292443-XTG-B-0807

Unitary Products Group

5

required if Thermostat 2ET07700224 and 2ET04700224 are 
used.

MOTORIZED FRESH AIR DAMPER

 - Designed for duct 

mounted side supply/return and unit mounted down supply/
return applications. Damper capable of providing 0% through 
50% of outdoor air (field supplied). Closes on power loss, 
includes hood and screen assembly.

FILTER / FRAME KIT (Single Phase only)

 - Kit contains the 

necessary hardware to field install return air filters into the 
base unit. Pre-cut filter racks and appropriate cleanable stan-
dard size filters are shipped in one kit. The fiter rack is suit-
able for either 1” or 2” filters (1” filter is supplied). This kit is 
available for single phase horizontal or vertical duct applica-
tion only. Standard in all 3 phase models

RECTANGLE TO ROUND ADAPTERS

 - Kit includes one 

supply and one return air rectangle to round duct adapter. 
Adapters are preformed and designed to fit over current duct 
openings on the base unit. Transition is from side square duct 
opening to 14" round duct opening.

ROOF CURBS

 - NRCA approved curbs provide proper fit to 

base unit for rooftop installations. Curbs are designed to be 
assembled through hinge pins in each corner. Kit also pro-
vides seal strip to assure a water tight seal. 8 and 14 inch 
high roof curbs are available.

MANUAL OUTDOOR DAMPER

 - Provides 0% through 50% 

outdoor air capability (field adjustable). Designed for duct 
mounted side supply/return applications. Includes hood and 
screen assembly.

WALL THERMOSTAT

 - The units are designed to operate 

with 24-volt electronic and electro-mechanical thermostats. 
All units can operate with single stage heat / single stage cool 
thermostats - with or without the economizer.

LOW AMBIENT KIT

 - Kit provides necessary hardware to 

convert unit to operate in cooling cycle down to 0 F. Standard 
unit operation 45 F.

TRANSFORMER KIT

 - Kit provides necessary hardware to pro-

vide single phase models from factory furnished 40 VA trans-
former capability to 75 VA transformer capability. (Required on 
installations with economizer or motorized damper.)

FIGURE 2 -  UNIT COMPONENT LOCATION

BLOW-THROUGH DESIGN

WITH RELIABLE  ALUMINIZED

STEEL TUBULAR HEAT

EXCHANGERS

LONG-LASTING

POWDER PAINT

FINISH 

REAR & BOTTOM

RETURN AIR

AND SUPPLY AIR

DUCT OPENINGS

HEAVY GAUGE
REMOVEABLE 

BASE  RAILS

3-SPEED DIRECT DRIVE

BLOWER MOTOR WITH

SLIDE-OUT BLOWER ASSEMBLY

POWER VENTER MOTOR

HIGH VOLTAGE

TERMINAL BLOCK

AUTOMATIC

GAS VALVE

(1/2"- 14NPTI)

SELF-DIAGNOSTIC CONTROLS

WITH "COMFORT MATCH" SPEED

CONTROL

LOW VOLTAGE

TERMINAL BLOCK

HIGH GRADE 

ALUMINIZED

IN-SHOT BURNERS

PILOT ASSEMBLY

HIGH EFFICIENCY

COMPRESSOR

RIGIDLY MOUNTED

DECORATIVE

PROTECTIVE 

COIL GUARD

HIGHLY EFFICIENT

ENHANCED COPPER
TUBE/ALUMINUM FIN

CONDENSER COIL

HIGHLY EFFICIENT

ENHANCER

COPPER TUBE/ALUMINUM FIN

EVAPORATOR COIL

DIRECT  DRIVE

CONDENSER FAN

MOTOR

Summary of Contents for AFFINITY 018N03606

Page 1: ...Series packaged units are designed to han dle applications ranging from residential to light commercial and any in between The Affinity is a unit that gives you the flexibility and choices you need in...

Page 2: ...2 TON 8 5 DNA030 COOLING CAPACITIES 2 1 2 TON 9 6 DNA036 COOLING CAPACITIES 3 TON 10 7 DNA042 COOLING CAPACITIES 3 1 2 TON 11 8 DNA048 COOLING CAPACITIES 4 TON 12 9 DNA060 COOLING CAPACITIES 5 TON 13...

Page 3: ...ENSATE PAN A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate Less collection of stagnate condensate will build up The condensate...

Page 4: ...em No final field mounting required EASY SERVICE ACCESS A large single panel covers the electrical and gas controls makes servicing easy The blower compartment has an additional large panel with a bui...

Page 5: ...DOOR DAMPER Provides 0 through 50 outdoor air capability field adjustable Designed for duct mounted side supply return applications Includes hood and screen assembly WALL THERMOSTAT The units are desi...

Page 6: ...R RECIPROCATING S SCROLL R R R R R S S 1 See FILTER FRAME KIT on page 5 TABLE 2 RATINGS COOLING GAS HEATING MODEL DNA NET COOLING CAPACITY1 SOUND RATING dbels 2 GAS HEAT CAPACITY EFFICIENCIES MBH EER...

Page 7: ...1 Entering Dry Bulb F 86 9 4 11 7 13 3 13 1 10 2 12 8 14 0 13 9 11 1 13 9 14 8 14 7 11 1 14 1 15 2 15 1 11 1 14 3 15 6 15 5 83 8 5 10 9 12 9 12 9 9 3 11 9 13 8 13 8 10 1 12 9 14 8 14 7 10 3 13 3 15 2...

