 9: ...PUT kW 4 01 3 98 3 89 3 88 4 06 4 03 3 94 3 93 Sensible Capacity MBH 1 Entering Dry Bulb F 86 28 1 34 5 35 2 35 6 29 4 35 8 35 4 35 7 83 24 5 31 6 34 8 35 1 25 6 33 0 35 2 35 5 80 21 0 28 1 33 7 33 8...

Page 10: ...T kW 4 71 4 62 4 52 4 47 4 81 4 71 4 61 4 56 Sensible Capacity MBH 1 Entering Dry Bulb F 86 32 0 40 2 40 1 43 2 33 5 41 8 40 3 43 5 83 28 0 36 5 39 7 41 8 29 2 38 0 40 1 42 7 80 23 9 32 4 39 6 39 3 24...

Page 11: ...WER INPUT kW 5 64 5 52 5 37 5 28 6 17 6 04 5 88 5 77 Sensible Capacity MBH 1 Entering Dry Bulb F 86 36 7 45 7 46 8 47 2 41 9 49 9 46 3 46 7 83 32 0 41 1 46 8 47 2 35 9 45 9 46 3 46 7 80 27 3 36 4 46 7...

Page 12: ...e indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added TABLE 10 HEATING CAPACITIES 2 1 2 TON BHP030 CFM RETURN AIR F CAP1 KW OUTDOOR AIR TE...

Page 13: ...the indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added TABLE 12 HEATING CAPACITIES 3 1 2 TON BHP042 CFM RETURN AIR F CAP1 KW OUTDOOR AIR...

Page 14: ...66 3 793 4 020 4 247 4 474 80 MBH 13 394 16 579 20 504 25 342 31 304 38 653 47 709 58 871 KW 3 227 3 453 3 680 3 907 4 134 4 361 4 588 4 815 1 These capacities are net capacities the indoor motor heat...

Page 15: ...1 412 494 577 B1HP042 Cooling TB2 A Heating TB2 A 1300 CFM 338 395 470 551 640 B1HP042 Cooling TB2 B Heating TB2 B 1400 CFM 393 466 544 642 734 B1HP048 Heating TB2 A 1400 CFM 377 427 504 597 683 B1HP0...

Page 16: ...used for all field installed 24 volt wire Only required on units with supplemental electric heat PROGRAMMABLE THERMOSTAT ONLY 24 VOLT TRANSFORMER Label all wires prior to disconnection when servicing...

Page 17: ...7 31 0 6 6 8 12 7 20 20 0 96 75 042 208 230 1 60 187 253 20 0 104 0 1 1 7 3 33 4 40 40 0 96 40 208 230 3 60 187 253 13 9 88 0 1 1 7 3 25 8 30 30 0 96 75 460 3 60 414 504 6 4 44 0 0 6 7 3 16 1 20 20 0...

Page 18: ...48 7 45 50 45 50 2NH04501525 11 3 15 0 31 3 36 1 47 7 63 7 60 70 60 70 036 208 230 3 60 11 4 78 0 1 1 7 3 2NH04501025 7 5 10 0 20 8 24 1 48 7 52 7 60 60 60 60 2NH04501525 11 3 15 0 31 3 36 1 76 7 67 8...

Page 19: ...T OF UNIT CENTER OF GRAVITY B1HP UNIT SIZE SHIPPING WEIGHT OPERATING WEIGHT CORNER WEIGHTS A B C D 024 356 351 97 93 81 84 030 353 348 96 93 81 84 036 388 383 106 102 89 92 042 440 435 120 115 101 104...

Page 20: ...7 A 1205 20 Unitary Products Group FIGURE 5 UNIT DIMENSIONS 5217 5217 OO GLPHQVLRQV DUH LQ LQFKHV 7KH DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH HUWLILHG GLPHQVLRQV ZLOO EH SURYLGHG XSRQ UHTXHVW 29 5 81 7 6...

Page 21: ...036 21528 007 A 1205 Unitary Products Group 21 FIGURE 6 TYPICAL APPLICATIONS...

Page 22: ...036 21528 007 A 1205 22 Unitary Products Group FIGURE 7 ROOF CURB DIMENSIONS...

Page 23: ...036 21528 007 A 1205 Unitary Products Group 23 FIGURE 8 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY...

Page 24: ...036 21528 007 A 1205 24 Unitary Products Group FIGURE 9 TYPICAL WIRING DIAGRAM 230 3 60 POWER SUPPLY...

Page 25: ...036 21528 007 A 1205 Unitary Products Group 25 FIGURE 10 TYPICAL WIRING DIAGRAM 460 575 3 60 POWER SUPPLY...

Page 26: ...be provided to assure reliable transit of equipment overhead rig ging fork truck access and proper sealing on roof curb applications Base rails shall be removable when required to lower unit height 8...

Page 27: ...ing the normal system operation pressures C Unit shall contain a reliable demand defrost control to provide defrost The defrost control shall also have an X terminal to provide a 24 volt signal for r...

Page 28: ...Printed in U S A 036 21528 007 A 1205 Copyright by Unitary Products Group 2005 All rights reserved Supersedes 036 21528 006 A 1005 Unitary 5005 Norman Products York OK Group Drive 73069 ISO 9001 Cert...