5
Installation Instruction
INDOOR UNIT INSTALLATION
1.
2. Drill a hole in the wall
Fig.4
Fig.5
Note:
Fit the Installation Plate
1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete or
the like, drill eight (8) 5mm diameter holes
in the wall. Insert Clip anchor for appropriate
mounting screws.
3. Fit the installation plate on the wall with eight
(8) type “A” screws.
Correct orientation
of Installation Plate
Fit the Installation Plate and drill holes in the wall according to the wall structure
and corresponding mounting points on the installation plate.
(
Dimensions are in “mm” unless otherwise stated)
1. Determine hole positions according to
the diagram detailed in Fig.5. Drill
one (1) hole (
65mm) slanting slightly
to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate or the like.
Wall
Indoor
Outdoor
5-7mm
Fig.6
150mm or more to ceiling
Indoor unit outline
Installation plate
293
Right refrigerant
pipe hole
65
Left refrigerant
pipe hole
65
120mm or more
to wall
120mm or more
to wall
920
Above 150 from the ceiling
Hooked Part
Indoor Unit Outline
Hooked Part
Pipe hole
Above 120mm from
the wall
432
58
465
465
115
50
Pipe hole
58
50
115
Hooked Part
432
1080
Above 120mm from
the wall
330
108
22
95
95
(
21000Btu/h model)
(
21000Btu/h model)