Page 8: ...0 16 4 18 1 18 0 14 2 17 8 18 8 18 8 15 3 19 2 19 5 19 6 15 3 19 5 19 8 19 9 15 4 19 8 20 1 20 1 83 11 9 15 2 17 7 17 5 12 9 16 5 18 6 18 6 13 9 17 8 19 5 19 6 14 3 18 4 19 8 19 9 14 6 19 0 20 1 20 1...

Page 9: ...15 9 20 0 20 6 20 1 17 7 22 3 22 5 21 9 19 6 24 7 24 4 23 8 19 5 24 9 24 7 24 0 19 5 25 1 25 0 24 3 83 14 4 18 5 20 5 19 9 16 1 20 7 22 5 21 8 17 8 22 9 24 4 23 8 18 2 23 5 24 7 24 0 18 6 24 1 25 0 24...

Page 10: ...21 1 27 2 29 8 28 8 22 4 28 7 30 6 29 5 23 7 30 3 31 3 30 2 23 2 30 1 31 7 30 6 22 8 29 8 32 1 30 9 83 19 4 25 4 29 3 28 4 20 5 26 8 30 3 29 3 21 6 28 2 31 3 30 2 21 6 28 5 31 7 30 6 21 7 28 7 32 1 3...

Page 11: ...86 23 6 29 4 31 7 31 8 25 7 32 0 33 3 33 7 27 8 34 6 34 8 35 6 28 0 35 1 35 6 36 4 28 1 35 7 36 5 37 3 83 21 5 27 3 30 9 30 9 23 4 29 7 32 9 32 9 25 3 32 1 34 8 35 0 26 1 33 2 35 6 36 2 26 8 34 4 36...

Page 12: ...6 26 7 34 8 35 7 36 0 30 1 38 1 37 2 37 5 33 4 41 5 38 8 39 1 36 1 42 5 39 2 39 5 38 8 43 6 39 7 40 0 83 23 3 31 3 35 3 35 6 26 0 34 9 37 0 37 3 28 7 38 4 38 8 39 1 30 8 40 5 39 2 39 5 32 8 42 6 39 7...

Page 13: ...b F 86 36 1 45 1 45 0 42 7 39 9 48 7 46 8 44 3 43 7 52 3 48 5 45 9 46 9 53 0 49 0 46 4 50 1 53 6 49 5 46 9 83 31 8 40 8 44 8 42 6 34 9 44 6 46 7 44 2 37 9 48 4 48 5 45 9 40 3 50 5 49 0 46 4 42 6 52 6...

Page 14: ...des allowances for a dry evaporator coil gas heat exchanger and no filters For additional pressure drops refer to Table 12 and 13 TABLE 11 BOTTOM SUPPLY AIR BLOWER PERFORMANCE1 MODEL DNA MTR SPD EXTER...

Page 15: ...s CFM during full economizer operation TABLE 13 ADDITIONAL STATIC PRESSURE RESISTANCE 4 5 TON DNA048 060 1 DESCRIPTION RESISTANCE IWG CFM 500 600 700 800 900 1 000 1 100 1 200 1 300 1 400 1 500 1 600...

Page 16: ...FACTOR TRANSFORMER SIZE VA MIN MAX RLA LRA 018 208 230 1 60 187 253 9 0 48 0 1 1 2 2 14 5 20 20 96 40 024 208 230 1 60 187 253 11 5 60 0 1 1 2 2 17 7 25 25 96 40 030 208 230 1 60 187 253 14 7 73 0 1 1...

Page 17: ...I N L E T L O U V E R S F R O N T G A S E L E C T R I C C O N T R O L S E R V I C E A C C E S S C O M P A R T M E N T P A N E L O V E R A L L O V E R A L L All dimensions are in inches They are subjec...

Page 18: ...D R A I N 3 4 N P T I G A S S U P P L Y 1 5 8 D I A K N O C K O U T 1 2 N P T I C O N N E C T I O N L O W V O L T A G E C O N N 1 8 D I A K N O C K O U T 1 3 4 1 5 2 9 9 1 6 1 5 3 1 2 1 3 4 1 3 4 1 5...

Page 19: ...L G A S S H U T O F F V A L V E R E T U R N A I R D U C T S U P P L Y A I R D U C T C O N T R O L W I R I N G T O I N D O O R T H E R M O S T A T T O P O W E R S U P P Y M A N U A L G A S S H U T O F...

Page 20: ...U N D I N S T A L L A T I O N TABLE 17 UNIT WEIGHTS AND CENTER OF GRAVITY UNIT SIZE SHIPPING WEIGHT lbs OPERATING WEIGHT lbs CORNER WEIGHTS location lbs ECONOMIZER lbs ROOF CURB lbs A B C D 018 365 3...

Page 21: ...1 8 X 2 1 1 2 R E C O M M E N D E D D U C T S I Z E 1 7 1 2 X 1 6 3 4 1 8 Roof curb also available 3 4 X 1 W I D E G A S K E T I N G F O R C U R B F R A M E A N D A L L D U C T S U P P O R T S U R F A...

Page 22: ...292443 XTG B 0807 22 Unitary Products Group FIGURE 14 TYPICAL WIRING DIAGRAM DNA 018 THRU 060 208 230 1 60 POWER SUPPLY...

Page 23: ...facility YORK s Affinity package units are designed to handle applications ranging from residential to light commercial and any in between The Affinity is a unit that gives you the flexibility and cho...

Page 24: ...Y Fan shall be direct drive multi speed design Job site selected BHP brake horsepower shall not exceed the motors nameplate horsepower rating Fan wheel shall be double inlet type with forward curved b...