2

Safety precautions

!

WARNING

Do not install it yourself.

Install the unit securely in a place which
can bear the weight of the unit.

Use the specified wires to connect the
indoor and outdoor units securely and
attach the wires firmly to the terminal
board connecting sections so the stress
of the wires is not applied to the sections

Incorrect installation could cause injury due to fire,

electric shock, the unit falling or leakage of water.
Consult the dealer from whom you purchased the
unit or special installer

When installed in an insufficiently strong place,

the unit could fall causing injury.

Incorrect connection and fixing could cause a fire.

If the capacity of the power circuit is insufficient

or there is incomplete electrical work, it could

result in a fire or an electric shock.

The use of defective parts could cause an injury

due to a fire, electric shock, the unit falling, etc.

Incorrect installation could cause a personnel

injury due to fire, electric shock, the unit falling
or leakage of water.

If the electrical part covers of the indoor unit

and/or the service panel of the outdoor unit
are not attached securely, it could result in a
fire or electrical shock due to dust, water, etc.

Perform electrical work according to the
installation manual and be sure to use an
exclusive circuit.

Be sure to use the part provided or
specified parts for the installation work.

Perform the installation securely referring
to the installation instruction.

Check that the refrigerant gas does not
leak after installation is completed.

Attach the electrical part cover to the indoor unit and
the service panel to the outdoor unit securely.

Be sure to read the following WARNING before installing the air

conditioner.

Be sure to observe the cautions specified here as they include

important items related to safety.

After reading this instructions, be sure to keep it together with the

owners manual in a handy place for future reference.

SAFETY PRECAUTIONS

The following should be always observed for safety:

!

CAUTIONS

Do not install the unit in a place where
a flammable gas leaks.

If gas leaks and accumulates in the area

surrounding the unit, it could cause a
explosion.

If there is a defect in the drainage/piping work,

water could leak from the unit and household
goods could get wet and be damaged.

Perform the drainage/piping work according to the
installation instruction.

Summary of Contents for 10 SEER 50HZ R22

Page 1: ...hen the power cord is damaged replacement work shall be performed by authorized personnel only Installation work must be performed in accordance with the national wiring standards by authorized person...

Page 2: ...f Improper installation will cause water leakage electrical shock or fire Please consult authorized dealer or specialist for the installation work Please note fault caused by improper installation is...

Page 3: ...f the outdoor unit are not attached securely it could result in a fire or electrical shock due to dust water etc Perform electrical work according to the installation manual and be sure to use an excl...

Page 4: ...ht or rain exposure make sure that heat radiation from the condenser is not restricted Ensure that the clearance around the back of the unit The front of the unit should have more than 200cm of cleara...

Page 5: ...left and right of the indoor unit is more than 12cm The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling Use a stud finder to locate studs to prevent unnecessary d...

Page 6: ...tructure and corresponding mounting points on the installation plate Dimensions are in mm unless otherwise stated 1 Determine hole positions according to the diagram detailed in Fig 5 Drill one 1 hole...

Page 7: ...rom side to side to see that it is securely hooked 3 Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping...

Page 8: ...se sloped downward to drain out the condensed water smoothly CAUTION Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where t...

Page 9: ...C Roughness Burr Main cause for refrigerant leakage is due to defect in the flaring work Carry out correct flaring work using the following procedure 1 Use the piping kit accessory or pipes purchased...

Page 10: ...ing Flare nut Pipings Fig 18 ELECTRICAL WORK Electric safety regulations for the initial Installation 1 If there is serious safety problem about the power supply the technicians should refuse to insta...

Page 11: ...from a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units 4 Insulate unused cords conductors with PVC tape Process them so they do not touch any electr...

Page 12: ...oad 9 The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active phase conductors CAUTION CAUTION C...

Page 13: ...Lo of the manifold valve 4 Operate the vacuum pump to evacuate After slightly loose the flare nut of the Lo valve on the gas pipe side check that the air is entering Operation noise pump changes and...

Page 14: ...safety check Gas leak check 1 Soap water method Do a leak test of all joints of the tubing both indoor and outdoor and both gas and liquid side service valves Bubbles indicate a leak 2 Leak detector...