Mechanical Installation
Part 2
Step 23
3/6
Wire Connections -
At the X Axis Gantry, connect the Flame Detector Harness. Ensure that the wire is routed away
from any rollers, using cable ties as needed.
NOTE: FLAME DETECTION
The 6550-Pro is equipped with a flame detection sensor,
which will stop the machine in the event of fire detected in
the engraving area (directly beneath the laser).
In some circumstances, such as direct sunlight, the flame
detector may trigger in error. If this is preventing machine
operation, the flame sensor may be unplugged to
continue.
Important: Unplugging the sensor will remove ALL flame
detection capability!