5-58
IM 760151-17E
:INTEGrate:RESet
Function
Resets the integrated value.
Syntax
:INTEGrate:RESet {<NRf>,<NRf>,
<NRf>,<NRf>}
<NRf>
= 1 to 4 (power measurement element
that is stopped)
Example
• Example in which the individual power
measurement element integration
(
:INTEGrate:INDependent
) is “ON (1)”
:INTEGRATE:RESET
(Stop all power measurement elements)
:INTEGRATE:RESET 1,2,3
(Specify power measurement elements and
stop)
• Example in which the individual power
measurement element integration
(
:INTEGrate:INDependent
) is “OFF (0)”
:INTEGRATE:RESET
(Stop all power measurement elements)
Description • When the individual power measurement
element integration (
:INTEGrate:
INDependent
) is “ON (1),” you can specify
up to 4 power measurement elements to be
started as parameters. However, this method
is possible only through communications.
There are no front panel keys that correspond
to this method. Omitting parameters is
equivalent to specifying all power
measurement elements.
• When the individual power measurement
element integration (
:INTEGrate:
INDependent
) is “OFF (0),” you cannot
specify parameters. If you do, an error
occurs.
:INTEGrate:RTIMe<x>?
Function
Queries the integration start and stop times for
real-time integration mode.
Syntax
:INTEGrate:RTIMe<x>?
<x> = 1 to 4 (power measurement element)
Example
:INTEGRATE:RTIME1? -> :INTEGRATE:
RTIME1:START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0
Description When the individual power measurement
element integration (
:INTEGrate:
INDependent
) is “OFF (0),” the integration
operates according to the integration start/stop
time of power measurement element 1. Queries
to other elements results in error.
:INTEGrate:RTIMe<x>:{STARt|END}
Function
Sets the integration {start
|
stop} time for real-
time integration mode or queries the current
setting.
Syntax
:INTEGrate:RTIMe<x>:{STARt|END}
{<NRf>,<NRf>,<NRf>,<NRf>,<NRf>,
<NRf>}
:INTEGrate:RTIMe<x>:{STARt|END}?
<x> = 1 to 4 (power measurement element)
{
<NRf>
,
<NRf>
,
<NRf>
,
<NRf>
,
<NRf>
,
<NRf>
} = 2001, 1, 1, 0, 0, 0 to 2099, 12, 31, 23,
59, 59
1st
<NRf>
= 2001 to 2099 (year)
2nd
<NRf>
= 1 to 12
(month)
3rd
<NRf>
= 1 to 31
(day)
4th
<NRf>
= 0 to 23
(hour)
5th
<NRf>
= 0 to 59
(minute)
6th
<NRf>
= 0 to 59
(second)
Example
:INTEGRATE:RTIME1:
START 2001,1,1,0,0,0
:INTEGRATE:RTIME1:START? ->
:INTEGRATE:RTIME1:
START 2001,1,1,0,0,0
Description When the individual power measurement
element integration (
:INTEGrate:
INDependent
) is “OFF (0),” the integration
operates according to the integration start/stop
time of power measurement element 1.
Commands and queries to other elements result
in error.
5.11 INTEGrate Group